The Duration Effect of Pulse-Type Near-Field Earthquakes on Nonlinear Dynamic Analysis and Damage Evaluation of Hydraulic Tunnels
Source abstract
Abstract
Current research trends in significant hydraulic engineering projects focus on investigating the seismological properties of intensity and frequency content of pulse-type near-field earthquakes on the structural response. Conversely, the duration impact is not expressly addressed in the seismic design code for underground buildings. Currently, various duration indicators of as-recorded strong ground motions mainly consider the effective duration of the initial acceleration component record. In contrast, the duration indicators for the effective velocity duration (EVD) of the original velocity time-history component record have rarely been addressed. Specifically, there is a gap between the effective velocity duration and the structural response. To illustrate the impact on the structural response, an EVD of pulse-type NFGM duration was used. This EVD can be calculated for seismic excitations with set threshold values that enable a quantitative examination of the duration effects. A fluid-hydraulic tunnel-rock interaction system was built and used to estimate the seismic response characteristics induced by different duration NFGMs. The investigation’s findings highlight that the inelastic dynamic response and damage degree are strongly affected by the EVD. Additionally, the fixed threshold value of 5–95% showed an excellent correlation coefficient with the structural response. The significant duration was also found to be the most suitable alternative indicator to replace the EVD index. In addition, the reduced time-history methodology of near-fault earthquake records is presented and validated, with this method being used to improve the efficiency of the dynamic time-history analysis of hydraulic arched tunnels.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Underground Structures · Seismic Waves and Analysis · Dam Engineering and Safety
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Water Conservancy Engineering, Zhengzhou University, Zhengzhou 450001, China
State Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin 300350, China
Key Laboratory of Earthquake Engineering Simulation and Seismic Resilience of China Earthquake Administration, Tianjin 300350, China
Funding
National Natural Science Foundation of China
References (43)
Show source-provided references
1. Nonlinear dynamic analysis and damage evaluation of hydraulic arched tunnels under mainshock–aftershock ground motion sequences10.1016/j.tust.2020.103321 ↗
2. Seismic damage assessment and mechanism analysis of underground powerhouse of the Yingxiuwan Hydropower Station under the Wenchuan earthquake10.1016/j.soildyn.2018.05.027 ↗
3. Implications of strong earthquake ground motion duration on the response and testing of seismic isolation systems10.1002/eqe.3330 ↗
4. Integrated duration effects on seismic performance of concrete gravity dams using linear and nonlinear evaluation methods10.1016/j.soildyn.2015.09.020 ↗
5. Ground Motion Duration Effects on Hysteretic Behavior of Reinforced Concrete Bridge Columns10.1061/(ASCE)ST.1943-541X.0000856 ↗
6. Number of Equivalent Cycles Concept for Liquefaction Evaluations—Revisited10.1061/(ASCE)1090-0241(2005)131:4(477) ↗
7. Damage to mountain tunnels related to the Wenchuan earthquake and some suggestions for aseismic tunnel construction10.1007/s10064-011-0367-6 ↗
8. Seismic damage mechanism and dynamic deformation characteristic analysis of mountain tunnel after Wenchuan earthquake10.1016/j.enggeo.2014.07.017 ↗
9. Assessment of damage in mountain tunnels due to the Taiwan Chi-Chi Earthquake10.1016/S0886-7798(01)00047-5 ↗
10. Seismic damage classification and risk assessment of mountain tunnels with a validation for the 2008 Wenchuan earthquake10.1016/j.soildyn.2012.11.002 ↗
