journal article·2023-11-01Open access

Effect of Curing Time and Nitrogen Generator Usage on Direct 3D-Printed Aligners Thicknesses—An In Vitro Micro-CT Study

Marco Migliorati, Sara Drago, Alberto Lagazzo, Alessandra Campobasso, Giovanni Battista, Robert Kerberger, Dieter Drescher, Kathrin Becker

Applied Sciences· Volume 13· Issue 21

Abstract

Many variables in the production of direct 3D-printed orthodontic aligners are currently tested to obtain an efficient and safe workflow. The aim of the present study was to investigate the effect of different curing times on the final thickness of the produced aligners. In total, 35 copies of the same aligner with a set thickness of 0.5 mm were directly 3D printed using the instructions provided by the manufacturer. Seven groups (five aligners each) were created. Six groups were post-cured with a nitrogen generator for, respectively, 15 min, 20 min, 25 min, 30 min, 40 min, and 50 min. The last group was cured for 30 min without the nitrogen generator. All aligners were scanned with a micro-CT scanner. To assess local aligner thickness values, a total of 20 reference points were utilised. The comparisons among groups and locations were performed using ANOVA or the Kruskal–Wallis test. Significant differences in thickness were found at various reference points. No impact on curing time was found. No direct association was found between curing time and thicknesses, nor between nitrogen generator usage and thickness. At a 60° printing inclination and following the prescribed centrifugation process, a local thickness increase on the front teeth was observed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental materials and restorations · Anatomy and Medical Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Surgical Sciences and Integrated Diagnostics (DISC), School of Medical and Pharmaceutical Sciences, Genova University, 16126 Genoa, Italy

Section of Materials Engineering, Department of Civil, Chemical and Environmental Engineering (DICCA), Genova University, 16145 Genova, Italy

Department of Clinical and Experimental Medicine, University of Foggia, 71121 Foggia, Italy

Department of Orthodontics and Dentofacial Orthopaedics, Charité Universitätsmedizin Berlin, 10117 Berlin, Germany

Department of Orthodontics, University Hospital Düsseldorf, 40225 Düsseldorf, Germany

References (19)

Show source-provided references
1. Development of biocompatible resins for 3D printing of direct aligners10.2494/photopolymer.32.209 ↗
2. Cytotoxicity and estrogenicity of a novel 3-dimensional printed orthodontic aligner10.1016/j.ajodo.2022.06.014 ↗
3. Comparison of the cytotoxicity of 3D-printed aligners using different post-curing procedures: An in vitro study10.2478/aoj-2023-0026 ↗
4. Integrated manufacturing of direct 3D-printed clear aligners10.3389/fdmed.2022.1089627 ↗
5. Termo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners10.1038/s41598-022-09831-4 ↗
6. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers10.1111/ocr.12537 ↗
7. Effect of print orientation on the dimensional accuracy of orthodontic aligners printed 3-dimensionally10.1016/j.ajodo.2021.01.018 ↗
8. Analysis of the thickness of 3-dimensional-printed orthodontic aligners10.1016/j.ajodo.2020.07.029 ↗
9. Evaluation of fit for 3D-printed retainers compared with thermoform retainers10.1016/j.ajodo.2018.09.011 ↗
10. Effect of print orientation and duration of ultraviolet curing on the dimensional accuracy of a 3-dimensionally printed orthodontic clear aligner design10.1016/j.ajodo.2020.03.023 ↗
11. Micro computed tomography evaluation of Invisalign aligner thickness homogeneity10.2319/040820-265.1 ↗
12. MicroCT X-ray comparison of aligner gap and thickness of six brands of aligners: An in-vitro study10.1186/s40510-020-00312-w ↗
13. Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures in-volving six commercial clear aligners: An in vitro study10.4041/kjod.2021.51.2.135 ↗
14. Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometer10.1038/s41598-023-36851-5 ↗
15. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
16. R Core Team (2023, August 19). R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, Vienna, Austria. Available online: http://www.R-project.org/.
17. Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution10.1117/1.JMI.9.3.031509 ↗
18. Grassia, V., Ronsivalle, V., Isola, G., Nucci, L., Leonardi, R., and Lo Giudice, A. (2023). Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition. BMC Oral Health., 23.10.1186/s12903-023-03025-8 ↗
19. Ihssen, B.A., Kerberger, R., Rauch, N., Drescher, D., and Becker, K. (2021). Impact of Dental Model Height on Thermoformed PET-G Aligner Thickness—An In Vitro Micro-CT Study. Appl. Sci., 11.10.3390/app11156674 ↗