journal article·2024-01-30Open access

A New Method for Defining the Optimal Separation Gap Distance and the Acceptable Structural Pounding Risk on Multistory RC Structures

Maria G. Flenga, Maria J. Favvata

Applied Sciences· Volume 14· Issue 3

Abstract

A proposal to control the structural pounding hazard imposed on multistory reinforced concrete (RC) structures is presented. The main goal is to guarantee the seismic performance of a structure with an acceptable (predefined) risk-targeted parameter without the need to eliminate structural pounding collisions. The key target parameters of this study are the annual probability of exceeding an engineering demand parameter (EDP) capacity level and the separation distance dg between adjacent structures. In this direction, a method that ensures the performance level of critical EDPs due to structural pounding conditions is proposed. The new method involves two decision frameworks that define (a) the optimal separation gap distance dg,minPt at a targeted value of pounding risk (probability per year) Pt (Decision A) and (b) the minimum acceptable structural pounding risk Pmindg,t at a targeted value of separation gap distance dg,t (Decision B). The demand parameters that are incorporated in the proposed method are the peak relative displacement δmax at the top level of colliding without considering pounding conditions and any other critical EDP due to the structural pounding effect. The overall method is based on two distinct acceptable performance objectives, the POs-δmax and the POs-EDP, defined as a function of P vs. dg. For this purpose, a seismic hazard curve compatible with Eurocode’s 8 hazard zone is adopted, and the corresponding demand hazard curves of δmax and EDP are developed. The proposed method is implemented to study the floor-to-floor structural pounding hazard of an eight-story RC frame taking into account different risk-targeted scenarios. The results show that the seismic risk (probability per year) of exceeding the EDP’s capacity level is significantly increased due to structural pounding in comparison to the case of no pounding. Calibration of the structural pounding risk can be obtained by adjusting the separation gap distance dg between the adjacent structures based on the acceptable POs. The POs-δmax is not always an accurate criterion for verifying the capacity level of the critical EDP. Finally, with the proposed method, a variety of POs-EDPs can be used to control the structural pounding risk in terms of dg,minPt and/or Pmindg,t.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Civil Engineering Department, University of Patras, 26504 Patras, Greece

References (43)

