Prototype of an Ankle Neurorehabilitation System with Heuristic BCI Using Simplified Fuzzy Reasoning
Source abstract
Abstract
Neurorehabilitation using a brain–computer interface (BCI) requires machine learning, for which calculations take a long time, even days. However, the demands of actual rehabilitation are becoming increasingly rigorous, requiring that processes be completed within tens of minutes. Therefore, we developed a new effective rehabilitation system for treating patients such as those with stroke hemiplegia. The system can smoothly perform rehabilitation training on the day of admission to the hospital. We designed a heuristic BCI with simplified fuzzy reasoning, which can detect motor intention signals from an electroencephalogram (EEG) within several tens of minutes. The detected signal is sent to the newly developed ankle rehabilitation device (ARD), and the patient repeats the dorsiflexion motion by the ARD.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: EEG and Brain-Computer Interfaces · Gaze Tracking and Assistive Technology · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Human System Interaction, School of Science and Technology, Kwansei Gakuin University, Gakuen, Sanda 669-1337, Japan
References (22)
Show source-provided references
1. (2018, February 06). Ministry of Internal Affairs and Communications statistics Bureau, population of the elderly, announced on 15 September 2016. Available online: http://www.stat.go.jp/data/jinsui/pdf/201807.pdf.
2. (2018, February 06). Ministry of Health, Labor and Welfare: Overview of the 2010 National Survey of Living in Japan. Available online: http://www.mhlw.go.jp/toukei/saikin/hw/k-tyosa/k-tyosa10/4-2.html.
3. (2018, February 13). Kintec: Kintec Breva Ankle CPM. Available online: http://kinetecuk.com/treatment-areas/foot-ankle/continuous-passive-motion/kinetec-breva.
4. Robot-aided neurorehabilitation: A pediatric robot for ankle rehabilitation10.1109/TNSRE.2015.2410773 ↗
5. Improving BCI performance through co-adaptation: Applications to the P300-speller10.1016/j.rehab.2014.10.006 ↗
6. Time-of day effects of ethanol consumption on EEG topography and cognitive event-related potential in adult males
7. McDaid, A.J., Xing, S., and Xie, S.Q. (2013, January 9–12). Brain Controlled Robotic Exoskeleton for Neurorehabilitation. Proceedings of the 2013 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, Wollongong, NSW, Australia.10.1109/AIM.2013.6584231 ↗
8. The steady-state visual evoked potential in vision research: A review10.1167/15.6.4 ↗
9. Addition of intensive repetition of facilitation exercise to mulutidisciplinary rehabilitation promotes motor functional recovery of the hemiplegic lower limb10.1080/16501970410029753 ↗
10. Improvements in limb kinetic apraxia by repetition of a newly designed facilitation exercise in a patient with corticobasal degeneration10.1097/MRR.0b013e32831e4546 ↗
11. Post-stroke Rehabilitation Training with a Motor-Imagery-Based Brain-Computer Interface (BCI)-Controlled Hand Exoskeleton: A Randomized Controlled Multicenter Trial10.3389/fnins.2017.00400 ↗
12. Fuzzy identification of systems and its applications to modeling and control10.1109/TSMC.1985.6313399 ↗
13. Face Detection from Color Images Using a Fuzzy Pattern Matching Method10.1109/34.771326 ↗
14. Eye Detection by using Fuzzy Template Matching and Feature Parameter Based Judgement10.1016/S0167-8655(01)00065-4 ↗
15. Vitroid-the robot system with an interface between a living neuronal network and outer world
16. Oda, T., and Kudoh, S.N. (2017, January 27–30). Identification of multiple-tasks-induced-EEG by heuristic BCI with learning type fuzzy-template-matching method. Proceedings of the 2017 Joint 17th World Congress of International Fuzzy Systems Association and 9th International Conference on Soft Computing and Intelligent Systems (IFSA-SCIS), Otsu, Japan.10.1109/IFSA-SCIS.2017.8023260 ↗
17. Saga, N., and Saito, N. (2008, January 1). Rehabilitation instrument for prevent contracture of ankle using the pneumatic balloon actuator. Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Saga, Japan.10.1109/IEMBS.2008.4650159 ↗
18. Ankle Rehabilitation Device to Prevent Contracture Using a Pneumatic Balloon Actuator10.20965/ijat.2011.p0538 ↗
19. (2019, April 01). Japanese Body Size Data Book. Research Institute of Human Engineering for Quality Life. Available online: https://www.hql.jp/database/cat/etc/nite_h13-14_funcdb.
20. EEGLAB: An open source toolbox for analysis of signal-trial EEG dynamics including independent component analysis10.1016/j.jneumeth.2003.10.009 ↗
21. Independent component analysis: Algorithms and applications10.1016/S0893-6080(00)00026-5 ↗
22. An information-maximization approach to blind separation and blind deconvolution10.1162/neco.1995.7.6.1129 ↗