Does Pressurized Carbon Dioxide Lavage Improve Bone Cleaning in Cemented Arthroplasty?
Source abstract
Abstract
Cemented implant fixation in total joint arthroplasty has been proven to be safe and reliable with good long-term results. However, aseptic loosening is one of the main reasons for revision, potentially caused by poor cementation with low penetration depth in the cancellous bone. Aim of this prospective laboratory study was, to compare impact pressure and cleaning effects of pulsatile saline lavage to novel carbon dioxide lavage in a standardized carbon foam setup, to determine whether or not additional use of carbon dioxide lavage has any impact on cleaning volume or cleaning depth in cancellous bone. Carbon specimens simulating human cancellous bone were filled with industrial grease and then underwent a standardized cleaning procedure. Specimens underwent computed tomography pre- and post-cleaning. Regarding the impact pressure, isolated carbon dioxide lavage showed significant lower pressure compared to pulsatile saline lavage. Even though the combination of carbon dioxide lavage and pulsatile saline lavage had a positive cleaning effect compared to the isolated use of pulsatile saline lavage or carbon dioxide lavage, this was not significant in terms of cleaning volume or cleaning depth.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Clinic for Orthopedic and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
Clinic for Orthopedics and Trauma Surgery, Kepler University Hospital, 4020 Linz, Austria
References (46)
Show source-provided references
1. Cementless total knee arthroplasty: Current concepts review10.1302/0301-620X.98B7.37367 ↗
2. Twenty-Five-Years and Greater, Results After Nonmodular Cemented Total Knee Arthroplasty10.1016/j.arth.2016.01.043 ↗
3. Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases10.1080/000164700317413067 ↗
4. The Swedish Total Hip Replacement Register10.2106/00004623-200200002-00002 ↗
5. Has the Use of Fixation Techniques in THA Changed in This Decade? The Uncemented Paradox Revisited10.1097/CORR.0000000000001117 ↗
6. Grimberg, A., Jansson, V., Melsheimer, O., and Steinbrück, A. (2021, June 30). German Arthroplasty Registry (EPRD)—2019 Annual Report. Available online: https://www.eprd.de/fileadmin/user_upload/Dateien/Publikationen/Berichte/EPRD_Jahresbericht_2019_EN_doppelseitig_F_Web-Stand-251120.pdf.
7. (2014). The New Zealand Joint Registry—Fifteen Year Report January 1999 to December 2013, NZOA. Available online: https://nzoa.org.nz/sites/default/files/NZJR2014Report.pdf.
8. Population-based 10-year cumulative revision risks after hip and knee arthroplasty for osteoarthritis to inform patients in clinical practice: A competing risk analysis from the Dutch Arthroplasty Register10.1080/17453674.2021.1876998 ↗
9. Robertsson, O. (2020). The Swedish Knee Arthroplasty Register—Anual Report 2020, Skånes University Hospital.
10. Cementing technique for primary knee arthroplasty: A scoping review10.1080/17453674.2019.1657333 ↗
11. Niculescu, M., Solomon, B.L., Viscopoleanu, G., Antoniac, I.V., Viscopoleanu, G., and Antoniac, I.V. (2016). Evolution of Cementation Techniques and Bone Cements in Hip Arthroplasty. Handbook of Bioceramics and Biocomposites, Springer International Publishing.10.1007/978-3-319-12460-5_42 ↗
12. The epidemiology of failure in total knee arthroplasty: Avoiding your next revision10.1302/0301-620X.98B1.36293 ↗
13. Predictive factors of aseptic loosening of cemented total hip prostheses
14. The protective effect of pulsed lavage against implant subsidence and micromotion for cemented tibial unicompartmental knee components: An experimental cadaver study10.1016/j.arth.2013.09.020 ↗
15. Cementing technique and the effects of bleeding10.1302/0301-620X.69B4.3611170 ↗
16. Comparing Cementing Techniques in Total Knee Arthroplasty: An In Vitro Study10.1055/s-0038-1669917 ↗
17. Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures
18. Aseptic Loosening at the Tibia in Total Knee Arthroplasty: A Function of Cement Mantle Quality?10.1016/j.arth.2020.02.028 ↗
19. Cementing techniques for the tibial component in primary total knee replacement10.1302/0301-620X.95B3.29586 ↗
20. The effect of thickness and pressure on the curing of PMMA bone cement for the total hip joint replacement10.1016/0021-9290(80)90014-7 ↗
21. Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: Pulsed lavage versus syringe lavage10.1007/s00264-009-0736-y ↗
22. Lavage technique in total hip arthroplasty: Jet lavage produces better cement penetration than syringe lavage in the proximal femur10.1054/arth.2000.8098 ↗
23. The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement10.2106/JBJS.K.01116 ↗
24. Tibial cleaning method for cemented total knee arthroplasty: An experimental study10.4103/0019-5413.106887 ↗
25. An experimental comparison of different devices for pulsatile high-pressure lavage and their relevance to cement intrusion into cancellous bone10.1007/s00402-007-0418-4 ↗
26. Granick, M.S., Tenenhaus, M., Knox, K.R., and Ulm, J.P. (2007). Comparison of wound irrigation and tangential hydrodissection in bacterial clearance of contaminated wounds: Results of a randomized, controlled clinical study. Ostomy Wound Manag., 53.
