journal article·2021-10-20Open access

A Simple Approach for Counting CD4+ T Cells Based on a Combination of Magnetic Activated Cell Sorting and Automated Cell Counting Methods

Ngoc Duc Vo, Anh Thi Van Nguyen, Hoi Thi Le, Nam Hoang Nguyen, Huong Thi Thu Pham

Applied Sciences· Volume 11· Issue 21

Abstract

Frequent tests for CD4+ T cell counting are important for the treatment of patients with immune deficiency; however, the routinely used fluorescence-activated cell-sorting (FACS) gold standard is costly and the equipment is only available in central hospitals. In this study, we developed an alternative simple approach (shortly named as the MACS-Countess system) for CD4+ T cell counting by coupling magnetic activated cell sorting (MACS) to separate CD4+ T cells from blood, followed by counting the separated cells using CountessTM, an automated cell-counting system. Using the cell counting protocol, 25 µL anti-CD4 conjugated magnetic nanoparticles (NP-CD4, BD Bioscience) were optimized for separating CD4+ T cells from 50 µL of blood in PBS using a DynamagTM-2 magnet, followed by the introduction of 10 µL separated cells into a CountessTM chamber slide for automated counting of CD4+ T cells. To evaluate the reliability of the developed method, 48 blood samples with CD4+ T cell concentrations ranging from 105 to 980 cells/µL were analyzed using both MACS-Countess and FACS. Compared with FACS, MACS-Countess had a mean bias of 3.5% with a limit of agreement (LoA) ranging from −36.4% to 43.3%, which is close to the reliability of the commercial product, PIMA analyzer (Alere), reported previously (mean bias 0.2%; LoA ranging from −42% to 42%, FACS as reference). Further, the MACS-Countess system requires very simple instruments, including only a magnet and an automated cell counter, which are affordable for almost every lab located in a limited resource region.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Single-cell and spatial transcriptomics · Biosensors and Analytical Detection · Microfluidic and Bio-sensing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Enzyme and Protein Technology, VNU University of Science, Vietnam National University, 334 Nguyen Trai Street, Thanh Xuan Dist, Hanoi 100000, Vietnam

National Hospital for Tropical Diseases, No. 78 Giai Phong Street, Hanoi 100000, Vietnam

Nano and Energy Center, VNU University of Science, Vietnam National University, 334 Nguyen Trai Street, Thanh Xuan Dist, Hanoi 100000, Vietnam

Faculty of Physics, VNU University of Science, Vietnam National University, 334 Nguyen Trai Street, Thanh Xuan Dist, Hanoi 100000, Vietnam

Funding

Ministry of Science and Technology Vietnam

References (41)

