Performance Evaluation of Rigid Braced Indirect Suspended Ceiling with Steel Panels
Source abstract
Abstract
In Korea, the earthquakes in Gyeongju (2016) and Pohang (2017) have led to increased interest in the seismic design of nonstructural elements. Among these, the suspended ceiling can cause personal injury and property damage. In addition, most suspended ceilings that are used in Korea neither have seismic design details nor meet the current seismic design standards. There are two seismic design methods for suspended ceilings using a perimeter clip and a brace. In the United States and Japan, seismic design of ceilings is typically used, but the concepts of applying and installing braces are different. This is because the typical ceiling systems are different in the United States and Japan. In this study, a brace-applied ceiling system that is suitable for a suspended ceiling with a steel panel was applied in the indirect suspended ceiling mainly used in Korea. In addition, the seismic performance was verified through a shaking table test. All the specimens were applied with anti-falling clips that are designed to prevent the panels from falling, and they satisfy KDS 41 17 00, which is a Korean seismic design life safety standard. Without considering these factors, the performance level is lower than a nonseismic designed ceiling, which is not properly designed or constructed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Architectural Engineering, Ajou University, Suwon 16499, Korea
Funding
Architecture and Urban Development Research Program funded by the Ministry of Land, Infrastructure, and Transport of the Korean government.
References (11)
Show source-provided references
1. Korea Design Standard (KDS) (2019). Seismic Design Code of Buildings (KDS 41 17 00: 2019), Korean Design Standard.
2. American Society of Civil Engineers (ASCE) (2016). ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures, ASCE.
3. ASTM E580/E580M (2017). Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels in Areas Subject to Earthquake Ground Motions, ASTM International.
4. (2013). Recommendation for A Seismic Design and Construction of Nonstructural Elements, Architectural Institute of Japan.
5. Earthquake Simulator Testing and Seismic Evaluation of Suspended Ceilings10.1061/(ASCE)1076-0431(2010)16:2(63) ↗
6. Seismic demand and capacity assessment of suspended ceiling systems10.1016/j.engstruct.2019.05.034 ↗
7. Performance evaluation of suspended ceiling systems using shake table test10.12989/sem.2016.58.1.121 ↗
8. Lee, J., In, S., Jung, D., Lee, S., Cho, B., Lee, J., In, S., Jung, D., Lee, S., and Cho, B. (2019, January 22–23). In Proceedings of the 4th International Workshop on the Seismic Performance of Non-Structural Elements (SPONSE) Shaking-Table Evaluation of Seismic Performance of Suspended Steel-Panel Ceiling 2019, Pavia, Italy.
9. (2015). Korean Industrial Standards (KS), KS D 3609, Steel Furrings for Wall and Ceiling in Buildings, Korean Standards Association.
10. (2010). ICC Evaluation Service, LLC, ICC-ES AC156, Acceptance Criteria for Seismic Certification by Shake-Table Testing of Non-Structural Components and Systems, International Code Council.
11. Gilani, A., Shakhzod, T., and Tedesco, L. (2014, January 21–25). Proposed new approach for the seismic evaluation testing of suspended ceiling systems, Network for Earthquake Engineering Simulation (NEES). Proceedings of the Tenth US National Conference on Earthquake Engineering Frontiers of Earthquake Engineering, Anchorage, AK, USA.