Development and Application of MAGIC-f Gel in Cancer Research and Medical Imaging
Source abstract
Abstract
Much of the complex medical physics work requires radiation dose delivery, which requires dosimeters to accurately measure complex three-dimensional dose distribution with good spatial resolution. MAGIC-f polymer gel is one of the emerging new dosimeters widely used in medical physics research. The purpose of this study was to present an overview of polymer gel dosimetry, using MAGIC-f gel, including its composition, manufacture, imaging, calibration, and application to medical physics research. In this review, the history of polymer gel development is presented, along with the applications so far. Moreover, the most important experiments/applications of MAGIC-f polymer gel are discussed to illustrate the behavior of gel on different conditions of irradiation, imaging, and manufacturing techniques. Finally, various future works are suggested based on the past and present works on MAGIC-f gel and polymer gel in general, with the hope that these bits of knowledge can provide important clues for future research on MAGIC-f gel as a dosimeter.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · Medical Imaging Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA
References (92)
Show source-provided references
1. Baldock, C. (2006). Historical Overview of the Development of Gel Dosimetry: A Personal Perspective, IOP Publishing.10.1088/1742-6596/56/1/002 ↗
2. Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications10.4329/wjr.v9.i3.112 ↗
3. Polymer gel dosimetry10.1088/0031-9155/55/5/R01 ↗
4. Evaluation of the response of modified MAGIC-f polymeric gel using a clinical brachytherapy source and Monte Carlo simulation with package PENELOPE10.29384/rbfm.2016.v10.n3.p2-6 ↗
5. Dose resolution optimization of polymer gel dosimeters using different monomers10.1088/0031-9155/46/10/310 ↗
6. Superparamagnetic iron oxide nanoparticles conjugated with epidermal growth factor (SPION–EGF) for targeting brain tumors10.2147/IJN.S55118 ↗
7. Role of anti-oxidants on normoxic methacrylic acid gelatin (MAG) polymer gel dosimeter at 6-MV photon beam using single spin echo MRI
8. Chemical effects of ionizing radiation in some gels10.1038/166146a0 ↗
9. The degradation of solid polymethylmethacrylate by ionizing radiation
10. Radiation polymerization dosimetry10.1016/0020-708X(58)90053-X ↗
11. A polyacrylamide gamma dosimeter10.2307/3570986 ↗
12. Audet, C., and Schreiner, L. (1991, January 10–16). Radiation dosimetry by NMR relaxation time measurements of irradiated polymer solutions. Proceedings of the International Society for Magnetic Resonance in Medicine, San Francisco, CA, USA.
13. Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging10.1088/0031-9155/29/10/002 ↗
14. The chemical action of roentgen rays on dilute ferrosulphate solutions as a measure of dose
15. Schreiner, L. (2004). Review of Fricke gel Dosimeters, IOP Publishing.10.1088/1742-6596/3/1/003 ↗
16. Hydrodynamic effects and cross relaxation in cross linked polymer gels
17. Spevacek, J., Dvorak, P., Cechak, T., Novotny, J., and Marek, M. (2001). The use of gel dosimetry of Fricke type in three-dimensional dosimetry, DRO.
18. Imaging of spatial radiation dose distribution in agarose gels using magnetic resonance10.1118/1.596052 ↗
19. Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonance10.1088/0031-9155/35/12/002 ↗
20. Diffusion of ferric ions in agarose dosimeter gels10.1088/0031-9155/37/12/006 ↗
21. Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method10.1007/BF03178282 ↗
22. Fast T1 imaging of dual gel samples for diffusion measurements in NMR dosimetry gels10.1016/S0730-725X(96)00352-9 ↗
23. Maryanski, M., Gore, J., and Schulz, R. (1992). 3-D radiation dosimetry by MRI: Solvent proton relaxation enhancement by radiation-controlled polymerisation and cross-linking in gels. Proc. Int. Soc. Magn. Reson. Med. (New York).
24. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter10.1088/0031-9155/39/9/010 ↗
25. Maryanski, M., Gore, J., and Schulz, R. (1994). Three-Dimensional Detection, Dosimetry and Imaging of an Energy Field by Formation of a Polymer in a Gel. (5,321,357), U.S. Patent.
26. Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry10.1088/0031-9155/43/3/019 ↗
27. A new polymer gel for magnetic resonance imaging (MRI) radiation dosimetry10.1088/0031-9155/44/10/320 ↗
28. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere10.1088/0031-9155/46/12/303 ↗
29. Dose–response stability and integrity of the dose distribution of various polymer gel dosimeters10.1088/0031-9155/47/14/307 ↗
30. Polymer gel dosimeters with reduced toxicity: A preliminary investigation of the NMR and optical dose–response using different monomers10.1088/0031-9155/51/14/001 ↗
31. A basic study of some normoxic polymer gel dosimeters10.1088/0031-9155/47/19/301 ↗
32. Fernandes, J.P., Pastorello, B.F., de Araújo, D.B., and Baffa, O. (2009). Formaldehyde Increases MAGIC Gel Dosimeter Melting Point and Sensitivity, IOP Publishing.10.1088/1742-6596/164/1/012004 ↗
33. MAGIC-type polymer gel for three-dimensional dosimetry: Intensity-modulated radiation therapy verification10.1118/1.1576392 ↗
34. Marques, T., Schwarcke, M., Garrido, C., Baffa, O., and Nicolucci, P. (2010). Dosimetric Properties of MAGIC-f Polymer Gel Assessed to Radiotherapy Clinical Beams, IOP Publishing.10.1088/1742-6596/250/1/012012 ↗
35. An evaluation of dosimetric characteristics of MAGIC gel modified by adding formaldehyde (MAGIC-f)10.1016/j.radmeas.2012.10.004 ↗
36. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry10.1118/1.4704496 ↗
37. Use of BANG® polymer gel for dose measurements in a 68 MeV proton beam10.1118/1.1575557 ↗
38. Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements10.1088/0031-9155/49/17/002 ↗
39. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy10.1118/1.3388869 ↗
40. Relative effectiveness of polyacrylamide gel dosimeters applied to proton beams: Fourier transform Raman observations and track structure calculations10.1118/1.1460873 ↗
41. Direct response to proton beam linear energy transfer (LET) in a novel polymer gel dosimeter formulation10.7785/tcrt.2012.500263 ↗
42. Development and optimization of a 2-hydroxyethylacrylate MRI polymer gel dosimeter10.1088/0031-9155/49/2/004 ↗
43. Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements10.1088/0031-9155/44/8/310 ↗
44. Pianoschi, T., Alva, M., Santanna, M., Baffa, O., and Nicolucci, P. (2010). MAGIC-f Gel Dosimetry for Clinical Electron Beam, IOP Publishing.10.1088/1742-6596/250/1/012037 ↗
45. High resolution gel-dosimetry by optical-CT and MR scanning10.1118/1.1380430 ↗
46. Polymer gel dosimetry using x-ray computed tomography: A feasibility study410.1088/0031-9155/45/9/309 ↗
47. Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer10.1016/S0167-8140(98)00087-5 ↗
48. NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI10.1016/0730-725X(93)90030-H ↗
49. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters10.1088/0031-9155/47/24/307 ↗
50. Ultrasound evaluation of polymer gel dosimeters10.1088/0031-9155/47/9/302 ↗
51. Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry10.1088/0031-9155/43/12/017 ↗
52. An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography10.1088/0031-9155/46/11/312 ↗
53. Determine the dose distribution using ultrasound parameters in MAGIC-f polymer gels10.1177/1559325815625647 ↗
54. A variable echo-number method for estimating in MRI-based polymer gel dosimetry10.1118/1.3544659 ↗
55. Ibbott, G.S. (2004). Applications of Gel Dosimetry, IOP Publishing.10.1088/1742-6596/3/1/007 ↗
56. Radiation dosimetry using polymer gels: Methods and applications10.1259/bjr.73.873.11064643 ↗
57. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry10.1088/0031-9155/47/20/201 ↗
58. Gel dosimeter for depth-dose measurements10.1063/1.1715877 ↗
59. Dose response characteristics and basic dose distribution data for a polymerization-based dosemeter gel evaluated using MR10.1259/bjr.73.865.10721321 ↗
60. An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry10.1088/0031-9155/43/5/005 ↗
