The Forces Associated with Bolus Injection and Continuous Infusion Techniques during Ultrasound-Targeted Nerve Contact: An Ex Vivo Study

Ashraf Agweder, Youheng Zeng, Jiatao Liu, Graeme McLeod, Zhihong Huang

Applied Sciences· Volume 14· Issue 7

Abstract

Ultrasound-guided regional anaesthesia with real-time visualization of anatomical structures and needle trajectory has become the standard method for accurately achieving nerve block procedures. Nevertheless, ultrasound is particularly limited in accurately detecting the needle tip in tissues with complex echogenicity. Fat-filled circumneural fascial tissue provides a barrier to local anaesthetic diffusion. Injection during gentle needle nerve contact is more likely to spread under the circumneurium (halo sign). On the other hand, excessive force may cause hematoma or activate the piezo ion channels and intraneural calcium release. Therefore, it is vital to understand the mechanics of needle–tissue interaction for optimizing the procedural outcomes and patients’ safety. We hypothesised that continuous fluid infusion would reduce the needle force applied on the nerve compared to that of bolus injection. Thus, the primary objective of this study was to compare the forces associated with the bolus injection and continuous infusion techniques on the sciatic nerves of fresh lamb legs ex vivo. A needle combining pressure and force was inserted into six legs of lambs ex vivo using a motor stage at a constant velocity and imaged with a linear transducer. Saline injections were block randomised to bolus injection or infusion in the muscle upon gently touching and indenting of the epineurium at nine sites on six sciatic nerves at three angles (30°, 45° and 60°) in each location. The bolus was delivered over 6 s and infused for over 60 s. The result showed less force was generated during the infusion technique when gently touching the epineurium than that of the bolus technique, with p = 0.004, with significant differences observed at a 60° angle (0.49 N, p = 0.001). The injection pressure was also lower when light epineurium touches were applied (9.6 kPa, p = 0.02) and at 60° (8.9 kPa). The time to peak pressure varied across the insertion angles (p < 0.001), with the shortest time at 60° (6.53 s). This study explores future applications by emphasizing the significance of understanding needle–tissue interaction mechanics. This understanding is crucial for optimizing the procedural outcomes and enhancing patients’ safety in ultrasound-guided regional anaesthesia administration. Specifically, continuous infusion demonstrated a notable reduction in needle force compared to that of the bolus injection, especially during gentle epineurium contact.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopedic Surgery and Rehabilitation · Nerve Injury and Rehabilitation · Pain Management and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK

School of Medicine, University of Dundee, Dundee DD2 1SY, UK

Ninewells Hospital, NHS Tayside, Dundee DD2 1SY, UK

Funding

Cultural Affairs Department at the Libyan Embassy, London, UK

References (25)

Show source-provided references
1. Injection pressure monitoring during peripheral nerve blocks: From bench to operating theatre10.1016/j.accpm.2020.03.022 ↗
2. Server, A., Boezaart, A.P., Perez-Carrasco, M., Esteves-Coelho, M., Laredo, F., and Reina, M.A. (2023). Identification of spread after deliberated intraneural injection in five mammalian species: Not all animal models and needle types are valid for studying the effect of intraneural injections in humans. Reg. Anesth. Pain Med.10.1136/rapm-2023-104820 ↗
3. Reducing the risk of neurological complications after peripheral nerve block: What is the role of pressure monitoring?10.1111/anae.14469 ↗
4. Another (Internal) Epineurium: Beyond the Anatomical Barriers of Nerves10.1002/ca.23442 ↗
5. Our best anesthetic blocks are probably related to unintentional and unnoticed intraneural injection10.1136/rapm-2018-100087 ↗
6. Accuracy of injection pressure measurement at peripheral nerves using high-resolution 40 MHz ultrasound in an anesthetized porcine model10.1136/rapm-2022-104282 ↗
7. Microanatomical Nerve Architecture of 6 Mammalian Species: Is Trans-Species Translational Anatomic Extrapolation Valid?
8. Combination of intraneural injection and high injection pressure leads to fascicular injury and neurologic deficits in dogs10.1097/00115550-200409000-00005 ↗
9. Forced needle advancement during needle-nerve contact in a porcine model: Histological outcome10.1213/ANE.0b013e31821b2227 ↗
10. Needle insertion forces and fluid injection pressures during targeting of nerves in a soft embalmed cadaver model10.1007/s10877-021-00680-6 ↗
11. Observations on rotating needle insertions using a brachytherapy robot10.1088/0031-9155/52/19/021 ↗
12. The importance of organ geometry and boundary constraints for planning of medical interventions10.1016/j.medengphy.2008.08.002 ↗
13. Real-time continuous monitoring of injection pressure at the needle tip for peripheral nerve blocks: Description of a new method10.1111/anae.14041 ↗
14. Experiment study on puncture force between MIS suture needle and soft tissue10.1016/j.bsbt.2016.05.001 ↗
15. Cheng, Z., Chauhan, M., Davies, B.L., Caldwell, D.G., and Mattos, L.S. (2015, January 25–29). Modelling needle forces during insertion into soft tissue. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.
16. Analysis of Dynamic Tissue Deformation during Needle Insertion into Soft Tissue
17. Ko, S.Y., Davies, B.L., and Rodriguez YBaena, F. (2010, January 18–22). Two-dimensional needle steering with a “programmable bevel” inspired by nature: Modeling preliminaries. Proceedings of the 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems, Taipei, Taiwan.
18. Althobaiti, M., Ali, S., Hariri, N.G., Hameed, K., Alagl, Y., Alzahrani, N., Alzahrani, S., and Al-Naib, I. (2023). Recent Advances in Smart Epidural Spinal Needles. Sensors, 23.10.3390/s23136065 ↗
19. Challenges, solutions, and advances in ultrasound-guided regional anaesthesia10.1093/bjaed/mkw026 ↗
20. Perioperative nerve injury and regional anaesthesia
21. Validation of the soft-embalmed Thiel cadaver as a high-fidelity simulator of pressure during targeted nerve injection10.1136/rapm-2020-102132 ↗
22. Objective Epidural Space Identification Using Continuous Real-Time Pressure Sensing Technology: A Randomized Controlled Comparison with Fluoroscopy and Traditional Loss of Resistance10.1213/ANE.0000000000003873 ↗
23. Evaluation of the B-Smart manometer and the CompuFlo computerized injection pump technology for accurate needle-tip injection pressure measurement during peripheral nerve blockade10.1136/rapm-2018-000026 ↗
24. Yang, C., Xie, Y., Liu, S., and Sun, D. (2018). Force modeling, identification, and feedback control of robot-assisted needle insertion: A survey of the literature. Sensors, 18.10.3390/s18020561 ↗
25. Lei, Y., Du, S., Li, M., Xu, T., Hu, Y., and Wang, Z. (2024). Needle-tissue interaction model based needle path planning method. Comput. Methods Programs Biomed., 243.10.1016/j.cmpb.2023.107858 ↗