journal article·2022-05-23Open access

Interaction Effect of Room Size and Opening on Trombe Wall Performance in Sichuan–Tibet Alpine Valley Areas

Lili Zhang, Jingyue Cheng, Fei Liu, Haolin Li, Zhuojun Dong, Xuemei Zhang, Kai Wang, Lei Tian, Haoru Liu, Jiangjun Wan, Congshan Tian

Applied Sciences· Volume 12· Issue 10

Abstract

The Trombe wall (T-wall) system is one of the most effective systems for passive solar energy utilization technology, which is of great significance for the alleviation of the energy crisis and the protection of the environment. Taking as an example Tibetan dwellings in the Sichuan–Tibet alpine valley which have installed T-walls for heating, the effects of the length of the room (Factor A), the width of the room (Factor B), the width of the opening on the north wall of the room (Factor C), and the distance from the lower edge of the opening to the floor (Factor D) on the indoor air temperature and room energy consumption are studied by orthogonal experiment and numerical simulation. Results show that the four factors all have a significant effect on the two analysis indicators. The rankings of the factors are consistent for their impact on the two analysis indicators, as, in both cases, Factor A > Factor B > Factor C > Factor D. Therefore, the influence of room configuration cannot be ignored in the optimization of T-wall design. Additionally, the optimal parameter combination for the highest indoor temperature and low energy consumption in winter is also proposed. This research can further improve the study of T-walls, and provide a reference for the thermal environment design of buildings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Solar Energy Systems and Technologies · Wind and Air Flow Studies · Building Energy and Comfort Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Architecture and Urban-Rural Planning, Dujiangyan Campus, Sichuan Agricultural University, Dujiangyan 611830, China

Funding

National Natural Science Foundation of China

References (42)

Show source-provided references
1. Experimental study on thermal performance of an integrated PCM Trombe wall10.1016/j.renene.2020.10.081 ↗
2. Numerical and experimental study on the performance of a Photovoltaic Trombe wall system with Venetian blinds10.1016/j.energy.2020.119542 ↗
3. Numerical simulation and sensitivity analysis on an improved Trombe wall
4. Experimental study of the influence of collector height on the steady state performance of a passive solar air heater10.1016/j.solener.2010.05.018 ↗
5. The behaviour of solar walls in residential buildings with different insulation levels: An experimental and numerical study10.1016/j.enbuild.2011.11.039 ↗
6. Passive ventilation and heating by natural convection in a multi-storey building10.1016/S0360-1323(02)00070-7 ↗
7. Experimental study of the heating performance of a Trombe wall with a new design10.1016/j.solener.2015.06.002 ↗
8. Thermal energy storage and losses in a room-Trombe wall system located in Mexico10.1016/j.energy.2016.04.122 ↗
9. Influence of Trombe wall on indoor thermal environment of a two-story building in rural Northern China during summer10.1080/23744731.2018.1550994 ↗
10. Study on a high-performance photocatalytic-Trombe wall system for space heating and air purification10.1016/j.apenergy.2018.05.111 ↗
11. The performance analysis of a novel TC-Trombe wall system in heating seasons10.1016/j.enconman.2018.02.093 ↗
12. The performance analysis of a novel hybrid solar gradient utilization photocatalytic-thermal-catalytic-Trombe wall system10.1016/j.energy.2019.02.121 ↗
13. Performance analysis of a purified Trombe wall with ventilation blinds based on photo-thermal driven purification10.1016/j.apenergy.2019.113846 ↗
14. The performance analysis of a purified PV/T-Trombe wall based on thermal catalytic oxidation process in winter10.1016/j.enconman.2019.112262 ↗
15. The performance analysis on a novel purification-cleaning trombe wall based on solar thermal sterilization and thermal catalytic principles10.1016/j.energy.2021.120275 ↗
16. An approach for energy conscious renovation of residential buildings in Istanbul by Trombe wall system10.1016/j.buildenv.2006.11.033 ↗
17. Energy conservation in honey storage building using Trombe wall10.1016/j.enbuild.2008.02.019 ↗
18. Optimizing energy and environmental performance of passive Trombe wall10.1016/j.enbuild.2013.11.062 ↗
19. Energy and exergy analysis of different Trombe walls10.1016/j.enbuild.2016.04.052 ↗
20. Three-dimensional simulation on the thermal performance of a novel Trombe wall with venetian blind structure10.1016/j.enbuild.2014.12.014 ↗
21. Trombe wall for a residential building in Sichuan-Tibet alpine valley—A case study10.1016/j.renene.2020.04.067 ↗
22. Influence of constructive and operating parameters on a modified Trombe wall efficiency10.1016/S1644-9665(12)60080-6 ↗
23. A numerical and experimental analysis of the air vent management and heat storage characteristics of a trombe wall10.1016/j.solener.2013.01.016 ↗
24. Heat gain through Trombe wall using solar energy in a cold region of Turkey
25. A numerical and experimental study of a dual-function solar collector integrated with building in passive space heating mode10.1007/s11434-010-3117-4 ↗
26. Optimum design of Trombe wall system in mediterranean region10.1016/j.solener.2011.04.025 ↗
27. The Effect of Changing Trombe Wall Component on the Thermal Load10.1016/j.egypro.2012.05.181 ↗
28. Numerical study of a modified Trombe wall solar collector system10.2298/TSCI0901195D ↗
29. CFD analysis of heat collection in a glazed gallery10.1016/j.enbuild.2010.08.023 ↗
30. Thermal performance of a passive test room with a Trombe wall in Tunisia10.1063/1.4705523 ↗
31. Theoretical models for wall solar chimney under cooling and heating modes considering room configuration10.1016/j.energy.2018.10.037 ↗
32. An empirical model to predict the performance of typical solar chimneys considering both room and cavity configurations10.1016/j.buildenv.2016.04.024 ↗
33. Interaction effect of room opening and air inlet on solar chimney performance10.1016/j.applthermaleng.2019.113877 ↗
34. Teaching–learning-based metaheuristic scheme for modifying neural computing in appraising energy performance of building10.1007/s00366-020-00981-5 ↗
35. Moayedi, H., and Mosavi, A. (2021). Double-Target Based Neural Networks in Predicting Energy Consumption in Residential Buildings. Energies, 14.10.3390/en14051331 ↗
36. Moayedi, H., and Mosavi, A. (2021). Suggesting a Stochastic Fractal Search Paradigm in Combination with Artificial Neural Network for Early Prediction of Cooling Load in Residential Buildings. Energies, 14.10.20944/preprints202101.0133.v1 ↗
37. Employing artificial bee colony and particle swarm techniques for optimizing a neural network in prediction of heating and cooling loads of residential buildings10.1016/j.jclepro.2020.120082 ↗
38. Ventilated Trombe wall as a passive solar heating and cooling retrofitting approach; a low-tech design for off-grid settlements in semi-arid climates10.1016/j.solener.2015.10.005 ↗
39. (2016). Code for Thermal Design of Civil Building (GB 50176-2016), China Architecture & Building Press.
40. Brief Introduction to the Orthogonal Test Design
41. U.S. Department of Energy (2021, January 20). EnergyPlus Version 8.9.0, Available online: https://energyplus.net/.
42. China Academy of Building (2013). Design Standard for Energy Efficiency of Rural Residential Buildings (GB/T 50824-2013), China Architecture & Building Press.