journal article·2021-02-01Open access

Measurement Method for Fluid Pressure Fluctuation in Fluid-Conveying Pipe Using PVDF Piezoelectric Film Sensor

Song Liu, Xianmei Wu, Yuanyuan Kong, Xiuqian Peng

Applied Sciences· Volume 11· Issue 3

Abstract

As a representative fluid-transporting system, fluid-conveying pipes play an essential role in many fields. For a fluid-conveying pipe system in operation, fluid pulsation in pipes contains much information about fluid flow parameters (flow velocity, fluid pressure, etc.). Therefore, the measurement of fluid pulsation is important for understanding the internal fluid flow. To use polyvinylidene fluoride (PVDF) piezoelectric film sensors to indirectly measure the pressure fluctuation of the internal fluid, we simulated a fluid-conveying pipe with PVDF piezoelectric film sensors attached to the outer pipe wall. The simulation results showed that the variation of voltage signal of PVDF, circumferential stress and strain of the pipe wall, and the pressure fluctuation of internal fluid were highly positively correlated, which proved that the PVDF piezoelectric film sensor can be applied to indirectly measure the pressure fluctuation of internal fluid. We also studied the influences of flow velocity pulsation and mechanical vibration caused by the pipeline pump during operation. It is found that the flow velocity pulsation had little influence on the measurements of the variation of circumferential stress and strain of the pipe wall and the internal fluid pressure fluctuation. When both ends of the pipe were fixed by hoops, mechanical vibration had little influence on the measurement of the variation of circumferential stress and strain of the pipe wall as well as the fluid pressure fluctuation. Finally, simulation results were verified by experiments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration and Dynamic Analysis · Flow Measurement and Analysis · Fluid Dynamics and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China

University of Chinese Academy of Sciences, Beijing 100049, China

National Supercomputer Center in Tianjin, Tianjin 300457, China

References (21)

Show source-provided references
1. Wang, T. (2011). Dynamic Analysis and Vibration Control Analysis of Liquid-Conveying Pipe System Based on ANSYS Workbench, Hebei University of Science & Technology.
2. A stress analysis of a compressor blade in partially blocked inlet condition10.1177/0954410015601149 ↗
3. Aerodynamic and Structural Design of A High Efficiency Small Scale Composite V ertical Axis Wind Turbine Blade
4. Optimal design of impeller for centrifugal compressor under the influence of one-way fluid-structure interaction10.1007/s12206-016-0807-0 ↗
5. Design Optimization of A Small Scale High Expansion Ratio Organic Vapour Turbo Expander for Automotive Application10.1016/j.egypro.2017.09.185 ↗
6. Effects of blade thickness on hydraulic performance and structural dynamic characteristics of high-power coolant pump at overload condition10.1177/0957650918764729 ↗
7. Chen, X. (2015). Study on the Dynamic Characteristics of Hydraulic Flexible Pipe Fluid-Structure Coupling Vibration, Hunan University of Science and Technology.
8. Dai, Z. (2017). Vibration Analysis of L Type Hydraulic Bellows Based on Fluid Solid Coupling, Hunan University of Science and Technology.
9. Numerical simulation for effects of pipeline internal flow on vibration of flexible marine pipe
10. Numerical solution of fluid-structure interaction in liquid-filled pipes by method of characteristics
11. Nan, B., Lchiki, M., Ueno, N., Fukuda, O., and Akiyama, M. (2007, January 5–8). A flexible piezoelectric film sensor for fault diagnosis of pipe systems. Proceedings of the 33rd IEEE Annual Conference on Industrial Electronics Society, Taipei, Taiwan.
12. Liang, R., and Wang, Q.M. (2014, January 3–6). Pulse pressure sensor based on flexible PZT thick-film composite device. Proceedings of the 2014 IEEE International Ultrasonics Symposium, Chicago, IL, USA.
13. A novel sensor for measuring the acoustic pressure in buried plastic water pipes10.1016/j.jsv.2006.01.032 ↗
14. Vibration-based leak detection and monitoring of water pipes using output-only piezoelectric sensors10.1140/epjst/e2019-800150-6 ↗
15. Okosun, F., Celikin, M., and Pakrashi, V. (2020). A Numerical Model for Experimental Designs of Vibration-Based Leak Detection and Monitoring of Water Pipes Using Piezoelectric Patches. Sensors, 20.10.3390/s20236708 ↗
16. Ni, Z. (1986). Vibration Mechanics, Xi’an Jiaotong University Press.
17. Strength analysis of a large centrifugal dredge pump case10.1016/j.engfailanal.2008.05.015 ↗
18. Simplified model of the turbine runner blade10.1016/j.engfailanal.2009.04.012 ↗
19. Cook, R.D. (2002). Concepts and Applications of Finite Element Analysis, John Wiley & Sons.
20. Research on spillover effects for vibration control of piezoelectric smart structures by ANSYS
21. Subgrid-Scale Stress Modelling Based on the Square of the Velocity Gradient Tensor10.1023/A:1009995426001 ↗