Using Full Pose Measurement for Serial Robot Calibration
Source abstract
Abstract
To ensure smooth robot operations, parameters of its kinematic model and a registration transformation between robot base and world coordinate frame must be determined. Both tasks require data acquired by external sensors that can measure either 3D locations or full 6D poses. We show that use of full pose measurements leads to much smaller robot orientation errors when compared with the outcome of calibration and registration procedures based on 3D data only. Robot position errors are comparable for both types of data. The conclusion is based on extensive simulations of 7 degrees of freedom robot arm and different levels of pseudo-noise perturbing both positional and rotational components of pose.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Robotic Mechanisms and Dynamics · Robot Manipulation and Learning · Advanced Vision and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Intelligent Systems Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
References (34)
Show source-provided references
1. Marvel, J., Messina, E., Antonishek, B., Fronczek, L., and Wyk, K.V. (2015). NISTIR 8093: Tools for Collaborative Robots within SME Workcells, Technical Report.
2. Kinematic-parameter identification for serial-robot calibration based on POE formula10.1109/TRO.2010.2047529 ↗
3. An overview of robot calibration10.1109/JRA.1987.1087124 ↗
4. The calibration index and taxonomy for robot kinematic calibration methods10.1177/027836499601500604 ↗
5. An overview of robot calibration10.3923/itj.2004.74.78 ↗
6. Chen, H., Fuhlbrigge, T., Choi, S., Wang, J., and Li, X. (2008, January 23–26). Practical industrial robot zero offset calibration. Proceedings of the 2008 IEEE International Conference on Automation Science and Engineering, Arlington, VA, USA.
7. Absolute calibration of an ABB IRB 1600 robot using a laser tracker10.1016/j.rcim.2012.06.004 ↗
8. Computationally efficient and robust kinematic calibration methodologies and their application to industrial robots10.1016/j.rcim.2015.06.003 ↗
9. Plane kinematic calibration method for industrial robot based on dynamic measurement of double ball bar10.1016/j.precisioneng.2019.12.010 ↗
10. Dynamic error compensation for industrial robot based on thermal effect model10.1016/j.measurement.2016.02.038 ↗
11. Application-oriented selection of poses and forces for robot elastostatic calibration10.1016/j.mechmachtheory.2020.104176 ↗
12. Ma, L.M., Fong, T., Micire, M.J., Kim, Y.K., and Feigh, K. (2018). Human-Robot teaming: Concepts and components for design. Field and Service Robotics, Springer.
13. Non-kinematic calibration of a six-axis serial robot using planar constraints10.1016/j.precisioneng.2014.12.002 ↗
14. Non-kinematic calibration of industrial robots using a rigid–flexible coupling error model and a full pose measurement method10.1016/j.rcim.2018.07.002 ↗
15. Online absolute pose compensation and steering control of industrial robot based on six degrees of freedom laser measurement10.1117/1.OE.56.3.034111 ↗
16. An error-similarity-based robot positional accuracy improvement method for a robotic drilling and riveting system10.1007/s00170-016-8975-8 ↗
17. A compensation method based on error similarity and error correlation to enhance the position accuracy of an aviation drilling robot10.1088/1361-6501/aacd6e ↗
18. Using locally adjustable hand-eye calibrations to reduce robot localization error10.1007/s42452-020-2626-2 ↗
19. Computational aspects of the product-of-exponentials formula for robot kinematics10.1109/9.280779 ↗
20. A screw axis identification method for serial robot calibration based on the POE model10.1108/01439911211201609 ↗
21. Laser tracker-based kinematic parameter calibration of industrial robots by improved CPA method and active retroreflector10.1007/s00170-012-4484-6 ↗
22. Conrad, K.L., Shiakolas, P.S., and Yih, T. (2000, January 17–19). Robotic calibration issues: Accuracy, repeatability and calibration. Proceedings of the 8th Mediterranean Conference on Control and Automation (MED2000), Rio, Patras, Greece.
23. Choi, Y., Cheong, J., Kyung, J.H., and Do, H.M. (2016, January 19–22). Zero-offset calibration using a screw theory. Proceedings of the 2016 13th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), Xi’an, China.10.1109/URAI.2016.7625770 ↗
24. Geometric calibration of industrial robots using enhanced partial pose measurements and design of experiments10.1016/j.rcim.2015.03.007 ↗
25. Posada, D.J., Schneider, U., Pidan, S., Geravand, M., Stelzer, P., and Verl, A. (2016, January 16–21). High Accurate Robotic Drilling with External Sensor and Compliance Model-Based Compensation. Proceedings of the IEEE International Conference on Robotics and Automation, Stockholm, Sweden.
26. Online pose correction of an industrial robot using an optical coordinate measure machine system
27. Automated Fiber Placement Path Planning: A state-of-the-art review10.14733/cadaps.2019.172-203 ↗
28. A new full pose measurement method for robot calibration10.3390/s130709132 ↗
29. Absolute robot calibration with a single telescoping ballbar10.1016/j.precisioneng.2014.01.001 ↗
30. Least-Squares Fitting of Two 3-D Point Sets10.1109/TPAMI.1987.4767965 ↗
31. Means and averaging in the group of rotations10.1137/S0895479801383877 ↗
32. The Fisher-Bingham Distribution on the Sphere10.1111/j.2517-6161.1982.tb01189.x ↗
33. The axes of random infinitesimal rotations and the propagation of orientation uncertainty10.1016/j.measurement.2015.04.020 ↗
34. Lipkin, H. (2005, January 24–28). A note on Denavit-Hartenberg notation in robotics. Proceedings of the ASME International Design Engineering Technical Conferences & Computers and Information in Engineering Conference, Long Beach, CA, USA.10.1115/DETC2005-85460 ↗