Experimental & FEM Analysis of Orthodontic Mini-Implant Design on Primary Stability
Source abstract
Abstract
The main objective of this research is to establish a connection between orthodontic mini-implant design, pull-out force and primary stability by comparing two commercial mini-implants or temporary anchorage devices, Tomas®-pin and Perfect Anchor. Mini-implant geometric analysis and quantification of bone characteristics are performed, whereupon experimental in vitro pull-out test is conducted. With the use of the CATIA (Computer Aided Three-dimensional Interactive Application) CAD (Computer Aided Design)/CAM (Computer Aided Manufacturing)/CAE (Computer Aided Engineering) system, 3D (Three-dimensional) geometric models of mini-implants and bone segments are created. Afterwards, those same models are imported into Abaqus software, where finite element models are generated with a special focus on material properties, boundary conditions and interactions. FEM (Finite Element Method) analysis is used to simulate the pull-out test. Then, the results of the structural analysis are compared with the experimental results. The FEM analysis results contain information about maximum stresses on implant–bone system caused due to the pull-out force. It is determined that the core diameter of a screw thread and conicity are the main factors of the mini-implant design that have a direct impact on primary stability. Additionally, stresses generated on the Tomas®-pin model are lower than stresses on Perfect Anchor, even though Tomas®-pin endures greater pull-out forces, the implant system with implemented Tomas®-pin still represents a more stressed system due to the uniform distribution of stresses with bigger values.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes · dental development and anomalies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
Department of Orthodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
Practice Limited to Orthodontics, 75000 Tuzla, Bosnia and Herzegovina
References (34)
Show source-provided references
1. Miniscrews in orthodontic treatment review and analysis of published clinical trials10.1016/j.ajodo.2008.01.027 ↗
2. Mechanical Stability of Novel Orthodontic Mini-Implant Designs: Part 210.2319/031011-176.1 ↗
3. Redžepagić-Vražalica, L., Mešić, E., Pervan, N., Hadžiabdić, V., Delić, M., and Glušac, M. (2021). Impact of Implant Design and Bone Properties on the Primary Stability of Orthodontic Mini-Implants. Appl. Sci., 11.10.3390/app11031183 ↗
4. Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading10.2319/070209-369.1 ↗
5. Temporary anchorage device isertions variables: Effects on retention10.2319/070309-376.1 ↗
6. Primary Migration of a Mini-Implant Under a Functional Orthodontic Loading10.1007/s00784-013-1045-9 ↗
7. Impact od Implant Design on Primary Stability of Orthodontic Mini-implants10.1007/s00056-008-0727-4 ↗
8. Identification of bone quality in conjuction with insertion of titanium implants. A pilot study in jaw authopsy specimens10.1034/j.1600-0501.1995.060403.x ↗
9. Mini-Implant Stability at the Initial Healing Period: A Clinical Pilot Study10.2319/040813-271.1 ↗
10. Influence of Different Implant Materials on the Primary Stability of Orthodontic Mini-Implants10.1016/j.kjms.2012.04.037 ↗
11. Mechanical properties of self-drilling orthodontic micro implants with different diamters10.2319/103009-607.1 ↗
12. Finite Element Analysis of Mono-and Biocortical Mini-Implant Stability10.1093/ejo/cjt023 ↗
13. Effect of Mini-Implant Length and Diameter on Primary Stability under Loading with Two Force Levels10.1093/ejo/cjq088 ↗
14. Impact of Mini-Implant Length on Stability at the Initial Healing Period: A Controled Study10.1186/1746-160X-9-30 ↗
15. Effect of Mini-Implant Diameter on Fracture Risk and Self-Drilling Efficacy10.1016/j.ajodo.2011.06.016 ↗
16. Stress Analysis of External Fixator Based on Stainless Steel and Composite Material
17. A three dimensional finite element study on dental implant design10.1016/j.jgeb.2011.05.007 ↗
18. Biomechanical and historigical comparison of self-drilling and self tapping orthodontic microimplants in dog10.1016/j.ajodo.2007.01.023 ↗
19. Predrilling of the Implant Site: Is it Necessary for Orthodontic Mini-Implants?10.1016/j.ajodo.2008.06.038 ↗
20. Temporary anchorage device stability: An evaluation of thread shape factor10.1093/ejo/cjr026 ↗
21. Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography10.1016/j.ajodo.2007.06.013 ↗
22. Miniscrew stability evaluated with computerized tomography scanning10.1016/j.ajodo.2008.03.024 ↗
23. Accuracy of a Cone Beam Computed Tomography-Guided Surgical Stent Mini-Implant Placement10.2319/060811-374.1 ↗
24. Computed Tomographic Characterization of Mini-Implant Placement Pattern and Maximum Anchorage Force in Human Cadavers10.1016/j.ajodo.2010.05.024 ↗
25. Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analysis10.1016/j.orthres.2004.11.002 ↗
26. Cicciu, M., Cervino, G., Milone, D., and Risitano, G. (2019). FEM analysis od Dental-Implant-Abutment Interface Overdenture Components and Parametric Evaluation of Equator®, and Locator® Prosthodontics Attachments. Materials, 12.10.3390/ma12040592 ↗
27. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases prei-implant stress and strin under oblique loading10.1034/j.1600-0501.2001.120614.x ↗
28. Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value10.4047/jap.2011.3.1.10 ↗
29. To Evaluate the Infuence of Different Implant Thread Designs on Stress Distribution of Osseointegrated Implant: A Three-Dimensional Finite-Element Analysis Study—An In Vitro Study10.1055/s-0040-1709218 ↗
30. Numerical analysis in the dental implants: Case of three implants
31. Maxillary Posterior Intrusion Mechanics with Mini-Implant Anchorage Evaluated with the Finite Element Method10.1016/j.ajodo.2011.06.019 ↗
32. Stress Distribustion in Dental Implant with Elastomeric Stress Barrier10.1016/j.matdes.2010.05.053 ↗
33. Functionality Evaluation of a novel Smart Expendable Pedicle Screw to Mitigate Osteoporosis Effect in Bone Fixation: Modeling an Experimentation
34. The Influence of Implant Body and Thread Design of Mini Dental Implants on the Loading of Surrounding Bone: A Finite Element Analysis10.1515/bmt-2016-0002 ↗