journal article·2021-10-21Open access

An Aerosol Sensor for Multi-Sized Particles Detection Based on Surface Acoustic Wave Resonator and Cascade Impactor

Zhiyuan Chen, Jiuling Liu, Minghua Liu, Ran You, Shitang He

Applied Sciences· Volume 11· Issue 21

Abstract

This research proposed the design, fabrication, and experiments of a surface acoustic wave resonator (SAWR)-based multi-sized particles monitor. A wide range selection and monitoring of large coarse particles (LCP), inhalable particles (PM10), and fine inhalable particles (PM2.5) were achieved by combining high-performance 311 MHz SAWRs and a specially designed cascade impactor. This paper calculated the normalized sensitivity distribution of the chip to the mass loading effect, extracted the optimal response area for particle attachment, analyzed the influence of the distance between nozzle and chip surface on the particle distribution, and evaluated the collection efficiency of the specially designed 2 LPM (L/min) impactor through computational fluid dynamics simulation software. An experimental platform was built to conduct the response experiment of the sensor to particle-containing gas generated by the combustion of leaf fragments and repeatability test. We verified the results of the particle diameter captured at each stage. This research suggests that the sensor’s response had good linearity and repeatability, while the particles collected on the surface of the SAWR in each impactor stage met the desired diameter, observed through a microscope.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Acoustic Wave Resonator Technologies · Gas Sensing Nanomaterials and Sensors · Air Quality Monitoring and Forecasting

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Acoustics, Chinese Academy of Sciences, No. 21, North 4th Ring West Road, Beijing 100190, China

School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China

Funding

National Natural Science Foundation of China

References (26)

Show source-provided references
1. Chronic PM2.5 Exposure and Inflammation: Determining Sensitive Subgroups in Mid-Life Women10.1016/j.envres.2014.03.042 ↗
2. Lavigne, É., Talarico, R., van Donkelaar, A., Martin, R.V., Stieb, D.M., Crighton, E., Weichenthal, S., Smith-Doiron, M., Burnett, R.T., and Chen, H. (2021). Fine Particulate Matter Concentration and Composition and the Incidence of Childhood Asthma. Environ. Int., 152.10.1016/j.envint.2021.106486 ↗
3. Lee, D.-W., Han, C., Hong, Y.-C., Oh, J.-M., Bae, H.-J., Kim, S., and Lim, Y.-H. (2021). Long-Term Exposure to Fine Particulate Matter and Incident Asthma among Elderly Adults. Chemosphere, 272.10.1016/j.chemosphere.2021.129619 ↗
4. Particulate Matter (PM2.5, PM10-2.5, and PM10) and Children’s Hospital Admissions for Asthma and Respiratory Diseases: A Bidirectional Case-Crossover Study10.1080/15287390801907459 ↗
5. World Health Organization (2006). Air Quality Guidelines: Global Update 2005: Particulate Matter, Ozone, Nitrogen Dioxide, and Sulfur Dioxide, World Health Organization.
6. Monitoring of Particulate Matter Outdoors10.1016/S0045-6535(02)00270-9 ↗
7. Sensors and ‘Apps’ for Community-Based Atmospheric Monitoring
8. Comparison of Real-Time Instruments Used To Monitor Airborne Particulate Matter10.1080/10473289.2001.10464254 ↗
9. On Waves propagated along the Plane Surface of an Elastic Solid
10. Direct Piezoelectric Coupling to Surface Elastic Waves10.1063/1.1754276 ↗
11. Surface Acoustic-wave Piezoelectric Crystal Aerosol Mass Microbalance10.1063/1.1140980 ↗
12. Wang, X., Wang, Y., and Li, H. (2014). Development of a New Surface Acoustic Wave Based Pm2.5 Monitor, IEEE.
13. An Aerosol Sensor for PM1 Concentration Detection Based on 3D Printed Virtual Impactor and SAW Sensor10.1016/j.sna.2019.01.013 ↗
14. Kuo, F.-Y., Lin, Y.-C., Ke, L.-Y., Tsai, C.-J., and Yao, D.-J. (2018). Detection of Particulate Matter of Size 2.5 Μm with a Surface-Acoustic-Wave Sensor Combined with a Cyclone Separator. Micromachines, 9.10.3390/mi9080398 ↗
15. Airborne Particulate Matter Classification and Concentration Detection Based on 3D Printed Virtual Impactor and Quartz Crystal Microbalance Sensor10.1016/j.sna.2015.12.029 ↗
16. Djoumi, L., Vanotti, M., and Blondeau-Patissier, V. (2018). Real Time Cascade Impactor Based On Surface Acoustic Wave Delay Lines for PM10 and PM2.5 Mass Concentration Measurement. Sensors, 18.10.3390/s18010255 ↗
17. Configuration of Air Microfluidic Chip for Separating and Grading Respirable Dust
18. (1995). SAW Gas Sensors: Comparison between Delay Line and Two Port Resonator. Sens. Actuators B Chem., 26, 187–190.10.1016/0925-4005(94)01583-4 ↗
19. Rapp, M., Reibel, J., Stahl, U., Stier, S., and Voigt, A. (1998, January 27–29). Influence of Phase Position on the Chemical Response of Oscillator Driven Polymer Coated SAW Resonators. Proceedings of the 1998 IEEE International Frequency Control Symposium (Cat. No.98CH36165), Pasadena, CA, USA.
20. Acoustic Fields and Waves in Solids: Two Volumes 110.1063/1.3128926 ↗
21. Coupling-of-Modes Analysis of Saw Devices10.1142/S0129156400000684 ↗
22. Hao, W., Liu, J., Liu, M., Liang, Y., and He, S. (2016). Mass Sensitivity Optimization of a Surface Acoustic Wave Sensor Incorporating a Resonator Configuration. Sensors, 16.10.3390/s16040562 ↗
23. Baron, P.A., Kulkarni, P., and Willeke, K. (2011). Aerosol Measurement: Principles, Techniques, and Applications, Wiley. [3rd ed.].10.1002/9781118001684 ↗
24. Performance of Bioaerosol Samplers: Collection Characteristics and Sampler Design Considerations10.1016/0960-1686(92)90166-I ↗
26. Zhang, N. (2018). Study on the Characteristics of Particulate Emissions from Eight Typical Indoor or Outdoor Combustion Behaviors, Zhejiang Normal University.