journal article·2021-07-01Open access

Dose Estimation by Geant4-Based Simulations for Cone-Beam CT Applications: A Systematic Review

Ana M. Cabanas, Mauricio Arriagada-Benítez, Carlos Ubeda, Oliver Meseguer-Ruiz, Pedro Arce

Applied Sciences· Volume 11· Issue 13

Abstract

The last two decades have witnessed increasing use of X-ray imaging and, hence, the exposure of humans to potentially harmful ionizing radiation. Computed tomography accounts for the largest portion of medically-related X-ray exposure. Accurate knowledge of ionizing radiation dose from Cone-Beam CT (CBCT) imaging is of great importance to estimate radiation risks and justification of imaging exposures. This work aimed to review the published evidence on CBCT dose estimation by focusing on studies that employ Geant4-based toolkits to estimate radiation dosage. A systematic review based on a scientometrics approach was conducted retrospectively, from January 2021, for a comprehensive overview of the trend, thematic focus, and scientific production in this topic. The search was conducted using WOS, PubMed, and Scopus databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. In total, 93 unique papers were found, of which only 34 met the inclusion criteria. We opine that the findings of this study provides a basis to develop accurate simulations of CBCT equipment for optimizing the trade-off between clinical benefit and radiation risk.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Dose and Imaging · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Departamento de Física, Universidad de Tarapacá, Arica 1010064, Chile

Facultad de Ingeniería, Universidad de Tarapacá, Arica 1010064, Chile

FACSAL, Universidad de Tarapacá, Arica 1010064, Chile

Departamento de Ciencias Históricas y Geograficás, Universidad de Tarapacá, Iquique 1113642, Chile

Unidad de Aplicaciones Médicas, CIEMAT, 28040 Madrid, Spain

Funding

UNIVERSIDAD DE TARAPACÁ

References (100+)

