Fabrication of Edge Rounded Polylactic Acid Biomedical Stents by the Multi-Axis Micro-Milling Process
Source abstract
Abstract
This paper presents the first try to fabricate degradable polylactic acid (PLA) biomedical stents with round edges by the multi-axis micro-milling process. Conventionally biomedical stents are produced by laser processing. Post-processing operations are usually required to handle sharp edges and thermal defects of the stent due to laser processing. A computer graphics software package was used to design the strut structures with round corners of the PLA stent. A PLA tube was first created using injection molding, and a degradable biomedical stent was then fabricated through micro-milling by using a five-axis computer numerical control (CNC) machine tool. This study investigated the error in the rotation center that can occur during five-axis micro-milling. Data obtained from experiments on center-of-rotation errors were substituted into homogeneous coordinate conversion formulas. Center-of-rotation errors in the five-axis machine tool were compensated for improving the milling precision (A and C axes) to be within 5 μ m. Furthermore, milling parameter optimization experiments were conducted, which determined the optimal conditions for milling PLA to be a spindle speed of 60,000 rpm, feed per tooth of 0.005 mm, and feed rate of 600 mm/min, and achieved the minimum burr 0.01 mm and the average surface roughness (Ra) 0.4 μ m. These optimal cutting parameters will be used in the following actual stent processing experiments. Finally, the error compensation and optimal parameters were combined in a CAM software package and layered spiral micromilling to machine the actual stent. The experimental results revealed that the combination of five-axis micro-milling led to the successful fabrication of a degradable biomedical stent (stent diameter = 6 mm, strut width = 0.3 mm, and radius at round corners = 0.1 mm). The machined actual stent had cross-section height and width errors within 0.01 mm, and arc depth of cut variation within 6 μ m. In addition, the PLA stent machining results indicated a rebound of approximately 33% at the strut round edge machining. This work may also open up future possibilities for complex three-dimensionally structured biomedical stents for better performance and special functionality.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, National Taiwan University of Science and Technology, No. 43, Keelung Rd., Sec. 4, Taipei 10607, Taiwan
References (32)
Show source-provided references
1. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
2. Shape memory alloys
3. A survey of stent designs10.1080/136457002760273340 ↗
4. Micromachining NiTi tubes for use in medical devices by using a femtosecond laser10.1016/j.optlaseng.2014.08.001 ↗
5. Curve micromachining on the edges of nitinol biliary stent by ultrashort pulses laser10.1016/j.optlastec.2016.10.018 ↗
6. Liu, Z.W. (2015). Development of Post Treatment for Biomedical Nitinol Stents. [Master’s Thesis, National Taiwan University of Science and Technology].
7. Impact and tensile properties of PLA/Cordenka and PLA/flax composites10.1016/j.compscitech.2008.01.004 ↗
8. An overview of polylactides as packaging materials10.1002/mabi.200400043 ↗
9. Processing technologies for poly (lactic acid)10.1016/j.progpolymsci.2008.05.004 ↗
10. An overview of the recent developments in polylactide (PLA) research10.1016/j.biortech.2010.05.092 ↗
11. Wang, J.S. (2013). A Geometry Driven Approach to Improving the Cutting Performance of Five-Axis Tool Paths. [Master’s Thesis, National Taiwan University of Science and Technology].
12. NC post-processor for 5-axis milling machine of table-rotating/ tilting type10.1016/S0924-0136(02)00725-2 ↗
13. Postprocessor development of a five-axis machine tool with nutating head and table configuration10.1007/s00170-007-1126-5 ↗
14. Development of a five-axis postprocessor system with a nutating head10.1016/j.jmatprotec.2006.11.101 ↗
15. Liao, M.Y. (2005). Using DBB for Measuring and Calibrating Gemetric Errors of 5-Axis CNC Machine Tools. [Master’s Thesis, National Tsing Hua University].
16. A simple method for testing measuring machines and machine tools10.1016/0141-6359(82)90018-6 ↗
17. Sono, M., Sakaida, Y., Kawai, T., and Takeuchi, Y. (2005, January 9–14). Development of tool setting error compensation method for 5-axis control ultraprecision machining. Proceedings of the 20th Annual ASPE Meeting, Norfolk, VA, USA.
18. Effect of diamond tool sharpness on minimum cutting thickness and cutting surface integrity in ultraprecision machining10.1016/S0924-0136(96)02429-6 ↗
19. Investigation of micro-cutting operations10.1016/j.ijmachtools.2005.05.015 ↗
20. Understanding and quantification of elastic and plastic deformation during a scratch test10.1016/S0043-1648(98)00200-2 ↗
21. 5-axis micro milling machine for machining micro parts10.1007/s00170-003-1950-1 ↗
22. Effect of machining velocity in nanoscale machining operations
23. Eckman, N., Saigal, A., and James, T.P. (2012, January 22–27). Determination of cutting edge separation point during micromachining of highly elastic materials. Proceedings of the 15th International Conference on Experimental Mechanics, Porto, Portugal.
24. Ultraprecision machining of polymers10.1016/0141-6359(93)90105-J ↗
25. The role of viscous deformation in the machining of polymers10.1016/S0020-7403(02)00178-9 ↗
26. Mechanical Properties of a Biodegradable Balloon-expandable Stent from Poly(l-lactide) for Peripheral Vascular Applications10.1115/1.2355683 ↗
27. Fabrication of a polymer-based biodeg-radable stent using a CO2 laser10.1016/j.acme.2013.08.005 ↗
28. Wang, C.H. (2002). Study of Properties and Cell Culture of Small-Diameter Synthetic PLA/PCL Vascular Scaffold via Electrospinning. [Master’s Thesis, National Chiao Tung University].
29. Teng, P.T. (2014). Development of Biodegradable Polylactide Graft Stent Using Circular Thermal Imprint. [Ph.D. Thesis, National Taiwan University of Science and Technology].
30. Kao, C.L. (2017). Development of 5-French Nitinol Biliary Stents. [Master’s Thesis, National Taiwan University of Science and Technology].
31. Sheikh-Ahmad, J.Y. (2009). Machining of Polymer Composites, Springer.10.1007/978-0-387-68619-6 ↗