Spectral Domain Optical Coherence Tomography Imaging Performance Improvement Based on Field Curvature Aberration-Corrected Spectrometer
Source abstract
Abstract
We designed and fabricated a telecentric f-theta imaging lens (TFL) to improve the imaging performance of spectral domain optical coherence tomography (SD-OCT). By tailoring the field curvature aberration of the TFL, the flattened focal surface was well matched to the detector plane. Simulation results showed that the spot in the focal plane fitted well within a single pixel and the modulation transfer function at high spatial frequencies showed higher values compared with those of an achromatic doublet imaging lens, which are commonly used in SD-OCT spectrometers. The spectrometer using the TFL had an axial resolution of 7.8 μm, which was similar to the theoretical value of 6.2 μm. The spectrometer was constructed so that the achromatic doublet lens was replaced by the TFL. As a result, the SD-OCT imaging depth was improved by 13% (1.85 mm) on a 10 dB basis in the roll-off curve and showed better sensitivity at the same depth. The SD-OCT images of a multi-layered tape and a human palm proved that the TFL was able to achieve deeper imaging depth and better contrast. This feature was seen very clearly in the depth profile of the image. SD-OCT imaging performance can be improved simply by changing the spectrometer’s imaging lens. By optimizing the imaging lens, deeper SD-OCT imaging can be achieved with improved sensitivity.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Optical Coherence Tomography Applications · Retinal and Macular Surgery · Glaucoma and retinal disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics, Chosun University, Gwangju 61452, Korea
Medical Photonics Research Center, Korea Photonics Technology Institute, Gwangju 61007, Korea
Funding
the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP)
References (36)
Show source-provided references
1. Optical coherence tomography10.1126/science.1957169 ↗
2. Reproducibility of optical coherence tomography airway imaging10.1364/BOE.6.004365 ↗
3. Optical coherence tomography of the esophagus and proximal stomach in health and disease10.1111/j.1572-0241.2001.04119.x ↗
4. Intravascular optical coherence tomography10.1364/BOE.8.002660 ↗
5. Three-dimensional imaging of ureter with endoscopic optical coherence tomography10.1016/j.urology.2010.11.044 ↗
6. Optical coherence tomography microangiography for monitoring the response of vascular perfusion to external pressure on human skin tissue10.1117/1.JBO.19.5.056003 ↗
7. Spectroscopic optical coherence tomography10.1364/OL.25.000111 ↗
8. Three dimensional polarization sensitive OCT of human skin in vivo10.1364/OPEX.12.003236 ↗
9. OCT elastography: Imaging microscopic deformation and strain of tissue10.1364/OE.3.000199 ↗
10. Submillimeter optical reflectometry10.1109/50.32387 ↗
11. 400-Hz mechanical scanning optical delay line10.1364/OL.18.000558 ↗
12. Optical coherence tomography using a frequency-tunable optical source10.1364/OL.22.000340 ↗
13. High-speed optical frequency-domain imaging10.1364/OE.11.002953 ↗
14. High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter10.1364/OL.28.001981 ↗
15. High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second10.1364/BOE.2.002770 ↗
16. Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr 4+: Forsterite laser10.1364/OL.22.001704 ↗
17. Wavelength-tuning interferometry of intraocular distances10.1364/AO.36.006548 ↗
18. “Coherence radar” and” spectral radar”-new tools for dermatological diagnosis10.1117/1.429899 ↗
19. Multi-MHz retinal OCT10.1364/BOE.4.001890 ↗
20. Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering10.1109/TMI.2011.2182618 ↗
21. Real-time 3D and 4D Fourier domain Doppler optical coherence tomography based on dual graphics processing units10.1364/BOE.3.002162 ↗
22. Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length10.1364/OE.22.002632 ↗
23. High-resolution optical coherence tomography over a large depth range with an axicon lens10.1364/OL.27.000243 ↗
24. Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range10.1364/OL.33.001696 ↗
25. Energy-efficient low-Fresnel-number Bessel beams and their application in optical coherence tomography10.1364/OL.39.000548 ↗
26. Depth-enhanced 2-D optical coherence tomography using complex wavefront shaping10.1364/OE.22.007514 ↗
27. Depth enhancement in spectral domain optical coherence tomography using bidirectional imaging modality with a single spectrometer10.1117/1.JBO.21.7.076005 ↗
28. Li, P., An, L., Lan, G., Johnstone, M., Malchow, D.S., and Wang, R.K. (2013). Extended imaging depth to 12 mm for 1050-nm spectral domain optical coherence tomography for imaging the whole anterior segment of the human eye at 120-kHz A-scan rate. J. Biomed. Opt., 18.10.1117/1.JBO.18.1.016012 ↗
29. Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography10.1364/OL.28.002201 ↗
30. Increasing the imaging depth of spectral-domain OCT by using interpixel shift technique10.1364/OE.14.007014 ↗
31. Improved spectral optical coherence tomography using optical frequency comb10.1364/OE.16.004163 ↗
32. Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer10.1364/OL.32.003525 ↗
33. Design of a k-space spectrometer for ultra-broad waveband spectral domain optical coherence tomography10.1038/srep42353 ↗
34. Characterization of spectral-domain OCT with autocorrelation interference response for axial resolution performance10.1364/OE.26.007253 ↗
35. Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation10.1364/OPEX.12.002404 ↗
36. Optical Design Method of a Spectrometer for Spectral Domain Optical Coherence Tomography10.3938/NPSM.68.570 ↗