Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive
Source abstract
Abstract
Operating overvoltage occurs when the pantograph or main breaker of an electric locomotive is operated, which is prone to causing insulation failure of high-voltage equipment. The HXD1 electric locomotive is taken as the research object in this paper to explore the characteristics and influencing factors of operating overvoltage. Under pantograph lifting, main breaker closing, main breaker opening, and pantograph dropping, operating overvoltage waveform in the high-voltage system is recorded by a high-speed oscilloscope and resistance–capacitance voltage divider to analyze the overvoltage characteristics and distribution law. Tested data show that the amplitude of operating overvoltage is in the range of 80 to 330 kV with ultra-high steepness, which is similar to the Very Fast Transient Overvoltage (VFTO) in power systems. The maximum overvoltage during the entire test occurred during the main breaker closing and its amplitude is 328.60 kV with a steepness of 4.21 × 104 kV/μs. The max overvoltage of the other operations (pantograph lifting, main breaker opening, and pantograph dropping) are 280.60 kV, 194.73 kV, and 305.56 kV with ultra-high steepness. High-amplitude overvoltage is predominantly located at the pantograph, while the low-amplitude sort is mainly observed around other high-voltage equipment. The result indicates that operating overvoltage belongs to ultra-fast transient overvoltage and its amplitude and steepness are higher than existing research.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Systems and Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
References (23)
Show source-provided references
1. Data analysis of high voltage transformer for HXD1B locomotive
2. Fault and analysis of high voltage transformer in HXD3C electric locomotive
3. The impact of high-speed railway catenary and pantograph off-line overvoltage on vehicle potential
4. Discussion on the lightning arrester and discharge gap burnout failure of HXD21000 series locomotives
5. Shi, D. (2015). Research on Switching Overvoltage and Its Suppression Technique for High Voltage System of the Electrical Multiple Units Train. [Master’s Thesis, Department of Electrical Engineering, Beijing Jiaotong University].
6. Research on Overvoltage Generation Mechanism and Test of Traction Power Grid
7. Liu, Y. (2021). Research on Electromagnetic Disturbance Characteristics of Pantograph-Catenary Offline and Pantograph Lifting. [Master’s Thesis, Department of Electrical Engineering, Southwest Jiaotong University].
8. Wang, S. (2022, January 27–29). Research on testing and simulation analysis of overvoltage waveform on the roof of a moving train. Proceedings of the 2022 IEEE 5th International Electrical and Energy Conference (CIEEC), Nanjing, China.10.1109/CIEEC54735.2022.9846469 ↗
9. Research on VFTO Simulation Analysis of 1000 kV GIS Test Circuit Considering Dynamic Arcing Model10.1109/TIA.2022.3193908 ↗
10. (2011). Standard for High-Voltage Test Techniques—Part 1: General Definitions and Test Requirements (Standard No. GB/T 16927-2011).
11. (2018). Standard for Specification for 1100 kV Alternating-Current Disconnectors and Earthing Switches (Standard No. GB/T 24837-2018).
12. (2004). Standard for Computational Guide to Insulation Co-Ordination and Modelling Of Electrical Networks (Standard No. IEC 60071-4).
13. Shi, W., Chang, Y., and Zhang, Q. (2010). Fundamentals of High Voltage Engineering, China Machine Press.
14. Shen, Q., Zhou, Z., and Wang, D. (2012). High Voltage Technology, China Electric Power Press. [4th ed.].
15. He, X. (2002). Electrical Appliances, China Machine Press. [2nd ed.].
16. Lin, S. (2011). Modern High Voltage Electrical Apparatus Technology, China Machine Press. [2nd ed.].
17. Song, K. (2018). Research on VFTO Simulation in Disconnecting Switch Time-Varying Capacitance Model. [Master’s Thesis, Department of Electrical Engineering, Huazhong University of Scince & Technology].
18. Qiao, Z. (2012). Overvoltage and Electrical Insulation Protection in Power System, China Coal Industry Publishing House. [1st ed.].
19. Zhao, Z. (2022). High Voltage Technique, China Electric Power Press. [Chinese ed.].
20. Zhang, S. (2009). HXD1 Electric Locomotive, China Railway Publishing House.
21. Wu, M. (2016). Transient Processes and Optimization of Winding Insulation for Power Transformer. [Master’s Thesis, Department of Electrical Engineering, Southwest University].
22. (2021). Metal-Oxide Surge Arresters Without Gaps for a.c. Systems (Standard No. GB/T 11032-2020).
23. The V-A characteristics under steep-front waves of metal oxide surge arrester model