11. Damage observation and assessment of the Longxi tunnel during the Wenchuan earthquake10.1016/j.tust.2016.02.008 ↗
12. Quantitative Classification of Near-Fault Ground Motions Using Wavelet Analysis10.1785/0120060255 ↗
13. Study on elastic response of structures to near-fault ground motions through record decomposition10.1016/j.soildyn.2010.01.009 ↗
14. Characterization and Representation of Near-Fault Ground Motions Using Cumulative Pulse Extraction with Wavelet Analysis10.1785/0120130031 ↗
15. Detection of pulse-like ground motions based on continues wavelet transform10.1007/s10950-010-9193-8 ↗
16. Seismic design and analysis of underground structures10.1016/S0886-7798(01)00051-7 ↗
17. Influence of earthquake ground-motion duration on damage estimation: Application to steel moment resisting frames10.1002/eqe.2769 ↗
18. The Effective Duration Of Earthquake Strong Motion10.1080/13632469909350343 ↗
19. Empirical Equations for the Prediction of the Significant, Bracketed, and Uniform Duration of Earthquake Ground Motion10.1785/0120080298 ↗
20. A general definition of integrated strong motion duration and its effect on seismic demands of concrete gravity dams10.1016/j.engstruct.2016.07.033 ↗
21. Ground motion duration effect on responses of hydraulic shallow-buried tunnel under SV-waves excitations10.1007/s11803-020-0602-x ↗
22. Efficient strong motion duration of pulse-like records for nonlinear structural analyses10.1002/eqe.3249 ↗
23. 3D dynamic response of submerged floating tunnels under seismic and hydrodynamic excitation10.1016/j.engstruct.2007.04.001 ↗
24. Soil–structure interaction effects on seismic inelastic analysis of 3-D tunnels10.1016/j.soildyn.2010.03.010 ↗
25. Impact of incident angles of P waves on the dynamic responses of long lined tunnels10.1002/eqe.2772 ↗
26. Impact of incident angles of earthquake shear (S) waves on 3-D non-linear seismic responses of long lined tunnels10.1016/j.enggeo.2017.03.017 ↗
27. 2-D analysis of circular tunnel against earthquake loading10.1016/j.tust.2005.01.006 ↗
28. 3-D numerical analysis on seismic responses of the underground large scale frame structure under near-fault ground motions10.1016/j.tust.2019.103020 ↗
29. Seismic response of the subway station due to a specific active fault10.1016/j.tust.2018.11.033 ↗
30. Seismic analysis of a long tunnel based on multi-scale method10.1016/j.engstruct.2012.12.021 ↗
31. Mixed finite element methods-Reduced and selective integration techniques: A unification of concepts10.1016/0045-7825(78)90005-1 ↗
32. Effects of near-fault and far-fault ground motions on nonlinear dynamic response and seismic damage of concrete gravity dams10.1016/j.soildyn.2013.07.014 ↗
33. An evaluation of strong motion records and a new parameterA9510.1002/eqe.4290150109 ↗
34. Husid, R.L. (1969). Analisis de Terremoros: Analisis General, Universidad de Chile.
35. Finite Dynamic Model for Infinite Media10.1061/JMCEA3.0001144 ↗
36. Nonlinear dynamic response and damage analysis of hydraulic arched tunnels subjected to P waves with arbitrary incoming angles10.1016/j.compgeo.2019.103358 ↗
37. Optimal selection of scalar and vector-valued intensity measures for improved fragility analysis in cross-fault hydraulic tunnels10.1016/j.tust.2022.104857 ↗
38. Compound intensity measures for improved seismic performance assessment in cross-fault hydraulic tunnels using partial least-squares methodology10.1016/j.tust.2022.104890 ↗
39. 3D viscous-spring artificial boundary in time domain10.1007/s11803-006-0585-2 ↗
40. Inelastic dynamic response and fragility analysis of arched hydraulic tunnels under as-recorded far-fault and near-fault ground motions10.1016/j.soildyn.2020.106070 ↗
41. The analysis of the optimal scalar and vector intensity measurements for seismic performance assessment of deep-buried hydraulic arched tunnels10.1016/j.undsp.2022.07.004 ↗
42. A plastic-damage model for concrete10.1016/0020-7683(89)90050-4 ↗
43. Lifeline Performance10.1193/1.1586197 ↗