Show source-provided references
1. Selective tropism of lymphadenopathy associated virus (LAV) for helper-inducer T lymphocytes10.1126/science.6328660 ↗
2. Population biology of HIV-1 infection: Viral and CD4+ T cell demographics and dynamics in lymphatic tissues10.1146/annurev.immunol.17.1.625 ↗
3. From CD4-based initiation to treating all HIV-infected adults immediately: An evidence-based meta-analysis10.3389/fimmu.2018.00212 ↗
4. Low CD4 T cell count predicts radiological progression in severe and critically ill COVID-19 patients: A case control study10.21037/jtd-20-1848 ↗
5. Immune deficiency is a risk factor for severe COVID-19 in people living with HIV10.1111/hiv.13037 ↗
6. Middle East respiratory syndrome coronavirus efficiently infects human primary T lymphocytes and activates the extrinsic and intrinsic apoptosis pathways10.1093/infdis/jiv380 ↗
7. Reduction and functional exhaustion of T cells in patients with coronavirus disease 2019 (COVID-19)10.3389/fimmu.2020.00827 ↗
8. Marked T cell activation, senescence, exhaustion and skewing towards TH17 in patients with COVID-19 pneumonia10.1038/s41467-020-17292-4 ↗
9. SARS and MERS: Recent insights into emerging coronaviruses10.1038/nrmicro.2016.81 ↗
10. Detection of surface and cytoplasmic CD4 on blood monocytes from normal and HIV-1 infected individuals10.1016/0022-1759(90)90256-U ↗
11. Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults10.1128/CDLI.7.3.336-343.2000 ↗
12. CD4 counting technologies for HIV therapy monitoring in resource-poor settings–state-of-the-art and emerging microtechnologies10.1039/c3lc50213a ↗
13. Utility of the point of care CD4 analyzer, PIMA, to enumerate CD4 counts in the field settings in India10.1186/1742-6405-9-26 ↗
14. Performance evaluation of the Alere PIMA CD4 test for monitoring HIV-infected individuals in resource-constrained settings10.1097/QAI.0b013e31822866a2 ↗
15. Pham, M.D., Agius, P.A., Romero, L., McGlynn, P., Anderson, D., Crowe, S.M., and Luchters, S. (2016). Acceptability and feasibility of point-of-care CD4 testing on HIV continuum of care in low and middle income countries: A systematic review. BMC Health Serv. Res., 16.10.1186/s12913-016-1588-y ↗
16. Larson, B., Schnippel, K., Ndibongo, B., Long, L., Fox, M.P., and Rosen, S. (2012). How to estimate the cost of point-of-care CD4 testing in program settings: An example using the Alere PimaTM analyzer in South Africa. PLoS ONE, 7.10.1371/journal.pone.0035444 ↗
17. A combined micromagnetic-microfluidic device for rapid capture and culture of rare circulating tumor cells10.1039/c2lc40072c ↗
18. Antibody conjugated magnetic iron oxide nanoparticles for cancer cell separation in fresh whole blood10.1016/j.biomaterials.2011.08.076 ↗
19. Magnetic cell separation using nano-sized bacterial magnetic particles with reconstructed magnetosome membrane10.1002/bit.21912 ↗
20. Real-time PCR method combined with immunomagnetic separation for detecting healthy and heat-injured Salmonella Typhimurium on raw duck wings10.1016/j.ijfoodmicro.2014.06.005 ↗
21. CD4 quantification based on magneto ELISA for AIDS diagnosis in low resource settings10.1016/j.talanta.2016.06.055 ↗
22. Zeb, Q., Wang, C., Shafiq, S., and Liu, L. (2019). An overview of single-cell isolation techniques. Single-Cell Omics, Academic Press.10.1016/B978-0-12-814919-5.00006-3 ↗
23. Method comparison—A different approach10.1177/000456329202900512 ↗
24. Statistical methods for assessing agreement between two methods of clinical measurement10.1016/S0140-6736(86)90837-8 ↗
25. Multiple method comparison: Statistical model using percentage similarity10.1002/cyto.b.10016 ↗
26. Evaluating new CD4 enumeration technologies for resource-constrained countries10.1038/nrmicro2000 ↗
27. Peeling, R.W., Sollis, K.A., Glover, S., Crowe, S.M., Landay, A.L., Cheng, B., Barnett, D., Denny, T.N., Spira, T.J., and Stevens, W.S. (2015). CD4 enumeration technologies: A systematic review of test performance for determining eligibility for antiretroviral therapy. PLoS ONE, 10.10.1371/journal.pone.0115019 ↗
28. Kleiveland, C.R. (2015). Peripheral blood mononuclear cells. The Impact of Food Bioactives on Health: In Vitro and Ex Vivo Models, Springer.10.1007/978-3-319-16104-4_15 ↗
29. Mwau, M., Adungo, F., Kadima, S., Njagi, E., Kirwaye, C., Abubakr, N.S., Okubi, L.A., Waihenya, M., Lusike, J., and Hungu, J. (2013). Evaluation of PIMATM® point of care technology for CD4 T cell enumeration in Kenya. PLoS ONE, 8.10.1371/journal.pone.0067612 ↗
30. Makadzange, A.T., Bogezi, C., Boyd, K., Gumbo, A., Mukura, D., Matubu, A., and Ndhlovu, C.E. (2016). Evaluation of the FACSPresto, a new point of care device for the enumeration of CD4% and absolute CD4+ T cell counts in HIV infection. PLoS ONE, 11.10.1371/journal.pone.0157546 ↗
31. Pinto, I.C., Sabidó, M., Pereira, A.B., Mello, M.B., de Melo Xavier Shimizu, A., Protti, B.L., and Benzaken, A.S. (2015). Field evaluation of a point-of-care CD4 analyzer for monitoring HIV patients in the interior of the Amazon region, Brazil. PLoS ONE, 10.10.1371/journal.pone.0121400 ↗
32. Assessment of two POC technologies for CD4 count in Morocco10.1186/s12981-020-00289-w ↗
33. Sequential CD34 cell fractionation by magnetophoresis in a magnetic dipole flow sorter10.1039/B908210G ↗
34. Rare cell capture in microfluidic devices10.1016/j.ces.2010.09.012 ↗
35. A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes10.1039/b607061m ↗
36. Kaplan, J.E., Benson, C., Holmes, K.K., Brooks, J.T., Pau, A., Masur, H., Centers for Disease Control and Prevention (CDC), National Institutes of Health, and HIV Medicine Association of the Infectious Diseases Society of America (2009). Guidelines for prevention and treatment of opportunistic infections in HIV-infected adults and adolescents: Recommendations from CDC, the National Institutes of Health, and the HIV Medicine Association of the Infectious Diseases Society of America. MMWR Recomm. Rep., Available online: https://pubmed.ncbi.nlm.nih.gov/19357635/.10.1037/e537722009-001 ↗
37. The clinical course and its correlated immune status in COVID-19 pneumonia10.1016/j.jcv.2020.104361 ↗
38. Wen, X., Jiang, D., Gao, L., Zhou, J., Xiao, J., Cheng, X., He, B., Chen, Y., Lei, P., and Tan, X. (2021). Clinical characteristics and predictive value of lower CD4+ T cell level in patients with moderate and severe COVID-19: A multicenter retrospective study. BMC Infect. Dis., 21.10.1186/s12879-020-05741-w ↗
39. Evaluation of Dynabeads and Cytospheres compared with flow cytometry to enumerate CD4+ T cells in HIV-infected Ugandans on antiretroviral therapy10.1097/QAI.0b013e31817bbc3a ↗
40. Emerging technologies for point-of-care CD4 T-lymphocyte counting10.1016/j.tibtech.2011.06.015 ↗
41. Bergeron, M., Daneau, G., Ding, T., Sitoe, N.E., Westerman, L.E., Stokx, J., Jani, I.V., Coetzee, L.M., Scott, L., and De Weggheleire, A. (2012). Performance of the PointCare NOW system for CD4 counting in HIV patients based on five independent evaluations. PLoS ONE, 7.10.1371/annotation/71a6d947-c034-4749-a33d-971284ea3408 ↗