journal article·2022-08-07Open access

Analysis of Dynamic Behavior of ParReEx Robot Used in Upper Limb Rehabilitation

Daniela Tarnita, Ionut Daniel Geonea, Doina Pisla, Giuseppe Carbone, Bogdan Gherman, Nicoleta Tohanean, Paul Tucan, Cristian Abrudan, Danut Nicolae Tarnita

Applied Sciences· Volume 12· Issue 15

Abstract

This paper presents a dynamic analysis of the ParReEx multibody mechanism, which has been designed for human wrist joint rehabilitation. The starting point of the research is a virtual prototype of the ParReEx multibody mechanism. This model is used to simulate the dynamics of the multibody mechanism using ADAMS in three simulation scenarios: (a) rigid kinematic elements without friction in joints, (b) rigid kinematic elements with friction in joints, and (c) kinematic elements as deformable solids with friction in joints. In all three cases, the robot is used by a virtual patient in the form of a mannequin. Results such as the connecting forces in the kinematic joints and the torques necessary to operate the ParReEx robot modules are obtained by dynamic simulation in MSC.ADAMS. The torques obtained by numerical simulation are compared with those obtained experimentally. Finite element structural optimization (FEA) of the flexion/extension multibody mechanism module is performed. The results demonstrate the operational safety of the ParReEx multibody mechanism, which is structurally capable of supporting the external loads to which it is subjected.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Stroke Rehabilitation and Recovery · Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Mechanics, University of Craiova, 200512 Craiova, Romania

Research Center for Industrial Robots Simulation and Testing CESTER, Technical University of Cluj-Napoca, 400641 Cluj-Napoca, Romania

Department of Mechanical, Energy and Management Engineering DIMEG, University of Calabria, 87036 Cosenza, Italy

Department of Neurology, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania

Emergency Hospital of Dolj County, 200528 Craiova, Romania

Funding

Romanian Ministry of Research and Innovation · European Social Fund through the Human Capital Operational Program 2014–2020

References (51)

