journal article·2021-12-27Open access

Field Test for a Base Isolation Structure on Condition of Horizontal and Initial Displacement

Ying-Xiong Wu, Xin-Jun Dong, You-Qin Lin, Hao-De Cheng

Applied Sciences· Volume 12· Issue 1

Abstract

There are a few isolated structures that have been subjected to seismic testing. An isolated structure is incapable of tracking, adjusting, and controlling its dynamic characteristics. As a result, field evaluations of solitary structures’ dynamic characteristics are important. The horizontal initial displacement of a base isolation kindergarten made of 46 isolation bearings is 75 mm. The method for creating the horizontal initial displacement condition is illustrated, as are the primary test findings. Horizontal initial displacement is accomplished with the assistance of a reaction wall, rods, and hydraulic pump system. To begin, we removed the building using hydraulic jacks to produce horizontal displacement of the isolation layer and then attached rods to support the building. The rods were then shot and unloaded, causing the building to shake freely, and its dynamic response and other parameters were tested. The results indicate that the natural vibration period of an isolated structure is much greater than the natural vibration period of a seismic structure. The isolation layer’s hysteretic curve as completely filled; upon unloading, the isolation layer as promptly reset; the dynamic response control effect of each was visible, but the top floor’s acceleration was magnified by approximately 1.27 times.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Seismic Performance and Analysis · Structural Engineering and Vibration Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civil Engineering, Fuzhou University, Fuzhou 350108, China

Fujian Provincial Key Laboratory on Multi-Disasters Prevention and Mitigation in Civil Engineering, Fuzhou 350108, China

References (32)

Show source-provided references
1. Nagarajaiah, S., and Sun, X.H. (1996). Seismic perfomance od base isolated buildings in the 1994 northridge earthquake. Proceedings of the 11th World Conference on Earthquake Engineering, Acapulco, Mexico, 1–6 August 1996, Pergamon. Paper No. 598.
2. Naeim, F., and Kelly, J.M. (1999). Design of Seismic Isolation Structure: From Theory to Practice, John Wiley & Sons.10.1002/9780470172742 ↗
3. Fu, J.H. (2011). Design Method for Seismic and Isolation Structures in Japan, China Architecture & Building Press.
4. The Japan Society of Seicmic Isolation (1995). Introduction to Isolation Structures, Ohmsha Press.
5. Investigation on main dynamic characteristics of base-isolated structures under ambient excitation
6. Architectural Institute of Japan (2020). Structural Design Concepts for Seismically Isolated Buildings against Extreme Ground Motions, Architectural Institute of Japan.
7. Vibration test of a high-rise building and seismic performance analysis
8. Bettinali, F., Forni, M., and Indirli, M. (1991, January 22). In-situ dynamic tests of a large seismically isolated building. Proceedings of the Interntional Meeting on Earthquake Protection of Buildings, Ancona, Italy.
9. Forni, M., Martelli, A., and Spadoni, B. (1991, January 22). Dynamic tests on seismically isolated structure mock-ups and validation of numerical models. Proceedings of the International Meeting on Earthquake Protection of Buildings, Ancona, Italy.
10. Braga, F., Laterza, M., and Gigliotti, R. (2001, January 2–5). Seismic isolation using slide and rubber bearings: Large amplitude free vibration tests on the Rapolla residence building. Proceedings of the 7th International Seminar on Seismic Isolation, Assisi, Italy.
11. Repeatable dynamic release tests on a base-isolated building10.1080/13632460109350398 ↗
12. Field testing of low-rise base isolated building10.1016/j.engstruct.2004.06.002 ↗
13. Study on test of dynamic characteristics for avibration isolation building
14. He, Y.M. (2013). Dynamic Field Test for A Base-Isolated High-Rise Steel Building Structure. [Master’s Thesis, Institute of Engineering Mechanics, China Earthquake Administration].
15. GB 50011-2010 (2016). Code for Seismic Design of Buildings, China Architecture & Building Press.
16. Optimal vulcanization of unbonded fiber reinforced elastomeric isolator devices
17. Optimal vulcanization of tires: Experimentation on idealized NRPB natural and poly-butadiene rubber blends, phenomenological smoothed numerical kinetic model and FE implementation10.1016/j.polymertesting.2018.09.030 ↗
18. Analysis of optimal placement of rubber isolated bearins in District E of the Guangdong Science Center
19. The effect of ground motion vertical component on the seismic response of historical masonry buildings: The case study of the Banloc Castle in Romania10.1016/j.engstruct.2021.113346 ↗
20. GB 20688.3-2006 (2006). Rubber Bearings-Part 3: Elastomeric Seismic-Protection Isolators for Buildings, Standards Press of China.
21. A multi-scale attention neural network for sensor location selection and nonlinear structural seismic response prediction10.1016/j.compstruc.2021.106507 ↗
22. Lead-rubber hysteretic bearing suitable for protecting structures during earthquake10.1002/eqe.4290100408 ↗
23. Derivendt, C., and Guillaume, P. (2006, January 2–6). Operational modal analysis in the presence of unknown arbitrary loads using transmissibility measurements. Proceedings of the 13th International Congress on Sound and Vibration, Viennal, Austria.
24. Vibration response transmissibility and operationalmodal analysis methods: A review and comparative study
25. Experimental study and numerical model calibration for earthquake-induced collapse of RC frames with emphasis on key columns, joints and the overall structure10.1080/13632469.2015.1040897 ↗
26. Analytical modeling of moderately ductile RC frame structures for seismic performance evaluation using PERFORM-3D10.1193/081016EQS131M ↗
27. Computer and Structures, Inc. (2006). PERFORM-3D Nonlinear Analysis and Performance Assessment for 3D Structures USER GUIDE, University of California. [4rd ed.].
28. The Japan Society of Seismic Isolation (2012). Guidelines for the Wind-resistant Design of Seismically Based-isolated Buildings, The Japan Society of Seismic Isolation.
29. Dynamic characteristics of a base isolated building from ambient vibration measurements and low level earthquake shaking10.1016/S0267-7261(02)00208-7 ↗
30. Seismic velocity changes in the eqicentral region of the 2013 Lushan earthquake measured from ambient seismic noise
31. Takeuchi, T., and Wada, A. (2017). Buckling-Restrained Braces and Applications, The Japan Society of Seismic Isolation.
32. The Japan Society of Seismic Isolation (2020). Design Guidelines for Joints of Base Isolated Members, The Japan Society of Seismic Isolation. [3rd ed.].