High Voltage Ride through Strategy of Wind Farm Considering Generator Terminal Voltage Distribution
Source abstract
Abstract
When wind power is transmitted via high-voltage direct current (HVDC), the problem of high-voltage ride-through (HVRT), caused by direct-current (DC) blocking must be seriously taken into account. All the wind turbines in a wind farm are usually equivalent to a single turbine in the existing research on HVRT, which ignores the generator terminal voltage distribution in a wind farm. In view of the fact that the severity of fault voltage felt by each wind turbine in the field is different, an improved HVRT strategy considering voltage distribution is proposed in this article. First, this article analyzes the mechanism of voltage swell failure caused by DC blocking, and the characteristics of the generator terminal voltage distribution in wind farms. Second, the reactive power characteristic equations of the synchronous condenser and the doubly-fed induction generator (DFIG) are derived. Third, based on the extraction of the key node voltage, this article takes the key node voltage as the compensation target, and put forwards a HVRT strategy combining the synchronous condenser and wind turbine. Finally, the simulation is carried out to demonstrate the effectiveness of the proposed strategy in improving the HVRT capability of all wind turbines.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: HVDC Systems and Fault Protection · Wind Turbine Control Systems · Microgrid Control and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical Engineering, Southeast University, Nanjing 210096, China
Xinjiang Electric Power Research Institute, Urumqi 830000, China
Funding
Science and Technology Project of State Grid Xinjiang Electrical Power co. Ltd.
References (25)
Show source-provided references
1. Lee, J., Yoo, Y., Yoon, M., and Jang, G. (2019). Advanced Fault Ride-Through Strategy by an MMC HVDC Transmission for Off-Shore Wind Farm Interconnection. Appl. Sci., 9.10.3390/app9122522 ↗
2. Impact of Inertia and Effective Short Circuit Ratio on Control of Frequency in Weak Grids Interfacing LCC-HVDC and DFIG-Based Wind Farms10.1109/TPWRD.2016.2607205 ↗
3. Raza, A., Shakeel, A., Altalbe, A.O., Alassafi, M., and Yasin, A.R. (2020). Impacts of MT-HVDC Systems on Enhancing the Power Transmission Capability. Appl. Sci., 10.10.3390/app10010242 ↗
4. Zhang, Z., Lee, J., and Jang, G. (2020). Improved Control Strategy of MMC–HVDC to Improve Frequency Support of AC System. Appl. Sci., 10.10.3390/app10207282 ↗
5. Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators10.1109/TEC.2010.2081365 ↗
6. Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions10.6113/JPE.2015.15.1.235 ↗
7. Improved Ride-Through Control of DFIG During Grid Voltage Swell
8. High-voltage Ride Through Strategy for DFIG Considering Converter Blocking of HVDC System10.35833/MPCE.2019.000321 ↗
9. Wind farm HVRT capability improvement based on coordinated reactive power control strategy
10. Qin, B., Li, H., Zhou, X., Li, J., and Liu, W. (2020). Low-Voltage Ride-Through Techniques in DFIG-Based Wind Turbines: A Review. Appl. Sci., 10.10.3390/app10062154 ↗
11. Comparative study of STATCOM and SVC performance on Dynamic Voltage Collapse of an Electric Power System with Wind Generation10.1109/TLA.2014.6749530 ↗
12. Low Voltage Ride Through of Wind Farms with Cage Generators: STATCOM versus SVC10.1109/TPEL.2008.921169 ↗
13. Comparative Study of SVC and STATCOM Reactive Power Compensation for Prosumer Microgrids with DFIG-Based Wind Farm Integration10.1109/ACCESS.2020.3033058 ↗
14. Research on capacity configuration method of concentrated reactive power compensator for wind farm LVRT capability
15. Coordinated control of reactive power and voltage for wind farm aiming at voltage stability of PCC and generator terminal
16. Dynamic Performance Comparison of Synchronous Condenser and SVC10.1109/TPWRD.2007.916109 ↗
17. Comparison of New Generation Synchronous Condenser and Power Electronic Reactive-Power Compensation Devices in Application in UHV DC/AC Grid
18. Optimal Allocation of Synchronous Condensers in Wind Dominated Power Grids10.1109/ACCESS.2020.2977941 ↗
19. Coordinated control for improving the HVRT capability of a DFIG wind farm using a synchronous condenser
20. Investigation on the Combined Effect of VSC-Based Sources and Synchronous Condensers under Grid Unbalanced Faults10.1109/TPWRD.2019.2914342 ↗
21. Impact of VSC Control Strategies and Incorporation of Synchronous Condensers on Distance Protection under Unbalanced Faults10.1109/TIE.2018.2835389 ↗
22. A Coordinated HVRT Strategy of Large-Scale Wind Power Transmitted with HVDC System
23. GB/T 19963-2011 Technical Rule for Connecting Wind Farm to Power System
24. Analysis of Voltage Control Strategies for Wind Farms10.1109/TSTE.2019.2915667 ↗
25. Fault ride-through of renewable energy conversion systems during voltage recovery10.1007/s40565-015-0177-0 ↗