In the process of power transformer risk assessment, the loss degree index is difficult to accurately quantify due to the influence of uncertain factors, leading to the deviation of risk judgment. A power transformer risk assessment method based on the three-parameter interval grey number decision-making is proposed. Firstly, the fault probability of the transformer is quantified based on the condition evaluation results. Secondly, considering the uncertainty of DG output and load, the Nataf transform and Cholesky decomposition were used to eliminate the correlation of random variables, and a three-point estimation method combined with a DC cut load model was introduced to calculate the probability distribution of the loss degree caused by the transformer fault. Finally, the origin moment of each order was obtained based on the calculation formula of risk value, and the risk probability distribution was obtained through the Cornish–Fisher series expanding. The decision method of the three-parameter interval grey number distance measure was used to judge the risk grade of the equipment. The results show that the proposed method fully considers the influence of uncertainty on equipment risk judgment, can realize the full use of the equipment risk value interval number to judge the risk, and avoids the decision-making defects of the traditional certain risk quantification method. Meanwhile, the influence of different factors on the risk evaluation results is in line with the actual operation condition of the transformer. The results also verify the effectiveness and accuracy of the proposed method, which provides a new judgment idea for power grid equipment risk quantitative assessment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Transformer Diagnostics and Insulation · Material Properties and Failure Mechanisms · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Electrical Engineering, Guizhou University, Guiyang 550025, China
Guizhou Power Grid Co., Ltd., Guiyang 550002, China
Funding
National Natural Science Foundation under Grant · Guizhou science and technology fund projects under Grant
References (30)
Show source-provided references
1. Impact of grid connection of large-scale wind farms on power system small-signal angular stability10.17775/CSEEJPES.2015.00023 ↗
2. Analysis and recommendations for the adaptability of China’s power system security and stability relevant standards10.17775/CSEEJPES.2017.00650 ↗
3. Review on asset management of power transformer by diagnosing incipient faults and faults identification using various testing methodologies10.1016/j.engfailanal.2021.105634 ↗
4. Understanding the power transformer component failures for health index-based maintenance planning in electric utilities10.1016/j.engfailanal.2018.10.011 ↗
5. A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers10.1007/s00202-017-0532-4 ↗
6. Chen, J.M., Bi, T.S., and Sun, M. (2016, January 10–13). Study on quality risk assessment for power transformer based on fault tree analysis. Proceedings of the 2016 China International Conference on Electricity Distribution (CICED), Xi’an, China.10.1109/CICED.2016.7576091 ↗
7. Chen, J., Li, Y., Zhao, H., Wu, L., Wei, F., and Qin, X. (October, January 28). Study on risk assessment for power transformer. Proceedings of the 2016 IEEE International Conference on Power System Technology (POWERCON), Wollongong, Australia.10.1109/POWERCON.2016.7753859 ↗
8. Lin, D., Xu, Y.Y., Liang, Y., Li, Y., Liu, N., and Zhang, G.J. (2017, January 14–17). A risk assessment method of transformer considering the economy and reliability of power network. Proceedings of the 2017 1st International Conference on Electrical Materials and Power Equipment (ICEMPE), Xi’an, China.10.1109/ICEMPE.2017.7982167 ↗
9. He, D., Zhang, Y., Guo, C., Zhang, J., Liu, H., and Duan, Y. (2016, January 17–21). Failure probability model of transmission and transformation equipment for risk assessment. Proceedings of the 2016 IEEE Power and Energy Society General Meeting (PESGM), Boston, MA, USA.