Show source-provided references
1. Earthquake-induced interaction between adjacent reinforced concrete structures with non-equal heights10.1002/eqe.398 ↗
2. Pounding of buildings in series during earthquakes10.1002/eqe.4290160311 ↗
3. Lagrange multiplier solution method for pounding of buildings during earthquakes10.1002/eqe.4290201102 ↗
4. An investigation of earthquake induced pounding between adjacent buildings10.1002/eqe.4290210402 ↗
5. Assessment of damage due to earthquake-induced pounding between the main building and the stairway tower10.4028/www.scientific.net/KEM.347.339 ↗
6. Building pounding damage observed in the 2011 Christchurch earthquake10.1002/eqe.1164 ↗
7. Structural performance of a base-isolated reinforced concrete building subjected to seismic pounding10.1002/eqe.2158 ↗
8. Structural pounding between adjacent buildings subjected to strong ground motions. Part I: The effect of different structures arrangement10.1002/eqe.2285 ↗
9. Mitigation measures for earthquake induced pounding effects on seismic performance of adjacent buildings10.1007/s10518-014-9592-2 ↗
10. Pounding between inelastic three-storey buildings under seismic excitations10.4028/www.scientific.net/KEM.665.121 ↗
11. Minimum required separation gap for adjacent RC frames with potential interstory seismic pounding10.1016/j.engstruct.2017.09.025 ↗
12. Numerical simulation of potential seismic pounding among adjacent buildings in series10.1007/s10518-018-0455-0 ↗
13. Probabilistic seismic demand model for pounding risk assessment10.1002/eqe.2725 ↗
14. A probabilistic performance-based approach for mitigating the seismic pounding risk between adjacent buildings10.1002/eqe.2267 ↗
15. Probabilistic seismic assessment of the pounding risk based on the local demands of a multistory RC frame structure10.1016/j.engstruct.2021.112789 ↗
16. Critical building separation distance in reducing pounding risk under earthquake excitation10.1016/S0167-4730(02)00080-2 ↗
17. Probability analysis of seismic pounding of adjacent buildings10.1002/eqe.78 ↗
18. Assessment of the separation necessary to prevent seismic pounding between linear structural systems10.1016/j.probengmech.2008.06.002 ↗
19. Evaluation of current criteria in predicting the separation necessary to prevent seismic pounding between nonlinear hysteretic structural systems10.1016/j.engstruct.2009.01.016 ↗
20. Tubaldi, E., Freddi, F., and Barbato, M. (2013, January 16–20). Probabilistic seismic demand and fragility assessment for evaluating the separation distance between adjacent buildings. Proceedings of the 11th International Conference on Structural Safety and Reliability, New York, NY, USA.
21. Probabilistic risk analysis of structural impact in seismic events for linear and nonlinear systems10.1002/eqe.2414 ↗
22. Probabilistic evaluation of separation distance between two adjacent structures
23. Investigating the effects of structural pounding on the seismic performance of adjacent RC and steel MRFs10.1007/s10518-020-00985-y ↗
24. Incremental dynamic analysis and fragility assessment of buildings founded on different soil types experiencing structural pounding during earthquakes10.1016/j.engstruct.2021.113118 ↗
25. Multivariate Probabilistic Seismic Demand Model for the Bridge Multidimensional Fragility Analysis10.1007/s12205-018-0414-y ↗
26. Structural System Reliability Analysis Based on Improved Explicit Connectivity BNs10.1007/s12205-018-1289-7 ↗
27. Mohamed, H., and Romão, X. (2021). Seismic Fragility Functions for Non-Seismically Designed RC Structures Considering Pounding Effects. Buildings, 11.10.3390/buildings11120665 ↗
28. Flenga, M.G., and Favvata, M.J. (2021). Fragility Curves and Probabilistic Seismic Demand Models on the Seismic Assessment of RC Frames Subjected to Structural Pounding. Appl. Sci., 11.10.3390/app11178253 ↗
29. Flenga, M.G., and Favvata, M.J. (2023). The effect of magnitude Mw and distance Rrup on the fragility assessment of a multistory RC frame due to earthquake-induced structural pounding. Buildings, 13.10.3390/buildings13071832 ↗
30. Towards high-precision data modeling of SHM measurements using an improved sparse Bayesian learning scheme with strong generalization ability10.1177/14759217231170316 ↗
31. Probabilistic Basis for 2000 SAC Federal Emergency Management Agency Steel Moment Frame Guidelines10.1061/(ASCE)0733-9445(2002)128:4(526) ↗
32. Alternative non-linear demand estimation methods for probability-based seismic assessments10.1002/eqe.876 ↗
33. IM-based and EDP-based decision models for the verification of the seismic collapse safety of buildings10.1002/eqe.2923 ↗
34. A simplified risk-targeted decision model for the verification of the seismic performance of critical infrastructure components to the operational limit state10.1016/j.engstruct.2019.110019 ↗
35. A probabilistic performance-based risk assessment approach for seismic pounding with efficient application to linear systems10.1016/j.strusafe.2012.01.002 ↗
36. Probabilistic performance-based assessment for critical separation distance of adjacent buildings: Theoretical analysis10.1061/(ASCE)CF.1943-5509.0001453 ↗
37. Predicting the seismic collapse capacity of adjacent structures prone to pounding10.1139/cjce-2018-0725 ↗
38. A risk-targeted decision model for the verification of the seismic performance of RC structures against structural pounding10.1016/j.soildyn.2023.108229 ↗
39. Jalayer, F., and Cornell, C.A. (2003). A Technical Framework for Probability-Based Demand and Capacity Factor Design (DCFD) Seismic Formats, University of California. PEER 2003/08.
40. (2004). Eurocode 2. Design of Concrete Structures. Part 1. 1: General Rules and Rules for Buildings (Standard No. EN 1992-1-1).
41. (2004). Eurocode 8. Design of Structures for Earthquake Resistance. Part 1: General Rules, Seismic Actions and Rules for Buildings (Standard No. EN 1998-1).
42. Prakash, V., Powell, G.H., and Campbell, S. (1993). DRAIN-2DX Base Program Description and User’s Guide, UCB/SEMM, University of California. Report No. 17/93.
43. (2017, February 10). PEER Ground Motion Database. Available online: https://peer.berkeley.edu/peer-strong-ground-motion-databases.