journal article·2022-10-10Open access

Comparison of Phase-Screen and Geometry-Based Phase Aberration Correction Techniques for Real-Time Transcranial Ultrasound Imaging

Moein Mozaffarzadeh, Martin D. Verweij, Nico de Jong, Guillaume Renaud

Applied Sciences· Volume 12· Issue 19

Abstract

While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based phase aberration correction technique (GB) when an ultrafast imaging sequence (five plane waves tilted from −15 to +15 degrees in the cutaneous tissue layer) is used for data acquisition. With simulation data, the aberration profile (AP) of two aberrator models (flat and realistic temporal bone) was estimated in five isoplanatic patches, while the wave-speed of the brain tissue surrounding the point targets was either modeled homogeneously (ideal) or slightly heterogeneously to generate speckle (for mimicking a more realistic brain tissue). For the experiment, a phased array P4-1 transducer was used to image a wire phantom; a 4.2-mm-thick bone-mimicking plate was placed in front of the probe. The AP of the plate was estimated in three isoplanatic patches. The numerical results indicate that, while all the scatterers are detectable in the image reconstructed by the GB method, many scatterers are not detected with the PS method when the dataset used for AP estimation is generated with a realistic bone model and heterogeneous brain tissue. The experimental results show that the GB method increases the signal-to-clutter ratio (SCR) by 7.5 dB and 6.5 dB compared to the PS and conventional reconstruction methods, respectively. The GB method reduces the axial/lateral localization error by 1.97/0.66 mm and 2.08/0.7 mm compared to the PS method and conventional reconstruction, respectively. The lateral spatial resolution (full-width-half-maximum) is also improved by 0.1 mm and 1.06 mm compared to the PS method and conventional reconstruction, respectively. Our comparison study suggests that GB aberration correction outperforms the PS method when an ultrafast multi-angle plane wave sequence is used for transcranial imaging with a single transducer.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Ultrasound Imaging and Elastography · Ultrasonics and Acoustic Wave Propagation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands

Department Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands

Funding

Netherlands Organisation for Scientific Research (NWO)

References (44)

