Study on the Variable Speed Diesel Generator and Effects on Structure Vibration Behavior in the DC Grid
Source abstract
Abstract
Global warming and air pollutants are in general major worldwide concerns including for the marine shipping industry. Equipped with new technologies, the onboard DC grid has proven several advantages, including up to 27% reduction in specific fuel consumption with reduced emissions. That can be achieved by installing an optimized variable speed diesel generator. The engine speed is adjusted according to the required power, which allows to always keep the best efficiency of the combustion process. However, it also exposes some changes in the behavior of the structure vibrations. Measurements on an experimental variable speed diesel generator show that vibration increases when trying to slow down the engine for the same load. This behavior is closely related to the resonance in low rev range that usually occurs with general gensets. In other words, we can conclude that the DC grid’s variable speed generator may be beneficial for fuel efficiency, but not for mechanical life and safety. Several measures had been given, of which the alternation of the natural frequency is presented as an economical and efficient solution. The ultimate goal is to maintain operational safety while respecting reduced fuel consumption.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Maritime Transport Emissions and Efficiency · Advanced Combustion Engine Technologies · Engineering Applied Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Marine System Engineering, Korea Maritime and Ocean University, Busan 49112, Korea
Interdisciplinary Major of Maritime AI Convergence, Korea Maritime and Ocean University, Busan 49112, Korea
Funding
National Research Foundation of Korea · Ministry of Trade, Industry and Energy
References (23)
Show source-provided references
1. Advantages of using a DC power system on board ship10.18048/2016.52.05 ↗
2. (2021, September 02). Onboard DC Grid—A System Platform at the Heart of Shipping 4.0. Available online: https://new.abb.com/marine/generations/generations-2017/business-articles/onboard-dc-grid-a-system-platform-at-the-heart-of-shipping.
3. (2021, September 02). Variable Speed Generators Sets Offer Advantages for Commercial Shipping. Available online: https://www.mtu-solutions.com/cn/en/technical-articles/2020/variable-speed-generator-sets-offer-advantages-for-commercial-sh.html.
4. DC-grid system for ships: A study of benefits and technical considerations
5. Next-Generation Shipboard DC Power System: Introduction Smart Grid and dc Microgrid Technologies into Maritime Electrical Networks10.1109/MELE.2016.2544203 ↗
6. Progressing towards DC electrical systems for marine vessels10.1016/j.egypro.2017.12.643 ↗
7. Generation control system for improving design and stability of medium-voltage DC power systems on ships10.1049/iet-est.2011.0016 ↗
8. International Electrotechnical Commission (2021, September 02). LVDC: Electricity for the 21st Century. Available online: https://storage-iecwebsite-prd-iec-ch.s3.eu-west-1.amazonaws.com/2019-09/content/media/files/tr_lvdc_en_2017_lr.pdf.
9. Design and control of hybrid power and propulsion systems for smart ships: A review of developments10.1016/j.apenergy.2017.02.060 ↗
10. (2021, September 02). The Step Forward Onboard DC Grid the New Way with Onboard DC Grid. Available online: https://new.abb.com/docs/librariesprovider91/articles/lm00614-onboard-dc-grid-brochure_june2014_1.pdf.
11. The Effect of Some Engine Variables on Ignition Delay and Other Combustion Phenomena in a Diesel Engine
12. Ignition Delay in Diesel Engines
13. Engine performance and optimum injection timing for 4-cylinder direct injection hydrogen fueled engine10.1016/j.simpat.2010.10.006 ↗
14. Barnes, T.E., and Uhlenhake, B.E. (2002). Method of Determining the Fuel Injection Timing for an Internal Combustion Engine. (6,367,456), U.S. Patent.
15. Hountalas, D.T., Raptotasios, S., Antonopoulos, A.K., Daniolos, S., Dolaptzis, I., and Tsobanoglou, M. (2014, January 25–27). Two-Stroke Marine Diesel Engine Variable Injection Timing System Performance Evaluation and Optimum Setting for Minimum Fuel Consumption at Acceptable NOx Levels. Proceedings of the ASME 2014 12th Biennial Conference on Engineering Systems Design and Analysis, Copenhagen, Denmark.10.1115/ESDA2014-20528 ↗
16. (2021, September 02). Wärtsilä Variable Injection Timing. Available online: https://www.wartsila.com/services-catalogue/engine-services-4-stroke/wartsila-variable-injection-timing.
17. (2021, September 02). Variable Injection Timing (VIT): What Marine Engineers Must Know?. Available online: https://www.marineinsight.com/main-engine/vit-marineengineer-must-know/.
18. (2017). ISO 8528-9:2017 Reciprocating Internal Combustion Engine Driven Alternating Current Generating Sets—Part 9: Measurement and Evaluation of Mechanical Vibrations, International Organization for Standardization.
19. (2021, September 02). Antoine Parseval (1755–1836)—Biography—MacTutor History of Mathematics. Available online: https://mathshistory.st-andrews.ac.uk/Biographies/Parseval/.
20. Arfken, G.B., Weber, H.J., and Harris, F.E. (2013). Mathematical Methods for Physicists, Elsevier Inc.
21. (2021, September 02). Parseval’s Theorem. Available online: https://en.wikipedia.org/wiki/Parseval%27s_theorem.
22. Tan, L., and Jiang, J. (2018). Digital Signal Processing: Fundamentals and Applications, Elsevier.
23. An Overview of Methods of Re-duction of Vibration for Diesel Generators