Semi-Active Cable Damping to Compensate for Damping Losses Due to Reduced Cable Motion Close to Cable Anchor
Source abstract
Abstract
The relative motion of transverse cable dampers is smaller than predicted by the taut string model because of the effects of bending stiffness and fixed support conditions. As a result of the reduced damper motion, the dissipated energy per cycle is reduced as well, which may explain why damping measurements on real stay cables with transverse dampers often show lower cable damping ratios than expected from the taut string theory. To compensate for the reduced damper motion and damper efficiency, respectively, a semi-active cable damper is proposed. The controllable damper is realized by a hydraulic oil damper with real-time controlled bypass valve whereby the resulting damper force is purely dissipative. The proposed control law is clipped viscous damping with negative stiffness. The viscous coefficient is adjusted in real time to the actual frequency of vibration to generate optimum modal damping while the negative stiffness component partially compensates for the reduced damper motion due to the flexural rigidity and fixed support conditions of the cable. The measurements of the prototype semi-active hydraulic damper are used to derive a precise model of the semi-active damper force including the control force constraints due to the fully open and fully closed bypass valve. This model is used to compute the cable damping ratios of the first four cable modes, for typical damper positions, for a taut string model and for a cable model with flexural rigidity and fixed supported ends. The obtained cable damping ratios are compared to those resulting from the passive linear viscous damper being optimized to the first four cable modes. The results demonstrate that the proposed semi-active cable damper with the consideration of the minimum and maximum control force constraints significantly enhances the cable damping of the first four modes compared to the linear viscous damper.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vibration Control and Rheological Fluids · Structural Engineering and Vibration Analysis · Vibration and Dynamic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Maurer Switzerland GmbH, Grossplatzstrasse 24, 8118 Pfaffhausen, Switzerland
Maurer SE, Frankfurter Ring 193, 80807 Munich, Germany
Maurer Engineering GmbH, Frankfurter Ring 193, 80807 Munich, Germany
References (47)
Show source-provided references
1. Fib Bulletin 30 (2005). Acceptance of stay cable systems using prestressing steels. Bulletin 30, International Federation for Structural Concrete Fib.
2. Jain, A., Simsir, C., and Sarkar, P.P. (2018). Analysis, Measurement, and Mitigation of Stay Cable Vibrations. Eighth Congr. Forensic Eng., 791–799.10.1061/9780784482018.076 ↗
3. Response characteristics of rain-wind induced vibration of stay-cables of cable-stayed bridges10.1016/0167-6105(95)00010-O ↗
4. Interpretation of field observations of wind- and rain-wind-induced stay cable vibrations10.1016/j.jweia.2009.09.004 ↗
5. Rain-wind-induced in-plane and out-of-plane vibrations of stay cables10.1061/(ASCE)EM.1943-7889.0000612 ↗
6. Long-term monitoring of wind characteristics at Sutong Bridge site10.1016/j.jweia.2013.01.006 ↗
7. Guo, J., and Zhu, X. (2020). Field Monitoring and Analysis of the Vibration of Stay Cables under Typhoon Conditions. Sensors, 20.10.3390/s20164520 ↗
8. Vibration Control Techniques for Dynamic Response Mitigation of Civil Structures under Multiple Hazards
9. Observations of bridge stay cable vibrations in dry and wet conditions: A case study10.1016/j.jsv.2021.116106 ↗
10. Galloping vibration of stay cable installed with a rectangular lamp: Field observations and wind tunnel tests10.1016/j.jweia.2021.104685 ↗
11. Field observations of rain-wind-induced cable vibration in cable-stayed Dongting Lake Bridge10.1016/j.jweia.2006.07.001 ↗
12. Cable vibrations at Dubrovnik bridge10.1080/15732480600855800 ↗