Show source-provided references
1. Transcranial Ultrasound from Diagnosis to Early Stroke Treatment10.1159/000166844 ↗
2. Transcranial Ultrasound from Diagnosis to Early Stroke Treatment—Part 2: Prehospital Neurosonography in Patients with Acute Stroke—The Regensburg Stroke Mobile Project10.1159/000334667 ↗
3. Prehospital use of portable ultrasound for stroke diagnosis and treatment initiation
4. Antipova, D., Eadie, L., Makin, S., Shannon, H., Wilson, P., and Macaden, A. (2020). The use of transcranial ultrasound and clinical assessment to diagnose ischaemic stroke due to large vessel occlusion in remote and rural areas. PLoS ONE, 15.10.1371/journal.pone.0239653 ↗
5. Prehospital stroke diagnostics based on neurological examination and transcranial ultrasound10.1186/2036-7902-6-3 ↗
6. Applications of transcranial Doppler in the ICU: A review10.1007/s00134-006-0173-y ↗
7. TCD in sickle cell disease: An important and useful test10.1007/s00247-005-1409-7 ↗
8. Optimizing Primary Stroke Prevention in Sickle Cell Anemia (STOP 2) Trial Investigators (2005). Investigators. Discontinuing prophylactic transfusions used to prevent stroke in sickle cell disease. N. Engl. J. Med., 353, 2769–2778.10.1056/NEJMoa050460 ↗
9. Prevention of a First Stroke by Transfusions in Children with Sickle Cell Anemia and Abnormal Results on Transcranial Doppler Ultrasonography10.1056/NEJM199807023390102 ↗
10. Transcranial Doppler correlation with cerebral angiography in sickle cell disease10.1161/01.STR.23.8.1073 ↗
11. Distribution of Angiographic Vasospasm after Subarachnoid Hemorrhage: Implications for Diagnosis by Transcranial Doppler Ultrasonography10.1227/00006123-199010000-00011 ↗
12. Role of transcranial Doppler monitoring in the diagnosis of cerebral vasospasm after subarachnoid hemorrhage
13. Acoustical properties of the human skull10.1121/1.381852 ↗
14. Adaptive focusing for transcranial ultrasound imaging using dual arrays10.1121/1.2354073 ↗
15. Attenuation, scattering, and absorption of ultrasound in the skull bone10.1118/1.3668316 ↗
16. Association between Tomographic Characteristics of the Temporal Bone and Transtemporal Window Quality on Transcranial Color Doppler Ultrasound in Patients with Stroke or Transient Ischemic Attack10.1016/j.ultrasmedbio.2020.10.023 ↗
17. Physical and technical aspects of ultrasonic brain imaging through thick skull bones: 2. Experimental studies10.1134/1.1591292 ↗
18. Physical and technological aspects of ultrasonic imaging of brain structures through thick skull bones: 1. Theoretical and model studies10.1134/1.1574354 ↗
19. Spatial and temporal aberrator stability for real-time adaptive imaging10.1109/TUFFC.2005.1516023 ↗
20. Vignon, F., Aubry, J.-F., Tanter, M., Margoum, A., Fink, M., and Lecoeur, J. (2016, January 18–21). Dual-arrays brain imaging prototype: Experimental in vitro results. Proceedings of the IEEE International Ultrasonics Symposium, Tours, France.
21. Phase-aberration correction with a 3-D ultrasound scanner: Feasibility study10.1109/TUFFC.2006.1665100 ↗
22. Real-Time 3-D Contrast-Enhanced Transcranial Ultrasound and Aberration Correction10.1016/j.ultrasmedbio.2008.01.015 ↗
23. Comparison of 3-D multi-lag cross-correlation and speckle brightness aberration correction algorithms on static and moving targets10.1109/TUFFC.2009.1298 ↗
24. Transcranial ultrasound imaging with speed of sound-based phase correction: A numerical study10.1088/0031-9155/58/19/6663 ↗
25. Variable speed of sound compensation in the linear-array photoacoustic tomography using a multi-stencils fast marching method10.1016/j.bspc.2018.04.012 ↗
26. An Ultrasonic-Adaptive Beamforming Method and Its Application for Trans-skull Imaging of Certain Types of Head Injuries; Part I: Transmission Mode10.1109/TBME.2014.2371752 ↗
27. Ray Theory-Based Transcranial Phase Correction for Intracranial Imaging: A Phantom Study10.1109/ACCESS.2019.2951152 ↗
28. Time-reversal transcranial ultrasound beam focusing using a k-space method10.1088/0031-9155/57/4/901 ↗
29. Experimental validation of a finite-difference model for the prediction of transcranial ultrasound fields based on CT images10.1088/0031-9155/57/23/8005 ↗
30. Full-Matrix Phase Shift Migration Method for Transcranial Ultrasonic Imaging10.1109/TUFFC.2020.3016382 ↗
31. Refraction-Corrected Transcranial Ultrasound Imaging Through the Human Temporal Window Using a Single Probe10.1109/TUFFC.2022.3148121 ↗
32. In vivo ultrasound imaging of the bone cortex10.1088/1361-6560/aac784 ↗
33. Measuring anisotropy of elastic wave velocity with ultrasound imaging and an autofocus method: Application to cortical bone10.1088/1361-6560/abb92c ↗
34. Accelerated 2D Real-Time Refraction-Corrected Transcranial Ultrasound Imaging10.1109/TUFFC.2022.3189600 ↗
35. Medical Image Segmentation Based on Accelerated Dijkstra Algorithm10.1007/978-3-642-27869-3_45 ↗
36. Ultrasound for the brain: A review of physical and engineering principles, and clinical applications10.1109/TUFFC.2020.3019932 ↗
37. Transcranial ultrafast ultrasound localization microscopy of brain vasculature in patients10.1038/s41551-021-00697-x ↗
38. Time Reversal of Speckle Noise10.1103/PhysRevLett.106.054301 ↗
39. Phase-aberration correction using signals from point reflectors and diffuse scatterers: Basic principles10.1109/58.9333 ↗
40. Rigby, K.W., Chalek, C.L., Haider, B.H., Lewandowski, R.S., O’Donnell, M., Smith, L.S., and Wildes, D.G. (2000, January 22–25). Improved in vivo abdominal image quality using real-time estimation and correction of wavefront arrival time errors. Proceedings of the 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No. 00CH37121), San Juan, PR, USA.
41. k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields10.1117/1.3360308 ↗
42. Effect of Skull Porous Trabecular Structure on Transcranial Ultrasound Imaging in the Presence of Elastic Wave Mode Conversion at Varying Incidence Angle10.1016/j.ultrasmedbio.2021.05.010 ↗
43. Modeling Ultrasound Propagation in the Moving Brain: Applications to Shear Shock Waves and Traumatic Brain Injury10.1109/TUFFC.2020.3022567 ↗
44. Photoacoustic imaging through a cortical bone replica with anisotropic elasticity10.1063/5.0011260 ↗