journal article·2023-04-08Open access

The Seismic Resistance Analysis of Frame Structures and Wall Structures Using Ferrocement and Expanded Metal

Yossakorn Chonratana, Vuttichai Chatpattananan

Applied Sciences· Volume 13· Issue 8

Abstract

This article presents a study of the use of ferrocement and expanded metal in the columns, beams, and walls of a reinforced concrete building structure to increase its seismic resistance. This study focused on a concrete building with three stories, located in Thailand. In the design of the reinforcement structure, a calculation and analysis of seismic resistance were conducted in a comparison of the original concrete building structure with the reinforced concrete building structure using the nonlinear static force method (pushover analysis method). The results showed that the seismic resistance of the reinforced concrete building structure was higher than the design value (DPT), with different seismic resistance values for the reinforced frames, columns, and walls of approximately 14%, 81%, and 19%. In particular, it had increased stiffness values for the frames, columns, and walls and increased ductility values for the walls. Moreover, the seismic resistance values originating from the reinforcement were significantly higher than those of the concrete building structure. Therefore, reinforcement should be applied to all concrete building structures with the implementation of the damage index, ensuring that it is reduced to the allowable level.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Seismic Performance and Analysis · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand

References (15)

Show source-provided references
1. Performance of structures in the MW 6.1 mae lao earthquake in Thailand on May 5, 2014, and implications for future construction10.1080/13632469.2015.1051636 ↗
2. Seismic shear strengthening of R/C columns with ferrocement jacket10.1016/j.cemconcomp.2005.03.011 ↗
3. Seismic capacity of masonry infilled RC frame strengthening with expanded metal ferrocement10.1016/j.engstruct.2017.12.034 ↗
4. Seismic Strengthening of RC Frame and Brick Infill Panel using Ferrocement and Expanded Metal10.4186/ej.2020.24.3.45 ↗
5. Influence of interfacial characteristics on the shear bond behavior between concrete and ferrocement10.1016/j.conbuildmat.2018.05.084 ↗
6. Seismic shear strengthening of reinforced concrete short columns using ferrocement with expanded metal10.4186/ej.2019.23.6.175 ↗
7. Performance evaluation of structures with reinforced concrete columns retrofitted with steel jacketing10.1016/j.jobe.2020.101510 ↗
8. Seismic analysis of RC frame with brick infill panel strengthened by steel cage and expanded metal10.4186/ej.2021.25.4.29 ↗
9. Development of Lightweight Concrete Interlocking Block Panel with Water Treatment Sludge and Expanded Metal Ferrocement10.4186/ej.2021.25.1.81 ↗
10. Inelastic design of infilled frames
11. (2018). Building Design Standards for Seismic Resistance. Standard No. DPT. 1301/1302-61.
12. Carr, A.J. (2006). RUAUMOKO Computer Program, University of Canterbury.
13. Saiidi, M., and Sozen, M.A. (1979). Simple and Complex Models for Nonlinear Seismic Response of Reinforced Concrete Structures, Department of Civil Engineering, University of Illinois. Report UILU–ENG-79-2031.
14. Stewart, W.G. (1987). The Seismic Design of Plywood Sheathed Shear Walls. [Ph.D. Thesis, Department of Civil Engineering, University of Canterbury].
15. Mechanistic seismic damage model for reinforced concrete10.1061/(ASCE)0733-9445(1985)111:4(722) ↗