A Low-Cost, Scalable, and Configurable Multi-Electrode System for Electrical Bio-Interfacing with In-Vitro Cell Cultures
Source abstract
Abstract
Electrical intervention has been one of the prime approaches in therapeutics in recent times. Research studies have reported several instances of electrical intervention in in vitro, in vivo, ex vivo, and clinical experiments. In vitro research shows a direct relationship between applied modulation and changes in a biological entity and leads to proof of theory. Although the stimulus used in in vitro experiments is current, voltage, or electric field, the ionic current flowing through the biological samples is the key factor in biomodulation. The direction and density of ionic current through the biological sample depend heavily on the experimental setup and electrode configuration. Bio-interfacing electrodes within a biological system have been a matter of concern in in vitro experiments, leading to various expensive and commercially available electrode setups. However, most of the setups are tailored for a specific experiment and cannot be altered as required. This paper demonstrates a multi-electrode system designed for in vitro experiments in standard 24-well culture dishes. The electric field distribution and current density of the setup were analyzed using COMSOL Multiphysics. The system is designed using standard PCB building technology. It can be configured into bipolar or tetrapolar setups. The system was used to measure in vitro bio-impedance in a 24-well culture dish for both bipolar and tetrapolar configurations. Bio-compatibility was observed by keeping the system in contact with human dermal fibroblasts (HDFs) in an in vitro experiment environment. The results indicate no statistical difference in the proliferation of HDFs due to exposure to electrodes. Moreover, no corrosion on the electrodes was observed. In general, the system is a low-cost, easy-to-make alternative to commercially available in vitro electrical bio-interfacing studies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: 3D Printing in Biomedical Research · Planarian Biology and Electrostimulation · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Centre for Biomedical Engineering, School of Science and Technology, City, University of London, Northampton Square, London ECIV 0HB, UK
Centre for Applied Vision Research, School of Health and Psychological Sciences, City, University of London, Northampton Square, London ECIV 0HB, UK
Funding
The School of Science and Technology, City, University of London, UK
References (43)
Show source-provided references
1. Electrical stimulation as a novel tool for regulating cell behavior in tissue engineering10.1186/s40824-019-0176-8 ↗
2. Amini, M., Hisdal, J., and Kalvøy, H. (2018). Applications of bioimpedance measurement techniques in tissue engineering. J. Electr. Bioimpedance, 9.10.2478/joeb-2018-0019 ↗
3. Electroporation: Theory and methods, perspectives for drug delivery, gene therapy and research10.1046/j.1365-201X.2003.01093.x ↗
4. Cancer prevention as biomodulation: Targeting the initiating stimulus and secondary adaptations10.1111/j.1749-6632.2012.06736.x ↗
5. Electrical stimulation technologies for wound healing10.1089/wound.2013.0459 ↗
6. In vivo analysis of wound healing by optical methods
7. The effect of magnetic fields on wound healing: Experimental study and review of the literature
8. Effect of negative pressure wound therapy on wound healing10.1067/j.cpsurg.2014.04.001 ↗
9. Physical mechanisms of the therapeutic effect of ultrasound (a review)10.1134/1.1591291 ↗
10. Analgesic electrical stimulation combined with wrist-ankle acupuncture reduces the cortical response to pain in patients with myofasciitis: A randomized clinical trial10.1093/pm/pnac141 ↗
11. Polydopamine-decorated PLCL conduit to induce synergetic effect of electrical stimulation and topological morphology for peripheral nerve regeneration10.1002/smtd.202200883 ↗
12. The effect of electrical stimulation of skeletal muscle on cardioprotection and on muscle-derived myokine levels in rats: A pilot study10.1556/2060.2023.00198 ↗
13. Electrical Stimulation in the Treatment of Pressure Injuries: A Systematic Review of Clinical Trials10.1097/01.ASW.0000926632.19578.b9 ↗
