Electro-Mechanical Impedance Technique for Assessing the Setting Time of Steel-Fiber-Reinforced Mortar Using Embedded Piezoelectric Sensor
Source abstract
Abstract
The electro-mechanical impedance (EMI) change in Piezoelectric (PZT) sensors embedded in steel-fiber-reinforced mortar (SFRM) was investigated to assess the material setting time. The EMI was continuously monitored for 12 h by the PZT sensor embedded in SFRM having fiber volume fraction of 0.5%, 1.5%, and 2.0%. The initial and final setting time of the SFRM were estimated using EMI signal change. The penetration resistance test, a conventional test method for the setting time of cement mortar, was also conducted. In the penetration resistance test, it was observed that the initial and the final setting time of SFRM accelerated as the volume fraction of the steel fiber increased. On the other hand, in the EMI sensing technique, the initial and the final setting time of the SFRM were consistent regardless of the fiber volume fraction.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Structural Health Monitoring Techniques · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Architecture, Seowon University, Cheongju 28674, Korea
Department of Architectural Engineering, Chungbuk National University, Cheongju 28644, Korea
References (16)
Show source-provided references
1. Christensen, B.J. (2006). Time of Setting-Significance of Tests and Properties of Concrete and Concrete-Making Materials, ASTM International.
2. (2016). Standard Test Method for Time of Setting of Hydraulic Cements by Vicat Needle (Standard No. ASTM C 191-16).
3. (2016). Standard Test Method for Time of Setting of Concrete Mixtures by Penetration Resistance (Standard No. ASTM C 403/C 403M-16).
4. Investigation of setting process of cementitious materials using electromechanical impedance of embedded piezoelectric patch10.5345/JKIBC.2012.12.6.607 ↗
5. Electro-mechanical impedance based monitoring for the setting of cement paste using piezoelectricity sensor10.12989/sss.2016.17.1.123 ↗
6. Ikeda, T. (1996). Fundamentals of Piezoelectricity, Oxford University Press.
7. Use of Piezoelectric Actuators as Elements of Intelligent Structures10.2514/3.9792 ↗
8. An impedance method for dynamic analysis of active material systems10.1177/1045389X9700800405 ↗
9. Piezoelectric sensor based nondestructive active monitoring of strength gain in concrete10.1088/0964-1726/17/5/055002 ↗
10. Application of electro-mechanical impedance sensing technique for online monitoring of strength development in concrete using smart PZT patches10.1016/j.conbuildmat.2008.02.017 ↗
11. Monitoring the Strength Development in Concrete by EMI Sensing Technique10.1016/j.conbuildmat.2010.02.014 ↗
12. Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete10.1088/0964-1726/14/4/026 ↗
13. Concrete early-age strength monitoring using embedded piezoelectric transducers10.1088/0964-1726/15/6/038 ↗
14. Monitoring of the strength gain of concrete using embedded PZT impedance transducer10.1016/j.conbuildmat.2011.04.020 ↗
15. (2021). Portland Cement (Standard No. KS L 5201).
16. (2021). Methods of Testing Cements-Determination of Strength (Standard No. KS L ISO 679).