Abstract

Infrared (IR) thermography is a tool to non-invasively assess the tear film temperature. The aim was to analyze ocular surface temperature (OST) variations in dry eye disease (DED) and control eyes under natural non-controlled blinking conditions. Imaging was performed with a thermal camera (FLIR Systems Inc.) at 30 Hz framerate in 79 participants (39 DED (62.5% women, average age 48 ± 20 years) and 40 control (46.2 % women, average age 38 ± 13 years)) using non-contact IR thermography camera. Data acquisitions were performed in natural blinking conditions for 40 s. IR images were analyzed using a custom algorithm that calculates the OST indexes: mean OST, OST at the start and at the end, minimum and maximum OST, and tear evaporation rate (TER). No significant differences were found between groups in any thermal parameter analyzed (paired comparisons t-test, p > 0.05). In conclusion, the findings of this study did not reveal significant differences between DED and control eyes under natural non-controlled blinking conditions. However, the presence of clinical signs in the control group may affect the results, highlighting the role of DED diagnosis criteria.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular Surface and Contact Lens · Glaucoma and retinal disorders · Corneal surgery and disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Optometry and Vision Department, Faculty of Optics and Optometry, University Complutense of Madrid, Avda. Arcos de Jalón, 118 28037 Madrid, Spain

Department of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, 515 SW Campus Drive, Portland, OR 97239, USA

Funding

Marie Sklodowska-Curie Actions Research Fellowship Programme · Universidad Complutense de Madrid and Banco Santander, Spain

References (47)

Show source-provided references
1. Dry eye: Diagnosis and current treatment strategies10.1007/s11882-004-0077-2 ↗
2. TFOS DEWS II Definition and Classification Report10.1016/j.jtos.2017.05.008 ↗
3. TFOS DEWS II Epidemiology Report10.1016/j.jtos.2017.05.003 ↗
4. Impact of dry eye syndrome on vision-related quality of life10.1016/j.ajo.2006.11.060 ↗
5. Impact of symptomatic dry eye on vision-related daily activities: The Singapore Malay Eye Study10.1038/eye.2010.67 ↗
6. The challenge of dry eye diagnosis10.2147/OPTH.S1496 ↗
7. TFOS DEWS II Diagnostic Methodology report10.1016/j.jtos.2017.05.001 ↗
8. (2007). Methodologies to Diagnose and Monitor Dry Eye Disease: Report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007). Ocul. Surf., 5, 108–152.10.1016/S1542-0124(12)70083-6 ↗
9. Survey of preferred tests for diagnosis of the tear film and dry eye10.1097/00003226-200007000-00016 ↗
10. Frequency of dry eye diagnostic test procedures used in various modes of ophthalmic practice10.1097/00003226-200007000-00015 ↗
11. Impact of Ocular Surface Temperature on Tear Characteristics: Current Insights10.2147/OPTO.S281601 ↗
12. Infrared methodologies for the assessment of skin temperature daily rhythm in two domestic mammalian species10.1016/j.jtherbio.2020.102677 ↗
13. Monitoring changes in body surface temperature associated with treadmill exercise in dogs by use of infrared methodology10.1016/j.jtherbio.2017.06.007 ↗
14. Thermographic ocular temperature correlated with rectal temperature in cats10.1016/j.jtherbio.2021.103104 ↗
15. Eye surface infrared thermography usefulness as a noninvasive method of measuring stress response in sheep during shearing: Correlations with serum cortisol and rectal temperature values10.1016/j.physbeh.2022.113781 ↗
16. Ocular-surface temperature modification by cataract surgery10.1016/j.jcrs.2016.04.023 ↗
17. Infrared thermographic investigation on the ocular surface temperature of normal subjects10.1088/1361-6579/ab6b48 ↗
18. Thermography in ocular inflammation10.1055/s-0041-1734381 ↗
19. TFOS DEWS II pathophysiology report10.1016/j.jtos.2017.05.011 ↗
20. Spontaneous Eye Blink Patterns in Dry Eye: Clinical Correlations10.1167/iovs.18-24690 ↗
21. Infrared thermography of the tear film in dry eye10.1038/eye.1995.149 ↗
22. The role of tear physiology in ocular surface temperature10.1038/eye.2000.156 ↗
23. Screening for dry eye with newly developed ocular surface thermographer10.1016/j.ajo.2010.10.033 ↗
24. The Relation between Physical Properties of the Anterior Eye and Ocular Surface Temperature10.1097/OPX.0b013e3180339f6e ↗
25. Relationship between Corneal Sensation, Blinking, and Tear Film Quality10.1097/OPX.0000000000000827 ↗
26. Repeatability of infrared ocular thermography in assessing healthy and dry eyes10.1016/j.clae.2016.01.010 ↗
27. Reliability and Validity of the Ocular Surface Disease Index10.1001/archopht.118.5.615 ↗
28. Determinants of corneal temperature10.1136/bjo.52.10.729 ↗
29. Morgan, P.B. (1994). Ocular thermography in health and disease. [Ph.D. Thesis, University of Manchester].
30. Alternative reference values for tear film break up time in normal and dry eye populations10.1007/978-1-4615-0717-8_157 ↗
31. Evaluation of tear evaporation from ocular surface by functional infrared thermography10.1118/1.3495540 ↗
32. Evaluation of topographical variation in ocular surface temperature by functional infrared thermography10.1016/j.infrared.2011.07.010 ↗
33. Prevalence of dry eye among the elderly10.1016/S0002-9394(14)71688-5 ↗
34. Further analysis of the human spontaneous eye blink rate by a cluster analysis-based approach to categorize individuals with ‘normal’ versus ‘frequent’ eye blink activity10.1097/01.icl.0000224359.32709.4d ↗
35. Analysis of blink rate patterns in normal subjects10.1002/mds.870120629 ↗
36. Dry eyes and video display terminals10.1056/NEJM199302253280817 ↗
37. Infrared thermography on ocular surface temperature: A review10.1016/j.infrared.2009.05.002 ↗
38. Static and Dynamic Measurement of Ocular Surface Temperature in Dry Eyes10.1155/2016/7285132 ↗
39. The core mechanism of dry eye disease is inflammation10.1097/ICL.0000000000000042 ↗
40. Corneal temperature in patients with dry eye evaluated by infrared radiation thermometry10.1136/bjo.80.1.29 ↗
41. Use of high-speed, high-resolution thermography to evaluate the tear film layer10.1016/S0002-9394(14)71689-7 ↗
42. Tear evaporation rates: What does the literature tell us?10.1016/j.clae.2017.12.003 ↗
43. Ocular Water Evaporation and the Dry Eye: A New Measuring Device10.1097/00003226-199307000-00010 ↗
44. The interblink interval in normal and dry eye subjects10.2147/OPTH.S39104 ↗
45. Quantitative videographic analysis of blinking in normal subjects and patients with dry eye10.1001/archopht.1996.01100130707012 ↗
46. Temperatures of the Ocular Surface, Lid, and Periorbital Regions of Sjögren’s, Evaporative, and Aqueous-Deficient Dry Eyes Relative to Normals10.1016/j.jtos.2015.09.001 ↗
47. Correlations among ocular surface temperature difference value, the tear meniscus height, Schirmer’s test and fluorescein tear film break up time10.1136/bjophthalmol-2014-305183 ↗