Predictive Model for the Optimized Mixed-Air Temperature of a Single-Duct VAV System
Source abstract
Abstract
As global warming accelerates due to greenhouse gas emissions, more efforts are required to reduce greenhouse gas emissions. One of the methods used to save building energy is the efficient management of building mechanical systems. The economizer control of HVAC systems is an energy-efficient measure that improves operating methods by introducing outdoor air to save cooling energy when the outdoor-air temperature is sufficiently low. When the HVAC system is operated using economizer control, cooling energy can be saved, and the set-point of the mixed-air temperature is kept constant. Several studies are being conducted on the saving of energy using economizers. Although various studies have been conducted on the control of economizers, there is insufficient research dealing with the optimal control of mixed-air temperature in economizers that consider real-time changes. Therefore, in this study, predictive model-based mixed-air temperature optimization for a single-duct VAV system was constructed. For this, an ANN (Artificial Neural Network) that could be analyzed regardless of the variables was applied to predict the load and energy consumption and a simulator was constructed for the optimized mixed air temperature of the system. The predictive model-based control was evaluated in terms of its thermal comfort and energy, along with the existing economizer control. According to the application of the optimal economizer control, the energy consumption of the building was reduced by 28.9% compared to the existing dry-bulb temperature control, and was within ±1 °C of the indoor-air temperature set point.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Building Energy and Comfort Optimization · Diverse Academic Research Analysis · Energy and Environmental Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Architectural Engineering, Graduate School of Yeungnam University, Gyeongsan 38541, Korea
School of Architecture, Yeungnam University, Gyeongsan 38541, Korea
Funding
Yeungnam University
References (23)
Show source-provided references
1. Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions
2. The Development of a Rule-Based Fault Detection and Diagnostic System to Use for the Economizing of HVAC Systems
3. Comparison of Cooling-Energy Performance Depending on the Economizer-Control Methods in an Office Building
4. A Study on the Analysis of Energy Consumption According to Economizer Control Method10.21086/ksles.2016.04.23.2.251 ↗
5. A study on Performance Evaluation of Economizer Type through Simulation in Office
6. Cooling energy performance analysis depending on the economizer cycle control methods in an office building10.1016/j.enbuild.2016.03.073 ↗
7. Energy analysis on VAV system with different air-side economizers in China10.1016/j.enbuild.2010.02.013 ↗
8. An energy performance study of several factors in air economizers with low-limit space humidity10.1016/j.enbuild.2013.05.025 ↗
9. Air handling unit supply air temperature optimal control during economizer cycles10.1016/j.enbuild.2012.02.024 ↗
10. Lee, J., Kim, Y., Jo, J., Cho, H., and Cho, Y. (2018). Development of Economizer Control Method with Variable Mixed Air Temperature. Energies, 11.10.3390/en11092445 ↗
11. A Logical Calculus of Ideas Immanent in Nervous Activity10.1007/BF02478259 ↗
12. Predicting of the Geothermal Heat Pump System Coefficient of Performance using Artificial Neural Network10.21086/ksles.2017.10.24.5.562 ↗
13. Predicting energy consumption for residential buildings using ANN through parametric modeling10.1016/j.egyr.2021.04.053 ↗
14. Building’s electricity consumption prediction using optimized artificial neural networks and principal component analysis10.1016/j.enbuild.2015.09.002 ↗
15. Comparative study of a building energy performance software (KEP-IYTE-ESS) and ANN-based building heat load estimation10.1016/j.enbuild.2014.09.026 ↗
16. In-situ application of an ANN algorithm for optimized chilled and condenser water temperatures set-point during cooling operation10.1016/j.enbuild.2020.110666 ↗
17. Development of Performance Prediction Model for Water Source Heat Pump System based on Artificial Neural Network
18. Development of an Artificial Neural Network Model for a Predictive Control of Cooling Systems
19. MathWorks (MATLAB, 2020). MATLAB, version 2020b.
20. U.S. Department of Energy (2022). EnergyPlus Engineering Reference. The Reference to EnergyPlus Calculations, U.S. Department of Energy.
21. Hitchcock, R.J., and Carroll, W.L. (2003, January 11–14). Delight: A daylighting and electric lighting simulation engine. Proceedings of the 8th International IBPSA Conference, Eindhoven, The Netherlands.
22. Wetter, M. (2016). Building Controls Virtual Test Bed, Lawrence Berkeley National Laboratory.
23. ASHRAE (2014). ASHRAE’s Guideline 14, Measurement of Energy, Demand and Water Savings, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.