journal article·2021-05-19Open access

Implementation of Portable Automatic Tourniquet with High-Elasticity Biocompatible Strap

Seong Tak Woo, Cheol Woo Park, Ji Hyun Sung, Cheol-Min Park

Applied Sciences· Volume 11· Issue 10

Abstract

The most common screening techniques to diagnose a patient’s illness are blood collection and intravenous procedures. To find a collection or injection site, conventional blood collection support tools, such as latex tubing and buckle-type tourniquets, are generally used to compress the patient’s blood vessels. This conventional passive method has significant problems such as latex allergy, vulnerability to site contamination and potential bloodstream infection, and physical damage due to improper use. To overcome the disadvantages of conventional blood collection support tools, an automatic tourniquet with a high-elasticity biocompatible strap was constructed. The automatic tourniquet is designed to automatically adjust the strap length using a motor to control the pressure according to the body dimensions of patients. In order to evaluate the performance of the automatic tourniquet, blood flow characteristics were analyzed using an ultrasound measurement system. The results demonstrated that the automatic tourniquet showed better performance compared with those of other blood collection support tools.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Blood transfusion and management · Intravenous Infusion Technology and Safety · Blood donation and transfusion practices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronic Engineering, Dong Seoul University, 76 Bokjeong-ro, Sujeong-gu, Seongnam-si 13117, Korea

Medivice Incorporated, 61 Daehak-ro, Gumi 39177, Korea

R&D Center, Medivice Incorporated, 60 Beoman-ro, Suseong-gu, Daegu 42242, Korea

Mechanical Components and Materials R&D Group, Korea Institute of Industrial Technology (KITECH), 320 Techno Sunhwan-ro, Daegu 42994, Korea

School of Materials Science and Engineering, Kumoh National Institute of Technology, 61 Daehak-ro, Gumi 39177, Korea

Department of Energy Engineering Convergence, Kumoh National Institute of Technology, 61 Daehak-ro, Gumi 39177, Korea

Funding

National Research Foundation of Korea (NRF) funded by the Ministry of Education · Grand Information Technology Research Center Program through the Institute of Information & Communications Technology and Planning & Evaluation (IITP) funded by the Ministry of Science and ICT (MSIT)

References (28)

Show source-provided references
1. Survival with Emergency Tourniquet Use to Stop Bleeding in Major Limb Trauma10.1097/SLA.0b013e31818842ba ↗
2. Effect of Tourniquet Use on Activation of Coagulation in Total Knee Replacement10.1097/00003086-200002000-00021 ↗
3. The arterial tourniquet: Pathophysiological consequences and anaesthetic implications10.1046/j.1365-2044.2001.01982.x ↗
4. Tourniquet Safety in Lower Leg Applications10.1097/00006416-200209000-00009 ↗
5. Low pressure pneumatic tourniquets: Effectiveness at minimum recommended inflation pressures
6. Surgical Tourniquets in Orthopaedics10.2106/JBJS.I.00634 ↗
7. Evaluation of Commercial Latex as a Positive Control for In Vitro Testing of Bioceramics10.4028/www.scientific.net/KEM.631.357 ↗
8. Mechanical and biological comparison of latex and silicone rubber bands10.1016/S0889-5406(03)00564-X ↗
9. Parreira, P., Serambeque, B., Costa, P.S., Monico, L.S., Oliveira, V., Sousa, L.B., Gama, F., Bernardes, A.R., Adriano, D., and Marques, A.I. (2019). Impact of an Innovative Securement Dressing and Tourniquet in Peripheral Intravenous Catheter-Related Complications and Contamination: An Interventional Study. Int. J. Environ. Res. Public Health, 16.10.3390/ijerph16183301 ↗
10. Tourniquets used in peripheral venipuncture as a potential vehicle for transmission of microorganisms: Scoping review10.22354/in.v24i2.839 ↗
11. Health professionals’ practices related with tourniquet use during peripheral venipuncture: A scoping review
12. Prevention of latex allergy among health care workers and in the general population: Latex protein content in devices commonly used in hospitals and general practice10.1007/s00420-005-0080-5 ↗
13. Primary prevention of natural rubber latex allergy in the German health care system through education and intervention10.1067/mai.2002.126461 ↗
14. Natural rubber latex allergy among health care workers: A systematic review of the evidence10.1016/j.jaci.2006.03.048 ↗
15. Latex allergy: Diagnosis and management
16. Patient Safety: Latex Allergy10.1016/j.suc.2005.09.014 ↗
17. Dhillion, B.S. (2000). Medical Device Reliability and Associated Areas, CRC Press.10.1201/9781420042238 ↗
18. Webster, J.G. (2008). Medical Instrumentation Application and Design, John Wiley and Sons Inc.
19. Biocompatibility and Fatigue Properties of Polystyrene, Polyisobutylene, Polystyrene, an Emerging Thermoplastic Elastomeric Biomaterial10.1021/bm050971c ↗
20. Rapid isothermal substrate microfabrication of a biocompatible thermoplastic elastomer for cellular contact guidance10.1016/j.actbio.2011.02.019 ↗
21. Biomedical Application of Commercial Polymers and Novel Polyisobutylene-Based Thermoplastic Elastomers for Soft Tissue Replacement10.1021/bm034513k ↗
22. Cephalic Vein Measurement before Forearm Fistula Creation: Does Use of a Tourniquet to Meet the Venous Diameter Threshold Increase the Number of Usable Fistulas?10.7863/jum.2006.25.12.1541 ↗
23. Mid-arm approach to basilic and cephalic vein cannulation using ultrasound guidance10.1093/bja/aeh179 ↗
24. Blood flow measurements in arteriovenous dialysis fistulas
25. Local blood flow characteristics of arteriovenous fistulas in the forearm for dialysis
26. Tourniquet Use in a Civilian Emergency Medical Services Setting: A Descriptive Analysis of the Boston EMS Experience10.3109/10903127.2014.995842 ↗
27. Evaluation of Possible Tourniquet Systems for Use in the Canadian Forces10.1097/01.ta.0000215429.94483.a7 ↗
28. The Military Emergency Tourniquet Program’s Lessons Learned with Devices and Designs10.7205/MILMED-D-11-00114 ↗