13. Rain-wind-induced cable vibrations in the Alamillo cable-stayed bridge (Sevilla, Spain). Assessment and remedial action10.1080/15732470903068607 ↗
14. Estimation curve for modal damping in stay cables with viscous damper10.1061/(ASCE)0733-9445(1993)119:6(1961) ↗
15. Vibrations of a taut cable with an external damper10.1115/1.1322037 ↗
16. Free vibrations of taut cable with attached damper. I: Linear viscous damper10.1061/(ASCE)0733-9399(2002)128:10(1062) ↗
17. Damping of cables by a transverse force10.1061/(ASCE)0733-9399(2005)131:4(340) ↗
18. Vibration Mechanisms and Controls of Long-Span Bridges: A Review10.2749/101686613X13439149156886 ↗
19. Design of viscous dampers targeting multiple cable modes10.1016/j.engstruct.2009.06.020 ↗
20. Analytical study on bending effects in a stay cable with a damper10.1061/(ASCE)0733-9399(2007)133:11(1241) ↗
21. Free Vibration Analysis of Cable Stayed-Bridge by Finite Element Method10.24237/djes.2019.12407 ↗
22. Damping of Stay Cable-Passive Damper System with Effects of Cable Bending Stiffness and Damper Stiffness
23. Optimal semi-active damping of cables with bending stiffness10.1088/0964-1726/20/5/055005 ↗
24. Clipped viscous damping with negative stiffness for semi-active cable damping10.1088/0964-1726/20/4/045007 ↗
25. State-derivative feedback control of cable vibration using semiactive magnetorheological dampers10.1111/j.1467-8667.2005.00396.x ↗
26. Experimental verification of smart cable damping10.1061/(ASCE)0733-9399(2006)132:3(268) ↗
27. Cable vibration control using magnetorheological dampers10.1177/1045389X06054997 ↗
28. Damping of Full-Scale Stay Cable with Viscous Damper: Experiment and Analysis10.1260/1369-4332.17.2.265 ↗
29. Amplitude and frequency independent cable damping of Sutong Bridge and Russky Bridge by MR dampers10.1002/stc.1671 ↗
30. Damping estimation from free decay responses of cables with MR dampers
31. Full-scale test of dampers for stay cable vibration mitigation and improvement measures
32. Development of a cable exciter to evaluate damping ratios of a stay cable10.1007/s12205-010-0363-6 ↗
33. Bournand, Y., and Crigler, J. (2005, January 19–22). The VSL friction damper for cable-stayed bridges. Some results from maintenance and testing on long cables. Proceedings of the 6th International Conference on Cable Dynamics 2005, Charleston, SC, USA.
34. Optimal tuning of amplitude proportional Coulomb friction damper for maximum cable damping10.1061/(ASCE)0733-9445(2010)136:2(123) ↗
35. Energy Based Optimization of Viscous-Friction Dampers on Cables10.1088/0964-1726/19/4/045025 ↗
36. Experimental study of vibration control of a cable with an attached MR damper
37. Negative stiffness characteristics of active and semi-active control systems for stay cables10.1002/stc.200 ↗
38. Bouc-Wen model-based real-time force tracking scheme for MR dampers10.1088/0964-1726/22/4/045012 ↗
39. Robust force tracking control scheme for MR dampers10.1002/stc.1750 ↗
40. Modeling and control performance of a negative stiffness damper for suppressing stay cable vibrations10.1002/stc.1809 ↗
41. Vibration control of a stay cable with a rotary electromagnetic inertial mass damper
42. Vibration mitigation of stay cables using electromagnetic inertial mass dampers: Full-scale experiment and analysis10.1016/j.engstruct.2019.109693 ↗
43. Cable vibration control with internal and external dampers: Theoretical analysis and field test validation
44. Serviceability Assessment Method of Stay Cables with Vibration Control Using First-Passage Probability10.1155/2019/4138279 ↗
45. Bathe, K.-J. (1982). Finite Element Procedures in Engineering Analysis, Prentice-Hall.
46. Semi-active damping with negative stiffness for multi-mode cable vibration mitigation: Approximate collocated control solution10.1088/0964-1726/24/11/115015 ↗
47. Precise Stiffness and Damping Emulation with MR Dampers and its Application to Semi-active Tuned Mass Dampers of Wolgograd Bridge10.1088/0964-1726/23/1/015019 ↗