journal article·2021-07-16Open access

A Voxel-Based Assessment of Noise Properties in Computed Tomography Imaging with the ASiR-V and ASiR Iterative Reconstruction Algorithms

Patrizio Barca, Daniela Marfisi, Chiara Marzi, Sabino Cozza, Stefano Diciotti, Antonio Claudio Traino, Marco Giannelli

Applied Sciences· Volume 11· Issue 14

Abstract

Given the inherent characteristics of nonlinearity and nonstationarity of iterative reconstruction algorithms in computed tomography (CT) imaging, this study aimed to perform, for the first time, a voxel-based characterization of noise properties in CT imaging with the ASiR-V and ASiR algorithms as compared with conventional filtered back projection (FBP). Multiple repeated scans of the Catphan-504 phantom were carried out. CT images were reconstructed using FBP and ASiR/ASiR-V with different blending levels of reconstruction (20%, 40%, 60%, 80%, 100%). Noise maps and their nonuniformity index (NUI) were obtained according to the approach proposed by the report of AAPM TG-233. For the homogeneous CTP486 module, ASiR-V/ASiR allowed a noise reduction of up to 63.7%/52.9% relative to FBP. While the noise reduction values of ASiR-V-/ASiR-reconstructed images ranged up to 33.8%/39.9% and 31.2%/35.5% for air and Teflon contrast objects, respectively, these values were approximately 60%/50% for other contrast objects (PMP, LDPE, polystyrene, acrylic, Delrin). Moreover, for all contrast objects but air and Teflon, ASiR-V showed a greater noise reduction potential than ASiR when the blending level was ≥40%. While noise maps of the homogenous CTP486 module showed only a slight spatial variation of noise (NUI < 5.2%) for all reconstruction algorithms, the NUI values of iterative-reconstructed images of the nonhomogeneous CTP404 module increased nonlinearly with blending level and were 19%/15% and 6.7% for pure ASiR-V/ASiR and FBP, respectively. Overall, these results confirm the potential of ASiR-V and ASiR in reducing noise as compared with conventional FBP, suggesting, however, that the use of pure ASiR-V or ASiR might be suboptimal for specific clinical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Dose and Imaging · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, 56126 Pisa, Italy

Department of Electrical, Electronic and Information Engineering “Guglielmo Marconi”, University of Bologna, 47522 Cesena, Italy

Department of Radiology, Azienda USL Toscana Nord Ovest, 56025 Pontedera, Italy

References (72)