10. A Practical method for risk assessment in power transformer fleets10.15446/dyna.v84n200.54364 ↗
11. Chen, Q., Xiong, X., Xiao, C., He, L., Pu, Y., and Chen, H. (2019, January 21–23). The Probabilistic Assessment of Outgoing Transformer Operation Risk Considering the Correlation Between Wind Power and Photovoltaic. Proceedings of the 2019 IEEE Sustainable Power and Energy Conference (iSPEC), Beijing, China.10.1109/iSPEC48194.2019.8975137 ↗
12. Risk Assessment Based on Condition and Importance Criteria for Power Transformer in Thailand Transmission Network10.1002/tee.22061 ↗
13. Taengko, K., and Damrongkulkamjorn, P. (2013, January 15–17). Risk assessment for power transformers in PEA substations using health index. Proceedings of the 2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, Krabi, Thailand.10.1109/ECTICon.2013.6559602 ↗
14. Liu, H., Wang, Z., and Wang, X. (2017, January 15–17). Transformer risk assessment model under condition based maintenance. Proceedings of the 2017 IEEE 2nd Information Technology, Networking, Electronic and Automation Control Conference (ITNEC), Chengdu, China.
15. Wang, Y., Zhao, X., Bian, J., Liao, R., and Yang, L. (2012, January 17–20). Cloud model-based risk assessment of power transformer. Proceedings of the 2012 International Conference on High Voltage Engineering and Application, Shanghai, China.
16. Risk assessment of power transformer potential fault based on cloud theory and entropy weight methods
17. Risk Assessment and Working-out of Maintenance Strategy for Power Transformer Based on Cloud Model
18. Comprehensive Condition Assessment of Power Transformer Based on Asymmetric Nearness Degree Evidence Cloud Matter-element Model
19. A novel extension method for transformer fault diagnosis10.1109/TPWRD.2002.803838 ↗
20. Transformer Fault Condition Prognosis Using Vibration Signals Over Cloud Environment10.1109/ACCESS.2018.2809436 ↗
21. Yu, H., Yu, Y., Wang, M., Xiong, W., Yuan, X., and Zou, X. (2021, January 28–30). A Power Transformer Condition Assessment Method Based on Fuzzy Nearness Degree and Improved Cloud Matter-element Model. Proceedings of the 2021 IEEE 4th International Electrical and Energy Conference (CIEEC), Wuhan, China.10.1109/CIEEC50170.2021.9510875 ↗
22. Dong, J., Wang, D., Liu, D., Ainiwaer, P., and Nie, L. (2019). Operation health assessment of power market based on improved matter-element extension cloud model. Sustainability, 11.10.3390/su11195470 ↗
23. A Novel Maintenance Decision Making Model of Power Transformers Based on Reliability and Economy Assessment10.1109/ACCESS.2019.2897606 ↗
24. Yang, H., Zhe, Z., Yin, X., Han, J., Yong, W., and Chen, G. (2017). A Novel Short-Term Maintenance Strategy for Power Transmission and Transformation Equipment Based on Risk-Cost-Analysis. Energies, 10.10.3390/en10111865 ↗
25. Probabilistic Transient Stability Constrained Optimal Power Flow for Power Systems With Multiple Correlated Uncertain Wind Generations10.1109/TSTE.2016.2520481 ↗
26. An Efficient Probabilistic Approach Based on Area Grey Incidence Decision Making for Optimal Distributed Generation Planning10.1109/ACCESS.2019.2927713 ↗
27. Multivariate distribution models with prescribed marginals and covariances10.1016/0266-8920(86)90033-0 ↗
28. Probabilistic Power Flow Studies for Transmission Systems With Photovoltaic Generation Using Cumulants10.1109/TPWRS.2012.2190533 ↗
29. Luo, D., Mao, W., and Sun, H. (2016, January 9–12). Grey dominance-based rough set approach to decision system with three-parameter interval grey number. Proceedings of the 2016 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Budapest, Hungary.
30. Li, Y., Niu, Y., Wang, W., and Li, B. (2017, January 8–11). Grey-incidence clustering decision-making method with three-parameter interval grey number based on regret theory. Proceedings of the 2017 International Conference on Grey Systems and Intelligent Services (GSIS), Stockholm, Sweden.10.1109/GSIS.2017.8077706 ↗