A Novel Markerless Lung Tumor-Tracking Method Using Treatment MV Beam Imaging
Source abstract
Abstract
A novel method was developed to track lung tumor motion in real time during radiation therapy with the purpose to allow target radiation dose escalation while simultaneously reducing the dose to sensitive structures, thereby increasing local control without increasing toxicity. This method analyzes beam’s eye view radiation therapy treatment megavoltage (MV) images with simulated digitally reconstructed radiographs (DRRs) as references. Instead of comparing global DRRs with projection images, this method incorporates a technique that divides the global composite DRR and the corresponding MV projection into sub-images called tiles. Registration is performed independently on tile pairs in order to reduce the effects of global discrepancies due to scattering or imaging modality differences. This algorithm was evaluated by phantom studies while simulated tumors were controlled to move with various patterns in a complex humanoid torso. Approximately 15,000 phantom MV images were acquired at nine gantry angles, with different tumors moving within ranges between 10 and 20 mm. Tumors were successfully identified on every projection with a total maximum/average error of 1.84/0.98 mm. This algorithm was also applied to over 5,000 frames of MV projections acquired during radiation therapy of five lung cancer patients. This tumor-tracking methodology is capable of accurately locating lung tumors during treatment without implanting any internal fiducial markers nor delivering extra imaging radiation doses.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
Department of Computer Science, University of Texas at Dallas, Richardson, TX 75080, USA
Department of Radiation Oncology, Henry Ford Hospital, Detroit, MI 48202, USA
Funding
Elekta · Varian Medical Systems
References (20)
Show source-provided references
1. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy10.1016/S0360-3016(02)02803-1 ↗
2. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy10.1016/j.ijrobp.2005.11.016 ↗
3. Radiotherapy of mobile tumors10.1016/j.semradonc.2006.04.007 ↗
4. Tracking moving organs in real time10.1053/j.semradonc.2003.10.005 ↗
5. The management of respiratory motion in radiation oncology report of AAPM Task Group 7610.1118/1.2349696 ↗
6. Tracking moving objects with megavoltage portal imaging: A feasibility study10.1118/1.2191009 ↗
7. Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy10.1088/0031-9155/54/3/013 ↗
8. Fiducial marker and marker-less soft-tissue detection using fast MV fluoroscopy on a new generation EPID: Investigating the influence of pulsing artifacts and artifact suppression techniques10.1118/1.4896116 ↗
9. A multi-region algorithm for markerless beam’s-eye view lung tumor tracking10.1088/0031-9155/55/18/021 ↗
10. Real-Time Markerless Tumor Tracking with MV Imaging and a Dynamic Multi-Leaf Collimator (DMLC)10.1118/1.4735878 ↗
11. Registration of Clinical Volumes to Beams-Eye-View Images for Real-Time Tracking10.1118/1.4815517 ↗
12. Predictor Model Training for Real-Time Motion Management of Lung Tumors10.1118/1.4815294 ↗
13. Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery10.1118/1.4818655 ↗
14. An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images10.1118/1.4889779 ↗
15. The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking10.1118/1.4873322 ↗
16. Combination of Multiple EPID Imager Layers Improves Image Quality and Tracking Performance of Low Contrast Objects10.1118/1.4926300 ↗
17. Tracking tumor boundary in MV-EPID images without implanted markers: A feasibility study10.1118/1.4918578 ↗
18. An accurate algorithm to match imperfectly matched images for lung tumor detection without markers10.1120/jacmp.v16i3.5200 ↗
19. Heckbert, P.S. (1994). Contrast Limited Adaptive Histogram Equalization, Morgan Kaufmann.
20. A Novel Markerless Technique to Evaluate Daily Lung Tumor Motion Based on Conventional Cone-Beam CT Projection Data10.1016/j.ijrobp.2011.11.035 ↗