Show source-provided references
1. Computed Tomography—An Increasing Source of Radiation Exposure10.1056/NEJMra072149 ↗
2. Boone, J.M., Brink, J.A., Edyvean, S., Huda, W., Leitz, W., McCollough, C.H., and McNitt-Gray, M.F. (2012). Report 87. J. ICRU, 12.10.1093/jicru/ndt006 ↗
3. Radiation Exposure in CT Scanning and Risk: Where Are We?10.1148/radiol.12121137 ↗
4. Smith-Bindman, R., Wang, Y., Chu, P., Chung, R., Einstein, A.J., Balcombe, J., Cocker, M., Das, M., Delman, B.N., and Flynn, M. (2019). International Variation in Radiation Dose for Computed Tomography Examinations: Prospective Cohort Study. BMJ, k4931.10.1136/bmj.k4931 ↗
5. Cumulative Exposure to Ionising Radiation from Diagnostic Imaging Tests: A 12-Year Follow-up Population-Based Analysis in Spain10.1136/bmjopen-2019-030905 ↗
6. Andersson, J., Pavlicek, W., Al-Senan, R., Cody, D., Dixon, R., Columbo, P., Dong, F., Edyvean, S., Jansen, J., and Kanal, K. (2019). Estimating Patient Organ Dose with Computed Tomography: A Review of Present Methodology and Required DICOM Information. A Joint Report of AAPM Task Group 246 and the European Federation of Organizations for Medical Physics (EFOMP), AAPM.10.37206/190 ↗
7. Patients Undergoing Recurrent CT Scans: Assessing the Magnitude10.1007/s00330-019-06523-y ↗
8. Patient Organ and Effective Dose Estimation in CT: Comparison of Four Software Applications10.1186/s41747-019-0130-5 ↗
9. European Commission, and Directorate-General for Energy (2015). Medical Radiation Exposure of the European Population, Publications Office of the European Union. Radiation Protection.
10. National Council on Radiation Protection and Measurements (2019). Medical Radiation Exposure of Patients in the United States: Recommendations of the National Council on Radiation Protection and Measurements, National Council on Radiation Protection and Measurements. NCRP Report.
11. AAPM/RSNA Physics Tutorial for Residents. Topics in CT: Radiation Dose in CT10.1148/rg.226025128 ↗
12. State of the Art: Technologies for Computed Tomography Dose Reduction10.1007/s10140-009-0850-6 ↗
13. Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction Algorithm10.2214/AJR.09.2953 ↗
14. CT Radiation Dose: Current Controversies and Dose Reduction Strategies10.2214/AJR.12.9720 ↗
15. Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study10.2214/AJR.09.2397 ↗
16. Radiation Dose Reduction with Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography10.1097/RCT.0b013e31825586c0 ↗
17. Objective Assessment of Image Quality and Dose Reduction in CT Iterative Reconstruction: Validating Dose Reduction Claims for CT Iterative Reconstruction10.1118/1.4881148 ↗
18. CT Radiation Dose and Iterative Reconstruction Techniques10.2214/AJR.14.13241 ↗
19. Iterative Reconstruction Methods in X-Ray CT10.1016/j.ejmp.2012.01.003 ↗
20. Iterative Reconstruction Techniques for Computed Tomography Part 1: Technical Principles10.1007/s00330-012-2765-y ↗
21. State of the Art: Iterative CT Reconstruction Techniques10.1148/radiol.2015132766 ↗
22. Basics of Iterative Reconstruction Methods in Computed Tomography: A Vendor-Independent Overview10.1016/j.ejrad.2018.10.025 ↗
23. Abdominal CT with Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose with Standard-Dose Imaging10.2214/AJR.12.9382 ↗
24. Iterative Reconstruction Methods in Two Different MDCT Scanners: Physical Metrics and 4-Alternative Forced-Choice Detectability Experiments—A Phantom Approach10.1016/j.ejmp.2011.12.004 ↗
25. Iterative Reconstruction Techniques for Computed Tomography Part 2: Initial Results in Dose Reduction and Image Quality10.1007/s00330-012-2764-z ↗
26. Chen, J.-H., Jin, E.-H., He, W., and Zhao, L.-Q. (2014). Combining Automatic Tube Current Modulation with Adaptive Statistical Iterative Reconstruction for Low-Dose Chest CT Screening. PLoS ONE, 9.10.1371/journal.pone.0092414 ↗
27. Model-Based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT10.1148/radiol.13130362 ↗
28. A Study of the Image Quality of Computed Tomography Adaptive Statistical Iterative Reconstructed Brain Images Using Subjective and Objective Methods10.1093/rpd/ncw084 ↗
29. Assessment of the Dose Reduction Potential of a Model-Based Iterative Reconstruction Algorithm Using a Task-Based Performance Metrology10.1118/1.4903899 ↗
30. Performance Evaluation of Iterative Reconstruction Algorithms for Achieving CT Radiation Dose Reduction—A Phantom Study10.1120/jacmp.v17i2.5709 ↗
31. A Noise Power Spectrum Study of a New Model-Based Iterative Reconstruction System: Veo 3.010.1120/jacmp.v17i5.6225 ↗
32. Image Quality with Iterative Reconstruction Techniques in CT of the Lungs—A Phantom Study10.1016/j.ejro.2018.02.002 ↗
33. Computed Tomography Imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) Algorithm: Dependence of Image Quality on the Blending Level of Reconstruction10.1007/s13246-018-0645-8 ↗
34. The Evolution of Image Reconstruction for CT—From Filtered Back Projection to Artificial Intelligence10.1007/s00330-018-5810-7 ↗
35. Technical Note: Impact on Central Frequency and Noise Magnitude Ratios by Advanced CT Image Reconstruction Techniques10.1002/mp.13937 ↗
36. Hsieh, J. (2008). Adaptive Statistical Iterative Reconstruction. White Papper GE Healthcare.
37. Fan, J., Yue, M., and Melnyk, R. (2014). Benefits of ASiR-V Reconstruction for Reducing Patient Radiation Dose and Preserving Diagnostic Quality in CT Exams. White Papper GE Healthcare.
