Agreement of the Discrepancy Index Obtained Using Digital and Manual Techniques—A Comparative Study
Source abstract
Abstract
The discrepancy index evaluates the complexity of the initial orthodontic diagnosis. The objective is to compare whether there is a difference in the final discrepancy index score of the American Board of Orthodontics (ABO) when obtained using digital and manual techniques. Fifty-six initial orthodontic records in a digital and physical format were included (28 each) in 2022 at the Center for Research and Advanced Studies in Dentistry. For the digital measurements, iTero and TRIOS 3 intraoral scanners were used, along with Insignia software and cephalometric tracing with Dolphin Imaging software. Manual measurements were obtained in dental casts using the ruler indicated for the previously mentioned discrepancy index, in addition to conventional cephalometric tracing. Student’s t-test did not show statistically significant differences between the digital and manual techniques, with final discrepancy index scores of 24.61 (13.34) and 24.86 (14.14), respectively (p = 0.769). Cohen’s kappa index showed very good agreement between both categorical measurements (kappa value = 1.00, p = 0.001). The Bland–Altman method demonstrated a good agreement between continuous measurements obtained by both techniques with a bias of 0.2500 (superior limit of agreement =9.0092988, inferior limit of agreement = −8.5092988). Excellent agreement was observed in obtaining the discrepancy index through digital technique (Intraoral scanning and digital records) and manual technique (conventional records).
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Radiography and Imaging · Digital Imaging in Medicine · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Center for Research and Advanced Studies in Dentistry, School of Dentistry, Autonomous University of Mexico State, 50130 Toluca, Estado de México, Mexico
References (44)
Show source-provided references
1. Iatrogenics in Orthodontics and Its Challenges10.1590/2177-6709.21.5.114-125.sar ↗
2. Evaluation of Commonly Used Occlusal Indices in Determining Orthodontic Treatment Need
3. An Overview of the American Board of Orthodontics Certification Process10.4103/apos.apos_2_18 ↗
4. Diagnostic Accuracy and Measurement Sensitivity of Digital Models for Orthodontic Purposes: A Systematic Review10.1016/j.ajodo.2015.06.029 ↗
5. Genauigkeit von Stereolitographisch Gedruckten Digitalen Modellen Im Vergleich Zu Gipsmodellen10.1007/s00056-017-0093-1 ↗
6. Accuracy and Practicality of Intraoral Scanner in Dentistry: A Literature Review10.1016/j.jpor.2019.07.010 ↗
7. Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral Scanners in Dentistry: A Review of the Current Literature. BMC Oral Health, 17.10.1186/s12903-017-0442-x ↗
8. Accuracy of Digital Technologies for the Scanning of Facial, Skeletal, and Intraoral Tissues: A Systematic Review10.1016/j.prosdent.2018.01.015 ↗
9. Park, S.H., Byun, S.H., Oh, S.H., Lee, H.L., Kim, J.W., Yang, B.E., and Park, I.Y. (2020). Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients. J. Clin. Med., 9.10.3390/jcm9092728 ↗
10. Reproducibility of an Intraoral Scanner: A Comparison between In-Vivo and Ex-Vivo Scans10.1016/j.ajodo.2017.09.022 ↗
11. Effectiveness and Efficiency of a CAD/CAM Orthodontic Bracket System10.1016/j.ajodo.2015.07.029 ↗
12. Discrepancy Index Relative to Age, Sex, and the Probability of Completing Treatment by One Resident in a 2-Year Graduate Orthodontics Program10.1016/j.ajodo.2010.09.003 ↗
13. Outcomes of Orthodontic Treatment Performed by Individual Orthodontists vs 2 Orthodontists Collaborating on Treatment10.1016/j.ajodo.2019.07.015 ↗
14. The ABO Discrepancy Index: A Measure of Case Complexity10.1016/j.ajodo.2004.01.005 ↗
15. American Board of Orthodontics (2016). The ABO Discrepancy Index (DI) A Measure of Case Complexity. J. World Fed. Orthodont., 11, 270–278.