Show source-provided references
1. Advanced X-ray Imaging Technology10.1007/978-3-030-42618-7_1 ↗
2. Cone-beam computed tomography with a flat-panel imager: Initial performance characterization10.1118/1.599009 ↗
3. Flat-panel cone-beam computed tomography for image-guided radiation therapy10.1016/S0360-3016(02)02884-5 ↗
4. C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology10.1016/j.jvir.2008.02.002 ↗
5. Clinical applications of cone-beam computed tomography in dental practice
6. Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure10.1016/j.ijrobp.2008.10.006 ↗
7. Cone-beam CT for radiotherapy applications10.1088/0031-9155/40/11/007 ↗
8. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning10.1118/1.2795842 ↗
9. Percutaneous Transthoracic Lung Biopsy: Comparison between C-Arm Cone-Beam CT and Conventional CT Guidance10.1016/j.tranon.2015.04.006 ↗
10. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 18010.1002/mp.12824 ↗
11. Imaging dose from cone beam computed tomography in radiation therapy10.1016/j.ejmp.2015.06.003 ↗
12. Evaluation of Ultra-low-dose Paediatric Cone-beam Computed Tomography for Image-guided Radiotherapy10.1016/j.clon.2020.09.011 ↗
13. Cone-beam CT diagnostic applications: Caries, periodontal bone assessment, and endodontic applications10.1016/j.cden.2008.05.002 ↗
14. The importance of cone-beam computed tomography in the management of endodontic problems: A review of the literature10.1016/j.joen.2014.05.009 ↗
15. Application of cone beam computed tomography for assessment of the temporomandibular joints10.1111/j.1834-7819.2011.01663.x ↗
16. Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality10.2214/AJR.08.1017 ↗
17. Characterization of scatter in cone-beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation10.1118/1.3077122 ↗
18. Diagnostic accuracy of cone-beam breast computed tomography: A systematic review and diagnostic meta-analysis10.1007/s00330-018-5711-9 ↗
19. Newer Technologies in Breast Cancer Imaging: Dedicated Cone-Beam Breast Computed Tomography10.1053/j.sult.2017.09.001 ↗
20. Cone-beam volume CT breast imaging: Feasibility study10.1118/1.1461843 ↗
21. Review of clinical studies and first clinical experiences with a commercially available cone-beam breast CT in Europe10.1016/j.clinimag.2016.11.011 ↗
22. Dedicated breast CT: Initial clinical experience10.1148/radiol.2463070410 ↗
23. Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging10.1088/0031-9155/49/24/003 ↗
24. Proton radiography and tomography with application to proton therapy10.1259/bjr.20150134 ↗
25. Proton imaging applications for proton therapy: State of the art
26. Review of medical radiography and tomography with proton beams10.1088/1361-6633/aa8b1d ↗
27. A review of dose calculation approaches with cone beam CT in photon and proton therapy10.1016/j.ejmp.2020.06.017 ↗
28. Bongrand, A., Koumeir, C., Villoing, D., Guertin, A., Haddad, F., Métivier, V., Poirier, F., Potiron, V., Servagent, N., and Supiot, S. (2021). A Monte Carlo Determination of Dose and Range Uncertainties for Preclinical Studies with a Proton Beam. Cancers, 13.10.3390/cancers13081889 ↗
29. Cone Beam Computed Tomography10.1016/j.cden.2018.03.002 ↗
30. Rehani, M.M., and Berry, M. (2000). Radiation doses in computed tomography. The increasing doses of radiation need to be controlled. BMJ.10.1136/bmj.320.7235.593 ↗
31. The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction: Multidisciplinary conference organized by the Society of Pediatric Radiology
32. Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest, and abdominal CT–IAEA-coordinated research project10.1148/radiol.2403050993 ↗
33. Computed tomography—An increasing source of radiation exposure10.1056/NEJMra072149 ↗
34. Computed Tomography Technology-and Dose-in the 21st Century10.1097/HP.0000000000000997 ↗
35. Ncrp Report No. 160, Ionizing Radiation Exposure of the Population of the United States, Medical Exposure—Are We Doing Less with More, and Is There A Role for Health Physicists?10.1097/01.HP.0000356672.44380.b7 ↗
36. Muhammad, N.A., Kayun, Z., Abu Hassan, H., Wong, J.H.D., Ng, K.H., and Karim, M.K.A. (2021). Evaluation of Organ Dose and Image Quality Metrics of Pediatric CT Chest-Abdomen-Pelvis (CAP) Examination: An Anthropomorphic Phantom Study. Appl. Sci., 11.10.3390/app11052047 ↗
