Non-Destructive Evaluation for Sectional Loss of External Tendon of Prestressed Concrete Structures Using Total Flux Leakage
Source abstract
Abstract
A non-destructive evaluation method is proposed to identify the sectional loss of the external tendon of prestressed concrete structures by detecting the change of the magnetic flux in the external tendon exposed to a magnetic field. The method uses a solenoid-shaped device with two coils: a primary coil for producing magnetic field and secondary coil for damage detection, wrapping the external tendon. A current applied to the primary coil in the device causes the magnetic field. Then, the change in the magnetic flux by the damage in the external tendon is detected by the variation of the voltage in the secondary coil in the device as the device moves along the tendon. An alternating current is applied to the primary coil to minimize the effect of the moving speed of the device. As a result, the damaged area can be detected with a low-level energy current. In addition, a wrapping solenoid-shaped device that is easy to disassemble and assemble was developed for in situ inspection. The measured signal from the secondary coil has a sinusoidal form with the same frequency as the applied current to the primary coil, and the peak curve of the measured signal provides enough information to detect the damage. It is shown that the proposed method can quantitatively identify one or multiple damaged-tendon locations as well as damages of at least 2 cm.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Infrastructure Safety Research, Korea Institute of Civil Engineering and Building Technology, 283, Goyangdae-Ro, Goyang-Si, Gyeonggi-Do 10223, Korea
Funding
Korea Institute of Civil Engineering and Building Technology (KICT)
References (26)
Show source-provided references
1. Corrosion and strength behaviors in prestressed tendon under various tensile stress and impressed current conditions
2. Mahmoodian, M., and Li, C.Q. (2012, January 10–13). Failure assessment of a pre-stressed concrete bridge using time dependent system reliability method. Proceedings of the 29th Annual International Bridge Conference, Pittsburgh, PA, USA.
3. Forensic Examination of a Noncomposite Adjacent Precast Prestressed Concrete Box Beam Bridge10.1061/(ASCE)BE.1943-5592.0000110 ↗
4. Weiher, H., and Zilch, K. (2006, January 26–28). Condition of post-tensioned concrete bridges-assessment of the German stock by a spot survey of damages. Proceedings of the First International Conference on Advances in Bridge Engineering, Brunel University, Uxbridge, UK.
5. Present situation of durability of post-tensioned PC bridges in Japan
6. Fricker, S., and Vogel, T. (2006). Detecting wire breaks in a prestressed concrete road bridge with continuous acoustic monitoring. Bridge Maint. Saf. Manag. Life-Cycle Perform. Cost, 847–850.
7. Hurlebaus, S., Hueste, M., Karthik, M., and Terzioglu, T. (2016). Condition Assessment of Bridge Post-Tensioning and Stay Cable Systems Using NDE Methods, NCHRP, Transportation Research Board of the National Academies. NCHRP Report 14-28.10.17226/24779 ↗
8. Trejo, D., Hueste, M.B.D., and Gardoni, P. (2009). Effect of Voids in Grouted, Post-tensioned Concrete Bridge Construction: Volume 1—Electrochemical Testing and Reliability Assessment, Texas Transportation Institute, Texas A&M University. (No. FHWA/TX-09/0-4588-1 Vol. 1).
9. VDOT Experience with Grouts and Grouted Post-Tensioned Tendons
10. Yu, C., Kim, K., Seol, D., and Youn, S. (2017, January 2). Endoscope survey of internal, external tendon in PSC Box Girder. Proceedings of the Annual Conference of Korea Concrete Institute, Andong-Si, Korea.
11. Evaluation of corrosion prevention systems of strands for PSC structures10.4334/JKCI.2019.31.6.557 ↗
12. Kim, K., Youn, S., and Youn, S. (2019). Corrosion of Post-Tensioned Tendons and Technology of Grouting, Magazine of Korea Concrete Institute.
13. Adcox, S. (2020, September 07). DOT: Corrosion ‘Exploded’ Cable in Wando Bridge, Sending Grout Flying 100 Feet. The Post and Courier. Available online: https://www.postandcourier.com/politics/dot-corrosion-exploded-cable-in-wando-bridge-sending-grout-flying-100-feet/article_bfff0fa0-7568-11e8-a1a7-0bfbef6a71fe.html.
14. FHWA (2013). Guidelines for Sampling, Assessing, and Restoring Defective Grout in Prestressed Concrete Bridge Post-Tensioning Ducts.
15. Practical assessment of magnetic methods for corrosion detection in an adjacent precast, prestressed concrete box-beam bridge10.1080/10589759.2012.695785 ↗
16. Azizinamini, A., and Gull, J. (2012). Improved inspection techniques for steel prestressing/post-tensioning strand. FDOT Contract No. BDK80 977-13 Final Report-Volume I, Florida Department of Transportation, Florida International University.
17. Magnetic flux leakage technique to detect loss in metallic area in external post-tensioning systems10.1016/j.engstruct.2019.109765 ↗
18. Magnetic field techniques for the inspection of steel under concrete cover10.1016/S0963-8695(00)00051-7 ↗
19. Comprehensive MMF–MFL inspection for corrosion detection and estimation in embedded prestressing strands10.1007/s13349-013-0061-4 ↗
20. Moriya, T., Sugawara, M., and Tsukada, K. (2004, January 9–12). Magnetic nondestructive evaluation of corrosion in wire ropes. Proceedings of the Oceans ′04 MTS/IEEE Techno-Ocean ′04 (IEEE Cat. No.04CH37600), Kobe, Japan.
21. Cross-Sectional Loss Quantification for Main Cable NDE Based on the B-H Loop Measurement Using a Total Flux Sensor10.1155/2019/8014102 ↗
22. Nims, D.K., and Devabhaktuni, V. (2011). Magnetic Sensor for Nondestructive Evaluation of Deteriorated Prestressing Strand-Phase II, The University of Toledo University Transportation Center.
23. Qu, Y., Zhang, H., Zhao, R., Liao, L., and Zhou, Y. (2019). Research on the Method of Predicting Corrosion width of Cables Based on the Spontaneous Magnetic Flux Leakage. Materials, 12.10.3390/ma12132154 ↗
24. Zhao, Q., Zhou, J., Xia, Q., Zhang, S., and Zhang, H. (2019). Non-Destructive Testing of Steel Corrosion Fluctuation Parameters Based on Spontaneous Magnetic Flux Leakage and Its Relationship with Steel Bar Diameter. Materials, 12.10.3390/ma12244116 ↗
25. Sun, Z. (2008, January 12–17). Cable tension sensor based on magneto-elastic effect. Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China.
26. Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge10.1061/(ASCE)BE.1943-5592.0000421 ↗