27. Pulsatile irrigation in orthopedics10.3928/0147-7447-19850801-13 ↗
28. The measurement and comparison of jet characteristics of surgical pulse lavage devices10.1054/arth.2003.50009 ↗
29. Goldstein, W.M., Gordon, A., Goldstein, J.M., Berland, K., Branson, J., and Sarin, V.K. (2007, January 28). Improfement of Cement mantle thickness with pressurized carbon dioxide lavage. Proceedings of the 20th Annual Meeting of the International Society for Technology in Arthroplasty 2007, Paris, France.
30. Effectiveness Testing of Combined Innovative Pressurized Carbon Dioxide Lavage and Pulsatile Normal Saline Irrigation to Enhance Bone Cement Penetration in Total Knee Replacement: A Cadaveric Study
31. The Effect of Tourniquet Use and Sterile Carbon Dioxide Gas Bone Preparation on Cement Penetration in Primary Total Knee Arthroplasty10.1016/j.arth.2019.03.050 ↗
32. Bone-cement interface strength in distal radii using two medullary canal preparation techniques: Carbon dioxide jet cleaning versus syringed saline10.1142/S0218810410004618 ↗
33. Gas embolism after the use of the CarboJet lavage system during hip hemiarthroplasty. Clinical case and literature review
34. Air embolism after cleaning the intramedullary canal with a high pressure CO2 wash in hip fracture
35. Cement applicator use for hip resurfacing arthroplasty10.1016/j.medengphy.2015.02.007 ↗
36. Cementing techniques for hip resurfacing arthroplasty: Development of a laboratory model10.2106/JBJS.H.00622 ↗
37. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability10.1016/j.neuroimage.2006.01.015 ↗
38. Pulsed lavage improves fixation strength of cemented tibial components10.1007/s00264-010-1137-y ↗
39. Increased initial cement-bone interlock correlates with reduced total knee arthroplasty micro-motion following in vivo service10.1016/j.jbiomech.2014.04.016 ↗
40. Influence of bone density on the cement fixation of femoral hip resurfacing components10.1002/jor.21094 ↗
41. Primary Total Knee Arthroplasty Performed Using High-Viscosity Cement is Associated With Higher Odds of Revision for Aseptic Loosening10.1016/j.arth.2019.08.023 ↗
42. Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery10.1186/s13018-015-0320-7 ↗
43. Pulsatile Lavage of Musculoskeletal Wounds Causes Muscle Necrosis and Dystrophic Calcification in a Rat Model10.2106/JBJS.17.00330 ↗
44. High-pressure pulsatile lavage causes soft tissue damage10.1097/01.blo.0000144859.73074.45 ↗
45. High pressure pulsatile lavage of contaminated human tibiae: An in vitro study10.1097/00005131-199809000-00009 ↗
46. High-pressure pulsatile lavage propagates bacteria into soft tissue10.1097/01.blo.0000182246.37454.b2 ↗