Effectiveness of Using a Patient Simulator with Real-Time Feedback to Improve Light-Curing Skills of Dental Students
Source abstract
Abstract
The present study investigated the effectiveness of employing a patient simulator with an integrated visual feedback mechanism to improve the light-curing skills of dental students. A total of 44 third-year dental students were randomly divided into a control group (n = 22) and a training group (n = 22). Both groups light-cured a simulated restoration in tooth 27 in a patient simulator (MARC Patient Simulator, BlueLight Analytics, Halifax, Canada) by using the same curing device for 10 s. Delivered irradiances were recorded in real time by the built-in spectrophotometer. After measuring the baseline irradiances for both groups, the training group received detailed light-curing instructions and hands-on training with immediate visual feedback using the patient simulator. The irradiance of the training group was re-measured after the training. Both groups then attended a 26-day preclinical course, which involved placing 30 composite restorations. Upon completion of this course, the light-curing performance of both groups was re-assessed. The data were statistically analyzed using the Wilcoxon signed-rank test, Friedman’s ANOVA, and the Mann-Whitney U-test at an overall level of significance of α = 0.05. At baseline, the control and the training group delivered statistically similar irradiances with similar data scattering. In the training group, data scattering was considerably reduced after the hands-on training with the patient simulator. After the 26-day preclinical course, the irradiance of the training group was significantly higher and considerably less scattered compared to the control group. In conclusion, training with the patient simulator improved the light-curing performance of the dental students, mainly by helping them to deliver light energy more consistently.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Research and COVID-19 · Dental materials and restorations · Dental Health and Care Utilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland
Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
Funding
Foundation for Research in Science and the Humanities at the University of Zurich
References (33)
Show source-provided references
1. The teaching of posterior resin composites: Planning for the future based on 25 years of research10.1016/j.jdent.2014.02.014 ↗
2. Clinical effectiveness of direct class II restorations—A meta-analysis
3. Margin integrity of conservative composite restorations after resin infiltration of demineralized enamel
4. Enamel wear by antagonistic restorative materials under erosive conditions10.1007/s00784-017-2071-9 ↗
5. Demineralized enamel reduces margin integrity of self-etch, but not of etch-and-rinse bonded composite restorations10.1007/s10266-018-0398-6 ↗
6. Polymerization shrinkage and shrinkage force kinetics of high- and low-viscosity dimethacrylate- and ormocer-based bulk-fill resin composites10.1007/s10266-018-0369-y ↗
7. Selection of dental materials and longevity of replaced restorations in Public Dental Health clinics in northern Sweden10.1016/j.jdent.2009.04.010 ↗
8. Survival of direct resin restorations in posterior teeth within a 19-year period (1996–2015): A meta-analysis of prospective studies10.1016/j.dental.2015.05.004 ↗
9. Influence of irradiant energy on degree of conversion, polymerization rate and shrinkage stress in an experimental resin composite system10.1016/j.dental.2008.01.006 ↗
10. Curing potential of experimental resin composites with systematically varying amount of bioactive glass: Degree of conversion, light transmittance and depth of cure10.1016/j.jdent.2018.06.004 ↗
11. Correlation between light intensity and exposure time on the hardness of composite resin10.1023/A:1008981907601 ↗
12. Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites10.1007/s00784-014-1302-6 ↗
13. Bracket bond strength dependence on light power density10.1016/j.jdent.2005.11.006 ↗
14. Influence of light intensity on dentin bond strength of self-etch systems10.2334/josnusd.48.21 ↗
15. Wear and marginal breakdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
16. The influence of light-curing time on the bacterial colonization of resin composite surfaces10.1016/j.dental.2009.02.012 ↗
17. Resin composites in dentistry: The monomer systems10.1111/j.1600-0722.1997.tb00188.x ↗
18. Wegehaupt, F.J., Tauböck, T.T., Attin, T., and Belibasakis, G.N. (2014). Influence of light-curing mode on the cytotoxicity of resin-based surface sealants. BMC Oral Health, 14.10.1186/1472-6831-14-48 ↗
19. Genotoxic potential of dental bulk-fill resin composites10.1016/j.dental.2017.04.011 ↗
20. Quantifying light energy delivered to a Class I restoration
21. Dieckmann, P., Mohn, D., Zehnder, M., Attin, T., and Tauböck, T.T. (2019). Light transmittance and polymerization of bulk-fill composite materials doped with bioactive micro-fillers. Materials, 12.10.3390/ma12244087 ↗
22. Degree of conversion of experimental resin composites containing bioactive glass 45S5: The effect of post-cure heating10.1038/s41598-019-54035-y ↗
23. The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites10.1038/s41598-020-67641-y ↗
24. Curing potential of experimental resin composites filled with bioactive glass: A comparison between Bis-EMA and UDMA based resin systems10.1016/j.dental.2020.03.015 ↗
25. Computer-assisted dental simulation as a predictor of preclinical operative dentistry performance10.1002/j.0022-0337.2011.75.9.tb05169.x ↗
26. Evaluating the efficiency of the Dental Teacher system as a digital preclinical teaching tool10.1111/eje.12365 ↗
27. Factors affecting the energy delivered to simulated class I and class V preparations
28. Improving light-curing instruction in dental school10.1002/j.0022-0337.2013.77.6.tb05528.x ↗
29. Bulk-fill resin composites: Polymerization properties and extended light curing10.1016/j.dental.2014.12.010 ↗
30. Longevity of posterior composite restorations: Not only a matter of materials10.1016/j.dental.2011.09.003 ↗
31. Longevity of direct restorations in Dutch dental practices. Descriptive study out of a practice based research network10.1016/j.jdent.2016.01.002 ↗
32. Curing-light intensity and depth of cure of resin-based composites tested according to international standards10.14219/jada.archive.2002.0200 ↗
33. Influence of increment thickness on radiant energy and microhardness of bulk-fill resin composites10.4012/dmj.2017-032 ↗