journal article·2023-04-17Open access

Seismic Benefits from Coupling Frame Structures with a Hysteretic Mass Damper Inerter

Angelo Di Egidio, Alessandro Contento

Applied Sciences· Volume 13· Issue 8

Abstract

The coupling of frame structures with external oscillating bodies, such as rigid walls, dynamic mass absorbers, elastoplastic dampers, or tuned mass dampers, can be effective in reducing the displacements of the structure and protecting it against seismic loads. This paper proposes connecting an external oscillating body to the first story of a frame structure and studying the effectiveness of the coupling by evaluating the reduction in the displacements of the frame structure. The inertial effects of the oscillating body are increased by introducing a virtual mass, provided by an inerter device. The oscillating body, characterized by physical and virtual masses, is connected to the frame structure through a hysteretic device. The study is performed on a dynamically equivalent three-degree-of-freedom (3-DOF) model, whose equations are written using a direct approach. To verify the effectiveness of the protection device, named hysteretic mass damper inerter (HMDI), in reducing the displacements of the frame structure, the displacement of the first story and the drifts of the upper stories are compared to those of the frame structure not connected to the external oscillating body. An initial spectral analysis, performed on the linearized mechanical system, clarifies the role of the parameters of the external device in the dynamic behavior of the coupled system. An additional seismic analysis is performed by using three single earthquake records first, and then a set of seven additional earthquake records selected to be compatible with the design spectrum of Los Angeles. Specific spectral gain maps are used to organize the results of an extensive parametric analysis. They show that the HMDI reduces both displacements and drifts of the structure in large ranges of the parameters that characterize the HMDI. It is found that the proposed protection method is particularly effective for low- and medium-rise frame structures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Seismic Performance and Analysis · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil, Construction-Architectural and Environmental Engineering, University of L’Aquila, 67100 L’Aquila, Italy

College of Engineering, Fuzhou University, Fuzhou 350025, China

References (42)

Show source-provided references
1. Base isolation: Linear theory and design10.1193/1.1585566 ↗
2. Den Hartog, J.P. (1956). Mechanical Vibrations, McGraw-Hill. [4th ed.].
3. Parametric analysis and simplified design of tuned mass damper10.1016/S0141-0296(97)00078-3 ↗
4. On tuned mass dampers for reducing the seismic response of structures10.1002/eqe.461 ↗
5. The effect of tuned-mass dampers on the seismic response of base-isolated structures10.1016/0020-7683(94)00150-U ↗
6. Effect of tuned mass damper on displacement demand of base-isolated structures10.1016/j.engstruct.2008.05.027 ↗
7. Dynamics of Rocking Podium Structures10.1002/eqe.2915 ↗
8. A half-century of rocking isolation10.12989/eas.2014.7.6.1187 ↗
9. The dynamics of an elastic structure coupled with a rocking wall10.1002/eqe.2838 ↗
10. Combined use of rocking wall and inerters to improve the seismic response of frame structures
11. Seismic performance of frame structures coupled with an external rocking wall10.1016/j.engstruct.2020.111207 ↗
12. Rigid block coupled with a 2 d.o.f. system: Numerical and experimental investigation
13. Seismic benefits of deformable connections between a frame structure and an external structure with inerter
14. Di Egidio, A., Pagliaro, S., and Contento, A. (2022). Elasto-plastic short exoskeleton to improve dynamic and seismic performances of frame structures. Appl. Sci., 12.10.3390/app122010398 ↗
15. Pole placement method to control the rocking motion of rigid blocks
16. Protection from overturning of rigid block-like objects with linearquadratic regulator active control
17. Top disconnection versus base disco nnection in structures subjected to harmonic base excitation10.1016/j.engstruct.2017.09.041 ↗
18. Tuned mass damper and base isolation: A unitary approach for the seismic protection of conventional frame structures10.1061/(ASCE)EM.1943-7889.0001581 ↗
19. Analytical and experimental studies on midstory isolated buildings with modal coupling effect10.1002/eqe.2203 ↗
20. Archetype dynamically equivalent 3-d.o.f. model to evaluate seismic performances of intermediate discontinuity in frame structures10.1061/(ASCE)EM.1943-7889.0002083 ↗
21. Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems10.1016/j.probengmech.2014.03.007 ↗
22. Inerter-like devices used for vibration isolation: A historical perspective10.1016/j.jfranklin.2020.11.007 ↗
23. Benefits of the inerter in vibration suppression of a milling machine10.1016/j.jfranklin.2019.02.002 ↗
24. A novel rotational inertia damper for amplifying fluid resistance: Experiment and mechanical model10.1016/j.ymssp.2020.107313 ↗
25. Experimental seismic performance assessment and numerical modelling of nonlinear inerter vibration absorber (IVA)-equipped base isolated structures tested on shaking table10.1002/eqe.3469 ↗
26. Novel type of tuned mass damper with inerter which enables changes of inertance10.1016/j.jsv.2015.03.035 ↗
27. Optimal design and performance evaluation of systems with Tuned Mass Damper Inerter (TMDI)10.1002/eqe.2861 ↗
28. An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI)10.1002/eqe.3011 ↗
29. Soil-dependent optimum design of a new passive vibration control system combining seismic base isolation with tuned inerter damper10.1016/j.soildyn.2017.11.023 ↗
30. Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria10.1002/stc.2082 ↗
31. A generalized 2-DOF model for optimal design of MDOF structures controlled by Tuned Mass Damper Inerter (TMDI)10.1016/j.ijmecsci.2020.105849 ↗
32. Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings10.1016/j.jfranklin.2018.11.012 ↗
33. Design and performance evaluation of inerter-based tuned mass dampers for a ground acceleration excited structure10.1016/j.soildyn.2020.106463 ↗
34. Di Egidio, A., and Contento, A. (2022). Improvement of the dynamic and seismic behaviour or rigid block-like structures with a hysteretic mass damper coupled with an inerter. Appl. Sci., 127.10.3390/app122211527 ↗
35. Method for random vibration of hysteretic systems
36. Parameter Analysis of the Differential Model of Hysteresis
37. Constantinou, M., and Adnane, M. (1987). Dynamics of Soil-Base-Isolated Structure Systems Report 4: Evaluation of Two Models for Yielding Systems, Department of Civil Engineering, Drexel University. Report to NSAF.
38. Seismic Protection of Structures with Supplemental Rotational Inertia10.1061/(ASCE)EM.1943-7889.0001152 ↗
39. Seismic protection of rocking structures with inerters
40. Chopra, A.K. (1995). Dynamics of Structures, Prentice Hall, Inc.
41. Viola, E. (2001). Fondamenti di Dinamica e Vibrazione delle Strutture, 1st Volume, Pitagora Editrice Bologna.
42. REXEL: Computer aided record selection for code-based seismic structural analysis10.1007/s10518-009-9146-1 ↗