16. Relationship between the Dental Aesthetic Index and Discrepancy Index10.1177/1465312520930729 ↗
17. Validity of the American Board of Orthodontics Discrepancy Index and the Peer Assessment Rating Index for Comprehensive Evaluation of Malocclusion Severity10.1111/ocr.12195 ↗
18. Orthodontic Treatment; orthodontic treatment need at Faisalabad Medical University and de’Montmorency College of Dentistry
19. The Relationship between the ABO Discrepancy Index and Treatment Duration in a Graduate Orthodontic Clinic10.2319/062210-341.1 ↗
20. Correlation between Adolescent Orthodontic Quality of Life and ABO Discrepancy Index in an Orthodontic Treatment-Seeking Population: A Cross-Sectional Study10.1177/14653125211007498 ↗
21. Treatment Complexity Index for Assessing the Relationship of Treatment Duration and Outcomes in a Graduate Orthodontics Clinic10.1016/j.ajodo.2007.08.012 ↗
22. Clinical Outcomes of Lingual Fully Customized vs Labial Straight Wire Systems: Assessment Based on American Board of Orthodontics Criteria10.1007/s00056-020-00248-0 ↗
23. A Beginning Guide for Dental Photography: A Simplified Introduction for Esthetic Dentistry10.1016/j.cden.2020.07.002 ↗
24. How Is Orthodontic Treatment Need Associated with Perceived Esthetic Impact of Malocclusion in Adolescents?10.1016/j.ajodo.2019.09.009 ↗
25. Comparación de Los Índices ICON y El Componente Estético Del IOTN Para Determinar La Necesidad de Tratamiento Ortodóncico10.1016/j.rmo.2017.03.020 ↗
26. American Board of Orthodontics (ABO) Discrepancy Index and Peer Assessment Rating (PAR) Index with Models versus Photographs
27. Artificial Intelligence in Orthodontics: Evaluation of a Fully Automated Cephalometric Analysis Using a Customized Convolutional Neural Network10.1007/s00056-019-00203-8 ↗
28. Assessing the Reliability of Digitalized Cephalometric Analysis in Comparison with Manual Cephalometric Analysis
29. Reliability and Intra-Examiner Agreement of Orthodontic Model Analysis with a Digital Caliper on Plaster and Printed Dental Models10.1007/s00784-018-2772-8 ↗
30. Validity and Reliability of Intraoral Scanners Compared to Conventional Gypsum Models Measurements: A Systematic Review10.1093/ejo/cjw033 ↗
31. Moving towards Precision Orthodontics: An Evolving Paradigm Shift in the Planning and Delivery of Customized Orthodontic Therapy10.1111/ocr.12171 ↗
32. The Reliability and Validity of Measurements of Human Dental Casts Made by an Intra-Oral 3D Scanner, with Conventional Hand-Held Digital Callipers as the Comparison Measure10.1016/j.forsciint.2017.07.009 ↗
33. Efficiency and Accuracy of Three-Dimensional Models Versus Dental Casts: A Clinical Study10.5152/TurkJOrthod.2019.19034 ↗
34. Evaluation of the Accuracy of Digital and 3D-Printed Casts Compared with Conventional Stone Casts10.1016/j.prosdent.2020.08.039 ↗
35. Jedliński, M., Mazur, M., Grocholewicz, K., and Janiszewska-Olszowska, J. (2021). 3D Scanners in Orthodontics-Current Knowledge and Future Perspectives-A Systematic Review. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18031121 ↗
36. Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva10.1155/2020/2920804 ↗
37. Trueness and Precision of Intraoral Scanners in the Maxillary Dental Arch: An In Vivo Analysis10.1038/s41598-020-58075-7 ↗
38. Reliability and Validity of Intraoral and Extraoral Scanners10.1186/s40510-015-0108-7 ↗
39. Comparison of Digital Intraoral Scanners and Alginate Impressions: Time and Patient Satisfaction10.1016/j.ajodo.2017.08.017 ↗
40. Agreement of Treatment Recommendations Based on Digital vs Plaster Dental Models10.1016/j.ajodo.2018.03.018 ↗
41. Comparison of Dental Measurements between Conventional Plaster Models, Digital Models Obtained by Impression Scanning and Plaster Model Scanning10.1016/j.ortho.2019.01.014 ↗
42. Accuracy of Digital Models Generated by Conventional Impression/Plaster-Model Methods and Intraoral Scanning10.4012/dmj.2017-208 ↗
43. Comparison of Automated Grading of Digital Orthodontic Models and Hand Grading of 3-Dimensionally Printed Models10.1016/j.ajodo.2018.11.011 ↗
44. Accuracy of Digital American Board of Orthodontics Discrepancy Index Measurements10.1016/j.ajodo.2015.02.027 ↗