38. Thibault, J.-B. (2010). Veo CT Model-Based Iterative Reconstruction. White Papper GE Healthcare.
39. Towards Task-Based Assessment of CT Performance: System and Object MTF across Different Reconstruction Algorithms10.1118/1.4725171 ↗
40. Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels10.1148/radiol.15142047 ↗
41. Hsieh, J. (2015). Computed Tomography: Principles, Design, Artifacts, and Recent Advances, SPIE PRESS.10.1117/3.2197756 ↗
42. A Three-Dimensional Statistical Approach to Improved Image Quality for Multislice Helical CT10.1118/1.2789499 ↗
43. A Qualitative and Quantitative Analysis of Radiation Dose and Image Quality of Computed Tomography Images Using Adaptive Statistical Iterative Reconstruction10.1120/jacmp.v17i3.5903 ↗
44. Quantitative Analysis of the Effect of Iterative Reconstruction Using a Phantom: Determining the Appropriate Blending Percentage10.3349/ymj.2015.56.1.253 ↗
45. The Adaptive Statistical Iterative Reconstruction-V Technique for Radiation Dose Reduction in Abdominal CT: Comparison with the Adaptive Statistical Iterative Reconstruction Technique10.1259/bjr.20150463 ↗
46. Adaptive Statistical Iterative Reconstruction-V: Impact on Image Quality in Ultralow-Dose Coronary Computed Tomography Angiography10.1097/RCT.0000000000000460 ↗
47. Technical Note: Evaluation of a 160-Mm/256-Row CT Scanner for Whole-Heart Quantitative Myocardial Perfusion Imaging10.1118/1.4957389 ↗
48. Objective Task-Based Assessment of Low-Contrast Detectability in Iterative Reconstruction10.1093/rpd/ncw020 ↗
49. Head CT: Image Quality Improvement with ASIR-V Using a Reduced Radiation Dose Protocol for Children10.1007/s00330-017-4733-z ↗
50. Adaptive Statistical Iterative Reconstruction–V versus Adaptive Statistical Iterative Reconstruction: Impact on Dose Reduction and Image Quality in Body Computed Tomography10.1097/RCT.0000000000000677 ↗
51. Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction–V) a Comparison with Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions10.1097/RCT.0000000000000666 ↗
52. Initial Phantom Study Comparing Image Quality in Computed Tomography Using Adaptive Statistical Iterative Reconstruction and New Adaptive Statistical Iterative Reconstruction V
53. Assessment of Noise Reduction Potential and Image Quality Improvement of a New Generation Adaptive Statistical Iterative Reconstruction (ASIR-V) in Chest CT10.1259/bjr.20170521 ↗
54. A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential10.2214/AJR.17.19102 ↗
55. New Adaptive Statistical Iterative Reconstruction ASiR-V: Assessment of Noise Performance in Comparison to ASiR10.1002/acm2.12253 ↗
56. Effects of Various Generations of Iterative CT Reconstruction Algorithms on Low-Contrast Detectability as a Function of the Effective Abdominal Diameter: A Quantitative Task-Based Phantom Study10.1016/j.ejmp.2018.04.006 ↗
57. Image Quality Comparison of Two Adaptive Statistical Iterative Reconstruction (ASiR, ASiR-V) Algorithms and Filtered Back Projection in Routine Liver CT10.1259/bjr.20170655 ↗
58. Clinical Value of a New Generation Adaptive Statistical Iterative Reconstruction (ASIR-V) in the Diagnosis of Pulmonary Nodule in Low-Dose Chest CT10.1259/bjr.20180909 ↗
59. Low-Dose CT Angiography Using ASiR-V for Potential Living Renal Donors: A Prospective Analysis of Image Quality and Diagnostic Accuracy10.1007/s00330-019-06423-1 ↗
60. International Atomic Energy Agency (2012). Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications, IAEA.
61. European Commission (2013). Criteria for Acceptability of Medical Radiological Equipment Used in Diagnostic Radiology, Nuclear Medicine and Radiotherapy, Publications Office of the European Union. Radiation Protection.
62. Dance, D.R. (2014). Diagnostic Radiology Physics: A Handbook for Teachers and Students, International Atomic Energy Agency. STI/PUB.
63. The Noise Power Spectrum in Computed X-Ray Tomography10.1088/0031-9155/23/3/008 ↗
64. A Simple Approach to Measure Computed Tomography (CT) Modulation Transfer Function (MTF) and Noise-Power Spectrum (NPS) Using the American College of Radiology (ACR) Accreditation Phantom10.1118/1.4800795 ↗
65. Samei, E., Bakalyar, D., Boedeker, K., Brady, S., Fan, J., Leng, S., Myers, K., Popescu, L., Ramirez-Giraldo, J.C., and Ranallo, F. (2019). Performance Evaluation of Computed Tomography Systems—The Report of AAPM Task Group 233, AAPM.10.37206/186 ↗
66. The Phantom Laboratory (2013). Catphan ® 504 Manual, The Phantom Laboratory.
67. Statistical Model Based Iterative Reconstruction (MBIR) in Clinical CT Systems: Experimental Assessment of Noise Performance10.1118/1.4867863 ↗
68. Quantum Noise Properties of CT Images with Anatomical Textured Backgrounds across Reconstruction Algorithms: FBP and SAFIRE10.1118/1.4893497 ↗
69. Characteristic Image Quality of a Third Generation Dual-Source MDCT Scanner: Noise, Resolution, and Detectability10.1118/1.4923172 ↗
70. Image Quality Assessment of an Iterative Reconstruction Algorithm Applied to Abdominal CT Imaging10.1016/j.ejmp.2014.02.005 ↗
71. Dose Reduction in 64-Row Whole-Body CT in Multiple Trauma: An Optimized CT Protocol with Iterative Image Reconstruction on a Gemstone-Based Scintillator10.1259/bjr.20160003 ↗
72. Characterization of Adaptive Statistical Iterative Reconstruction Algorithm for Dose Reduction in CT: A Pediatric Oncology Perspective10.1118/1.4745563 ↗