Show source-provided references
1. Three-dimensional, task-specific robot therapy of the arm after stroke: A multicentre, parallel-group randomised trial10.1016/S1474-4422(13)70305-3 ↗
2. World stroke organization (WSO): Global stroke fact sheet 201910.1177/1747493019881353 ↗
3. Global Burden of Stroke10.1161/CIRCRESAHA.116.308413 ↗
4. Heart disease and stroke statistics-2020 update: A report from the Americanheart association10.1161/CIR.0000000000000757 ↗
5. Recovery after stroke10.1136/jnnp.46.1.5 ↗
6. Probability of regaining dexterity in the flaccid upper limb: Impact of severity of paresis and the time since onset in acute stroke10.1161/01.STR.0000087172.16305.CD ↗
7. Home-based computer assisted arm rehabilitation robotic device for upper limb exercise after stroke: Result of feasibility study in home setting10.1186/1743-0003-11-163 ↗
8. The global burden of stroke: Persistent and disabling10.1016/S1474-4422(19)30030-4 ↗
9. Neuro-rehabilitation after stroke
10. The impact of physical therapy on functional outcomes after stroke: What’s the evidence?10.1191/0269215504cr843oa ↗
11. Robotic exoskeletons: A perspective for the rehabilitation of arm coordination in stroke patients
12. Research and development of compact wrist rehabilitation robot system10.3233/BME-130792 ↗
13. Advances in upper limb stroke rehabilitation: A technology push10.1007/s11517-011-0797-0 ↗
14. Robotic Devices as Therapeutic and Diagnostic Tools for Stroke Recovery10.1001/archneurol.2009.182 ↗
15. Gaggioli, A., Keshner, E.A., Weiss, P.L., and Riva, E. (2009). Robotic Assistance for Upper Extremity Training after Stroke. Advanced Technologies in Rehabilitation, IOS Press.
16. Design and evaluation of RUPERT wearable upper extremity exoskeleton robot for clinical and in home therapies10.1109/TSMC.2015.2497205 ↗
17. Innovative development of a spherical parallel robot for upper limb rehabilitation10.1504/IJMRS.2018.096302 ↗
18. Pisla, D., Tarnita, D., Tucan, P., Tohanean, N., Vaida, C., Geonea, I.D., Bogdan, G., Abrudan, C., Carbone, G., and Plitea, N. (2021). A Parallel Robot with Torque Monitoring for Brachial Monoparesis Rehabilitation Tasks. Appl. Sci., 11.10.3390/app11219932 ↗
19. Geonea, I.D., Tarnita, D., Pisla, D., Carbone, G., Bolcu, A., Tucan, P., Georgescu, M., and Tarniță, D.N. (2021). Dynamic Analysis of a Spherical Parallel Robot Used for Brachial Monoparesis Rehabilitation. Appl. Sci., 11.10.3390/app112411849 ↗
20. Analysis of a hand arm system10.1016/j.rcim.2013.06.001 ↗
21. Gull, M.A., Bai, S., and Bak, T. (2020). A Review on Design of Upper Limb Exoskeletons. Robotics, 9.10.3390/robotics9010016 ↗
22. Effects of robot-assisted therapy for the upper limb after stroke10.1177/1545968316666957 ↗
23. Effects of robot assistive upper extremity rehabilitation on motor and cognitive recovery, the quality of life, and activities of daily living in stroke patients10.3233/BMR-171015 ↗
24. Is robot-assisted therapy effective in upper extremity recovery in early stage stroke?—A systematic literature review10.1589/jpts.29.1108 ↗
25. Differences in muscle activity and fatigue of the upper limb between Task-Specific training and robot assisted training among individuals post stroke10.1016/j.jbiomech.2019.04.005 ↗
26. Bian, H., Chen, Z., Wang, H., and Zhao, T. (2017, January 17–20). Mechanical design of EFW Exo II: A hybrid exoskeleton for elbow-forearm-wrist rehabilitation. Proceedings of the 2017 International Conference on Rehabilitation Robotics (ICORR), London, UK.10.1109/ICORR.2017.8009328 ↗
27. Design and evaluation of a new exoskeleton for gait rehabilitation10.5194/ms-8-307-2017 ↗
28. Tarnita, D., Geonea, I., Petcu, A., and Tarnita, D.N. (2016). Numerical simulations and experimental human gait analysis using wearable sensors. International Workshop on Medical and Service Robots, Springer.10.1007/978-3-319-59972-4_21 ↗
29. About an experimental approach used to determine the kinematics of the human movement10.4028/www.scientific.net/SSP.166-167.45 ↗
30. Static and Dynamic Analysis of Osteoarthritic and Orthotic Human Knee10.1007/s42235-019-0042-3 ↗
31. Tarnita, D., Catana, M., Dumitru, N., and Tarnita, D.N. (2016). Design and simulation of an orthotic device for patients with osteoarthritis. New Trends in Medical and Service Robots, Springer.10.1007/978-3-319-23832-6_6 ↗
32. State-of-the-Art Robotic Devices for Wrist Rehabilitation: Design and Control Aspects10.1109/THMS.2020.2976905 ↗
33. Robot-Aided Neurorehabilitation: A robot for wrist rehabilitation10.1109/TNSRE.2007.903899 ↗
34. MIT-MANUS: A workstation for manual therapy and training II
35. A Wrist extension for MIT-MANUS10.1007/10946978_24 ↗
36. Robot-aided assessment of wrist proprioception10.3389/fnhum.2015.00198 ↗
37. Design and validation of the RiceWrist-S exoskeleton for robotic rehabilitation after incomplete spinal cord injury10.1017/S0263574714001490 ↗
38. Design, development and deployment of a hand/wrist exoskeleton for home-based rehabilitation after stroke—SCRIPT project10.1017/S0263574714002288 ↗
39. Solution-region-based synthesis approach for selecting optimal four-bar linkages with the Ball–Burmester point10.5194/ms-10-25-2019 ↗
40. Comparison of human–robot interaction torque estimation methods in a wrist rehabilitation exoskeleton10.1007/s10846-018-0786-8 ↗
41. The optimal speed for cortical activation of passive wrist movements performed by a rehabilitation robot: A functional NIRS study10.3389/fnhum.2017.00194 ↗
42. Design and performance analysis of a parallel wrist rehabilitation robot (PWRR)10.1016/j.robot.2019.103390 ↗
43. Design issues for an inherently safe robotic rehabilitation device10.1007/978-3-319-61276-8_110 ↗
44. A recursive formula for the inverse of the inertia matrix of a parallel manipulator10.1016/S0094-114X(97)00105-5 ↗
45. Codourey, A., and Burdet, E. (1997, January 25). A body oriented method for finding a linear form of the dynamic equatiojns of fully parallel robot. Proceedings of the International Conference on Robotics and Automation, Albuquerque, NM, USA.
46. Closed-form dynamic equations of the general Stewart platform through the Newton–Euler approach10.1016/S0094-114X(97)00087-6 ↗
47. Tucan, P., Gherman, B., Major, K., Vaida, C., Major, Z., Plitea, N., Carbone, G., and Pisla, D. (2020). Fuzzy Logic-Based Risk Assessment of a Parallel Robot for Elbow and Wrist Rehabilitation. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17020654 ↗
48. Experimental Characterization of Human Walking on Stairs Applied to Humanoid Dynamics10.1007/978-3-319-49058-8_32 ↗
49. Gherman, B., Pisla, D., Plitea, N., Vaida, C., Carbone, G., Pisla, A., and Banica, A. (2017). Parallel Robotic System for Upper Limb Medical Recovery. (Patent Number OSIM: 132,234).
50. Review and Comparison of Dry Friction Force Models10.1007/s11071-015-2485-3 ↗
51. Determination of Body Segment Parameters10.1177/001872086300500508 ↗