61. A dosimetry phantom for external beam radiation therapy of the breast using radiation-sensitive polymer gels and MRI
62. Polymer gel measurement of dose homogeneity in the breast: Comparing MLC intensity modulation with standard wedged delivery10.1088/0031-9155/48/8/308 ↗
63. The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp10.1088/0031-9155/49/9/003 ↗
64. The dose response of normoxic polymer gel dosimeters measured using X-ray CT10.1259/bjr/46029447 ↗
65. Webb, S. (1997). The Physics of Conformal Radiotherapy: Advances in Technology (PBK), CRC Press.10.1201/9781420050806 ↗
66. Imaging of HDR brachytherapy dose distributions using NMR Fricke-gelatin dosimetry10.1016/0730-725X(94)92031-1 ↗
67. Absorbed dose distribution measurements in brachytherapy using ferrous sulphate gel and magnetic resonance imaging10.1259/0007-1285-67-803-1121 ↗
68. Polymerization kinetics of polyacrylamide gels II. Effect of temperature10.1002/elps.1150020405 ↗
69. Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter10.1088/0031-9155/42/2/004 ↗
70. Modified acrylic-based superabsorbent polymers. Effect of temperature and initiator concentration10.1016/S0032-3861(97)10236-1 ↗
71. Three-dimensional determination of absorbed dose by spectrophotometric analysis of ferrous-sulphate agarose gel10.1016/S0168-9002(98)00975-9 ↗
72. Gambarini, G. (2001, January 18–21). Gel Dosimetry in Neutron Capture Therapy. Proceedings of the DOSGEL 2001, 2nd International Conference on Radiotherapy Gel Dosimetry, Brisbane, Australia.
73. Fricke gel dosimetry in boron neutron capture therapy10.1093/oxfordjournals.rpd.a006015 ↗
74. Investigating the potential of polymer gel dosimetry for interventional radiology: First results10.1088/0031-9155/53/8/N02 ↗
75. Maryanski, M., Schulz, R., and Gore, G. (, 1994). Three dimensional dose distributions for 160 MeV protons using MRI of the tissue-equivalent BANG polymer-gel dosimeter. Proceedings of the PTCOG Newsletter, MA, USA.
76. Schubert, J. (1973). Radiation Chemistry—An Introduction: AJ Swallow, Longman Group, Ltd.
77. Three-dimensional BANG™gel dosimetry in conformal carbon10.1088/0031-9155/45/9/401 ↗
78. Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy10.1088/0031-9155/49/15/013 ↗
79. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions10.1016/S0167-8140(02)00376-6 ↗
80. Preliminary study on the use of an inhomogeneous anthropomorphic Fricke gel phantom and 3D magnetic resonance dosimetry for verification of IMRT treatment plans10.1088/0031-9155/47/7/401 ↗
81. Dose distribution measurements by MRI of a phantom containing lung tissue equivalent compartments made of ferrous sulphate gel10.1088/0031-9155/45/10/303 ↗
82. Borges, J., BenComo, J., and Ibbott, G. (2003, January 10–14). A 3 Dimensional Gel Dosimetry Lung Equivalent (WIP). Proceedings of the AAPM Annual Meeting, San Diego, CA, USA.
83. Schwarcke, M., Marques, T., Garrido, C., Nicolucci, P., and Baffa, O. (2010). MAGIC-f Gel in Nuclear Medicine Dosimetry: Study in an External Beam of Iodine-131, IOP Publishing.10.1088/1742-6596/250/1/012082 ↗
84. Tridimensional dosimetry for prostate IMRT treatments using MAGIC-f gel by MRI10.1016/j.radmeas.2014.07.011 ↗
85. Polymer gel dosimetry by nuclear Overhauser enhancement (NOE) magnetic resonance imaging10.1088/1361-6560/aad1bd ↗
86. SU-GG-I-90: Dose Distribution of Small Fields through MAGIC-F Gel Dosimetry and PENELOPE-Monte Carlo Simulation10.1118/1.3468123 ↗
87. Monte Carlo Simulation of MAGIC-f gel for Radiotherapy using PENELOPE
88. Use of gold nanoparticles in MAGIC-f gels to 18 MeV photon enhancement
89. Image distortion in MRI-based polymer gel dosimetry of gamma knife stereotactic radiosurgery systems10.1118/1.1470204 ↗
90. Technical considerations for implementation of x-ray CT polymer gel dosimetry10.1088/0031-9155/50/8/008 ↗
91. Radiological properties of the PRESAGE and PAGAT polymer dosimeters10.1016/j.apradiso.2008.06.005 ↗
92. Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI10.1088/0031-9155/51/4/011 ↗