journal article·2017-12-19Open access

Estimation of Tendon Force Distribution in Prestressed Concrete Girders Using Smart Strand

Keunhee Cho, Sung Kim, Jeong-Rae Cho, Young-Hwan Park

Applied Sciences· Volume 7· Issue 12

Abstract

The recently developed smart strand offers the possibility of measuring the prestress force of the tendon from jacking and all along its service life. In the present study, a method estimating the force distribution in all the tendons of a prestressed concrete (PSC) girder installed with one smart strand is proposed. The force distribution in the prestressed tendons is formulated by the friction and the anchorage slip, and is obtained through an optimization process with respect to the compatibility conditions and equilibrium of the forces in the section of the PSC girder. The validation of the proposed method through a numerical example and experiment shows that it can be used to estimate the force developed in the tendon.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Fiber Optic Sensors · Structural Health Monitoring Techniques · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Structural Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology, 283, Goyangdae-Ro, Ilsanseo-Gu, Goyang-Si 10223, Gyeonggi-Do, Korea

Funding

Korea Institute of Civil and Building Technology

References (16)

Show source-provided references
1. A sensor-type pc strand with an embedded FBG sensor for monitoring prestress forces10.3390/s150101060 ↗
2. Kim, J.-M., Kim, C.-M., Choi, S.-Y., and Lee, B.Y. (2017). Enhanced strain measurement range of an FBG sensor embedded in seven-wire steel strands. Sensors, 17.10.3390/s17071654 ↗
3. A smart steel strand for the evaluation of prestress loss distribution in post-tensioned concrete structures10.1177/1045389X09347021 ↗
4. First-time demonstration of measuring concrete prestress levels with metal packaged fibre optic sensors10.1088/0964-1726/25/9/095051 ↗
5. High stress monitoring of prestressing tendons in nuclear concrete vessels using fibre-optic sensors10.1016/j.nucengdes.2013.12.038 ↗
6. Recommendations for estimating prestress losses
7. AASHTO (2014). Aashto LRFD Bridge Design Specifications, AASHTO.
8. European Committee for Standardization (2004). Eurocode 2: Design of Concrete Structures—Part 1-1: General Rules and Rules for Buildings, European Committee for Standardization. European Standards.
9. Integrated optical fiber sensing system by combing large-scale distributed botda/r and localized FBGs10.1155/2012/804394 ↗
10. Cho, K., Cho, J.-R., Kim, S.T., Park, S.Y., Kim, Y.-J., and Park, Y.-H. (2016). Estimation of prestress force distribution in multi-strand system of prestressed concrete structures using field data measured by electromagnetic sensor. Sensors, 16.10.3390/s16081317 ↗
11. Chandoga, M., and Jaroševič, A. (2005, January 28–30). Rehabilitation and monitored prestressing of corroded tendons. Proceedings of the Fib Symposium: Structural Concrete and Time, La Plata, Argentina.
12. Estimation of prestress force distribution in the multi-strand system of prestressed concrete structures10.3390/s150614079 ↗
13. Flexural strength of prestressed concrete sections by programmable calculator10.15554/pcij.01011979.32.54 ↗
14. Cho, K., Kim, S.T., Cho, J.-R., and Park, Y.-H. (2017). Analytical model of nonlinear stress-strain relation for a strand made of two materials. Materials, 10.10.3390/ma10091003 ↗
15. The effect of prestress force magnitude and eccentricity on the natural bending frequencies of uncracked prestressed concrete beams10.1016/j.jsv.2015.11.047 ↗
16. Noble, D., Nogal, M., O’Connor, A., and Pakrashi, V. (2015). The Effect of Post-Tensioning Force Magnitude and Eccentricity on the Natural Bending Frequency of Cracked Post-Tensioned Concrete Beams, IOP Publishing.10.1088/1742-6596/628/1/012047 ↗