14. Ultrasound-Driven On-Demand Transient Triboelectric Nanogenerator for Subcutaneous Antibacterial Activity10.1002/advs.202204801 ↗
15. Rabbani, M., Rahman, E., Powner, M.B., and Triantis, I.F. (2023). Making Sense of Electrical Stimulation: A Meta-analysis for Wound Healing. Ann. Biomed Eng., 1–25.10.1007/s10439-023-03371-2 ↗
16. Statistical considerations for in vitro research: I—Birth of an idea to collecting data10.1007/s11627-999-0020-2 ↗
17. Statistical considerations for in vitro research: II—Data to presentation10.1007/s11627-999-0021-1 ↗
18. Pijuan, J., Barceló, C., Moreno, D.F., Maiques, O., Sisó, P., Marti, R.M., Macià, A., and Panosa, A. (2019). In vitro cell migration, invasion, and adhesion assays: From cell imaging to data analysis. Front. Cell Dev. Biol., 7.10.3389/fcell.2019.00107 ↗
19. Twelve-well culture plate for the efficient collection and culture of human oocytes and embryos10.1007/BF02066608 ↗
20. Electrical stimulation increases random migration of human dermal fibroblasts10.1007/s10439-017-1849-x ↗
21. Electric fields are novel determinants of human macrophage functions10.1189/jlb.3A0815-390R ↗
22. Antibacterial effects of silver electrodes with weak direct current10.1128/AAC.6.5.637 ↗
23. Efficacy of high voltage pulsed current for healing of pressure ulcers in patients with spinal cord injury10.1093/ptj/71.6.433 ↗
24. Rouabhia, M., Park, H., Meng, S., Derbali, H., and Zhang, Z. (2013). Electrical stimulation promotes wound healing by enhancing dermal fibroblast activity and promoting myofibroblast transdifferentiation. PLoS ONE, 8.10.1371/journal.pone.0071660 ↗
25. The effect of electrical stimulation on the number of mast cells in healing wounds10.1016/0190-9622(91)70171-W ↗
26. Physicochemically tuned myofibroblasts for wound healing strategy10.1038/s41598-019-52523-9 ↗
27. A comparative study of the effects of electrical stimulation and laser treatment on experimental wound healing in rats10.1682/JRRD.2004.02.0147 ↗
28. Role of sensory and motor intensity of electrical stimulation on fibroblastic growth factor-2 expression, inflammation, vascularization, and mechanical strength of full-thickness wounds10.1682/JRRD.2012.04.0074 ↗
29. Anodal and cathodal pulsed electrical stimulation on skin wound healing in guinea pigs10.1682/JRRD.2007.01.0007 ↗
30. Tillotson, D.L., Udale, R.T., Haer, F.A., and Worden, K.L. (2003). Myocyte Culture Pacing Apparatus. (US7148059B1).
31. Development of a miniaturized stimulation device for electrical stimulation of cells10.1186/s13036-015-0012-1 ↗
32. Electrostimulation induces cardiomyocyte predifferentiation of fibroblasts10.1016/j.bbrc.2008.03.115 ↗
33. Accelerated de novo sarcomere assembly by electric pulse stimulation in C2C12 myotubes10.1016/j.yexcr.2007.03.002 ↗
34. Marcelli, E., Bortolani, B., Corazza, I., and Cercenelli, L. (2018). A novel sensorized heart valve prosthesis: Preliminary in vitro evaluation. Sensors, 18.10.3390/s18113905 ↗
35. Urabe, H., Akimoto, R., Kamiya, S., Hosoki, K., Ichikawa, H., and Nishiyama, T. (2023). Pulsed electrical stimulation and amino acid derivatives promote collagen gene expression in human dermal fibroblasts. Cytotechnology, 1–13.10.1007/s10616-023-00604-z ↗
36. Cell culture media: A review10.13070/mm.en.3.175 ↗
37. Animal-cell culture media: History, characteristics, and current issues10.1002/rmb2.12024 ↗
38. Estimation of the Electrical Conductivity of Human Tissue10.1080/027263401752246199 ↗
39. AC Electrothermal Circulatory Pumping Chip for Cell Culture10.1021/acsami.5b08863 ↗
40. Konstantinou, E., Zagoriti, Z., Pyriochou, A., and Poulas, K. (2020). Microcurrent Stimulation Triggers MAPK Signaling and TGF-β1 Release in Fibroblast and Osteoblast-Like Cell Lines. Cells, 9.10.3390/cells9091924 ↗
41. Urbano-Gámez, J.D., Valdés-Sánchez, L., Aracil, C., De la Cerda, B., Perdigones, F., Plaza Reyes, Á., Díaz-Corrales, F.J., Relimpio López, I., and Quero, J.M. (2021). Biocompatibility Study of a Commercial Printed Circuit Board for Biomedical Applications: Lab-on-PCB for Organotypic Retina Cultures. Micromachines, 12.10.3390/mi12121469 ↗
42. The biocompatibility of materials used in printed circuit board technologies with respect to primary neuronal and K562 cells10.1016/j.biomaterials.2009.10.025 ↗
43. Optimum microcurrent stimulation intensity for galvanotaxis in human fibroblasts10.12968/jowc.2012.21.1.5 ↗