37. Genetic susceptibility to radiogenic cancer in humans10.1097/01.HP.0000326339.06405.ea ↗
38. Avoidance of radiation injuries from medical interventional procedures10.1016/S0146-6453(00)00026-9 ↗
39. The ACR Computed Tomography Dose Index Registry: The 5 million examination update10.1016/j.jacr.2013.08.030 ↗
40. A method for describing the doses delivered by transmission X-ray computed tomography10.1118/1.594995 ↗
41. It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization. Against the proposition
42. McCollough, C.H., Leng, S., Yu, L., Cody, D.D., Boone, J.M., and McNitt-Gray, M.F. (2011). CT dose index and patient dose: They are not the same thing. Radiology.10.1148/radiol.11101800 ↗
43. Comparison of radiation doses between cone beam CT and multi detector CT: TLD measurements10.1093/rpd/ncn305 ↗
44. Council, N.R. (2006). Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2, The National Academy of Sciences.
45. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: A retrospective cohort study10.1016/S0140-6736(12)60815-0 ↗
46. Assessing cancer risks of low-dose radiation10.1038/nrc2677 ↗
47. Radiation dose from cone beam CT in a pediatric phantom: Risk estimation of cancer incidence10.2214/AJR.08.2168 ↗
48. Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations10.1118/1.2358324 ↗
49. Current state and future applications of radiological image guidance for particle therapy10.1002/mp.12744 ↗
50. Assessing the risk of second malignancies after modern radiotherapy10.1038/nrc3069 ↗
51. Estimation of the secondary cancer risk induced by diagnostic imaging radiation during proton therapy10.1088/0952-4746/31/4/007 ↗
52. Concomitant Imaging Dose and Cancer Risk in Image Guided Thoracic Radiation Therapy10.1016/j.ijrobp.2015.06.034 ↗
53. Photons—Radiobiological issues related to the risk of second malignancies10.1016/j.ejmp.2017.02.013 ↗
54. Special radiobiological features of second cancer risk after particle radiotherapy10.1016/j.ejmp.2017.05.002 ↗
55. ICRP (2000). 2000 Annual Report of the International Commission on Radiological Protection, ICRP.
56. Radiation protection principles of NCRP10.1097/00004032-200409000-00005 ↗
57. The role of Monte Carlo simulation of electron transport in radiation dosimetry10.1016/0883-2889(91)90053-4 ↗
58. Monte Carlo modelling of electron beams from medical accelerators10.1088/0031-9155/44/12/201 ↗
59. Monte Carlo simulations in radiotherapy dosimetry10.1186/s13014-018-1065-3 ↗
60. Use of Monte Carlo computation in benchmarking radiotherapy treatment planning system algorithms10.1088/0031-9155/45/7/304 ↗
61. Chow, J.C.L. (2020). Depth Dose Enhancement on Flattening-Filter-Free Photon Beam: A Monte Carlo Study in Nanoparticle-Enhanced Radiotherapy. Appl. Sci., 10.10.3390/app10207052 ↗
62. Nazemi, E., Six, N., Iuso, D., De Samber, B., Sijbers, J., and De Beenhouwer, J. (2021). Monte-Carlo-Based Estimation of the X-ray Energy Spectrum for CT Artifact Reduction. Appl. Sci., 11.10.3390/app11073145 ↗
63. Monte Carlo modelling of external radiotherapy photon beams10.1088/0031-9155/48/21/R01 ↗
64. Kawrakow, I., Mainegra Hing, E., Tessier, F., and Walters, B.R.B. (2021, April 15). The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport. Available online: https://nrc-cnrc.github.io/EGSnrc/doc/pirs701-egsnrc.pdf.
65. Briesmeister, J.F. (2000). MCNP: A General Monte Carlo N-Particle Transport Code.
66. Salvat, F., Fernandez-Varea, J.M., Acosta, E., and Sempau, J. (2001). Penelope—A Code System for Monte Carlo Simulation of Electron and Photon Transport, Nuclear Energy Agency.
67. Tapiovaara, M., Lakkisto, M., and Servomaa, A. (1997). PCXMC A PC-Based Monte Carlo Program for Calculating Patient Doses in Medical X-ray Examinations, IAEA. Technical Report.
68. GEANT4—A simulation toolkit10.1016/S0168-9002(03)01368-8 ↗
69. Geant4 developments and applications10.1109/TNS.2006.869826 ↗
70. GMC: A GPU implementation of a Monte Carlo dose calculation based on Geant410.1088/0031-9155/57/5/1217 ↗
71. Geant4-based Monte Carlo simulations on GPU for medical applications10.1088/0031-9155/58/16/5593 ↗
72. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications10.1118/1.4871617 ↗
73. A comprehensive analysis of coefficients for pendant-geometry cone-beam breast computed tomography10.1118/1.1636571 ↗
74. GATE: A simulation toolkit for PET and SPECT10.1088/0031-9155/49/19/007 ↗
75. GATE V6: A major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy10.1088/0031-9155/56/4/001 ↗
76. Dosimetry applications in GATE Monte Carlo toolkit10.1016/j.ejmp.2017.02.005 ↗
77. Townsend, D. (2011, January 23–29). In Proceedings of the 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2011), Valencia, Spain.
78. Nuclear Instruments and Methods in Physics Research A G AMOS: A framework to do G EANT 4 simulations in different physics fi elds with an user-friendly interface10.1016/j.nima.2013.09.036 ↗
79. Arce, P., Rato, P., Canadas, M., and Lagares, J.I. (2008, January 19–25). GAMOS: A Geant4-based easy and flexible framework for nuclear medicine applications. Proceedings of the 2008 IEEE Nuclear Science Symposium Conference Record, Dresden, Germany.10.1109/NSSMIC.2008.4775023 ↗
80. Calculation by GAMOS/Geant4 simulation of cellular energy distributions from alpha and lithium-7 particles created by BNCT10.1016/j.apradiso.2017.11.021 ↗
81. Internal dosimetry for TARE therapies by means of GAMOS Monte Carlo simulations10.1016/j.ejmp.2019.07.024 ↗
82. Use of short-lived positron emitters for in-beam and real-time β(+) range monitoring in proton therapy10.1016/j.ejmp.2019.12.015 ↗
83. A utility to read automatically DICOM format data for GAMOS/Geant4 simulation10.1016/j.ejmp.2016.07.549 ↗
84. Antoniadi, A.M., Du, Y., Guendouz, Y., Wei, L., Mazo, C., Becker, B.A., and Mooney, C. (2021). Current Challenges and Future Opportunities for XAI in Machine Learning-Based Clinical Decision Support Systems: A Systematic Review. Appl. Sci., 11.10.3390/app11115088 ↗
85. Longo, U.G., De Salvatore, S., Candela, V., Zollo, G., Calabrese, G., Fioravanti, S., Giannone, L., Marchetti, A., De Marinis, M.G., and Denaro, V. (2021). Augmented Reality, Virtual Reality and Artificial Intelligence in Orthopedic Surgery: A Systematic Review. Appl. Sci., 11.10.3390/app11073253 ↗
86. Lucchese, A., Bonini, C., Noviello, M., Lupo Stanghellini, M.T., Greco, R., Peccatori, J., Biella, A., Tassi, E., Beretta, V., and Ciceri, F. (2021). The Effect of Removable Orthodontic Appliances on Oral Microbiota: A Systematic Review. Appl. Sci., 11.10.3390/app11062881 ↗
87. CiteSpace II: Detecting and visualizing emerging trends and transient patterns in scientific literature10.1002/asi.20317 ↗
88. Visualizing a discipline: An author co-citation analysis of information science, 1972–1995
89. Bibliometrix: An R-tool for comprehensive science mapping analysis
90. Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector10.1002/mp.14688 ↗
91. Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach10.1016/j.ejmp.2020.01.004 ↗
92. Deterministic linear Boltzmann transport equation solver for patient-specific CT dose estimation: Comparison against a Monte Carlo benchmark for five realistic scanner configurations and patient models10.1002/mp.14494 ↗
93. GPU-accelerated Monte Carlo simulation of MV-CBCT10.1088/1361-6560/abaeba ↗
94. Postmortem Computed Tomography and Computed Tomography Angiography: Cardiothoracic Imaging Applications in Forensic Medicine10.1097/RTI.0000000000000398 ↗
95. Jia, S., Gao, H., Zhang, L., Xing, Y., and Zheng, J. (2019, January 16–21). Dental and maxillofacial cone beam computed tomography absorbed dose distribution calculation by GEANT4. Proceedings of the SPIE Medical Imaging, San Diego, CA, USA.10.1117/12.2512967 ↗
96. A fast, linear Boltzmann transport equationsolver for computed tomography dose calculation (Acuros CTD)10.1002/mp.13305 ↗
97. Comparison of Beam Characteristicsand Organ Doses for a Proton Gantry-Mounted CBCT System Modelled with MCNP6 and GATE
98. Organ doses from a proton gantry-mounted cone-beam computed tomography system characterized with MCNP6 and GATE10.1016/j.ejmp.2018.08.011 ↗
99. Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields10.1016/j.meddos.2017.08.007 ↗
100. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter—Part I: Core algorithms and validation10.1002/mp.12850 ↗