journal article·2022-11-14Open access

In Silico Evaluation of a Physiological Controller for a Rotary Blood Pump Based on a Sensorless Estimator

Mohsen Bakouri, Ahmad Alassaf, Khaled Alshareef, Ibrahim AlMohimeed, Abdulrahman Alqahtani, Mohamed Abdelkader Aboamer, Khalid A. Alonazi, Yousef Alharbi

Applied Sciences· Volume 12· Issue 22

Abstract

In this study, we present a sensorless, robust, and physiological tracking control method to drive the operational speed of implantable rotary blood pumps (IRBPs) for patients with heart failure (HF). The method used sensorless measurements of the pump flow to track the desired reference flow (Qr). A dynamical estimator model was used to estimate the average pump flow (Q^est) based on pulse-width modulation (PWM) signals. A proportional-integral (PI) controller integrated with a fuzzy logic control (FLC) system was developed to automatically adapt the pump flow. The Qr was modeled as a constant and trigonometric function using an elastance function (E(t)) to achieve a variation in the metabolic demand. The proposed method was evaluated in silico using a lumped parameter model of the cardiovascular system (CVS) under rest and exercise scenarios. The findings demonstrated that the proposed control system efficiently updated the pump speed of the IRBP to avoid suction or overperfusion. In all scenarios, the numerical results for the left atrium pressure (Pla), aortic pressure (Pao), and left ventricle pressure (Plv) were clinically accepted. The Q^est accurately tracked the Qr within an error of 0.25 L/min.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Fuel Cells and Related Materials · Cardiovascular Function and Risk Factors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Medical Equipment Technology, College of Applied Medical Science, Majmaah University, Al-Majmaah 11952, Saudi Arabia

Department of Physics, College of Arts, Fezzan University, Traghen City 71340, Libya

Department of Biomedical Technology, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia

Health Services, Ministry of Defense, Riyadh 12426, Saudi Arabia

Funding

Research and Innovation, Ministry of Education, Saudi Arabia

References (32)

Show source-provided references
1. Wang, Y., Shen, P., Zheng, M., Fu, P., Liu, L., Wang, J., and Yuan, L. (2019). Influence of Impeller Speed Patterns on Hemodynamic Characteristics and Hemolysis of the Blood Pump. Appl. Sci., 9.10.3390/app9214689 ↗
2. Recent advances in the application of computational fluid dynamics in the development of rotary blood pumps10.1016/j.medntd.2022.100177 ↗
3. Bakouri, M. (2019). Physiological Control Law for Rotary Blood Pumps with Full-State Feedback Method. Appl. Sci., 9.10.3390/app9214593 ↗
4. Jing, T., Xin, T., Wang, F., Zhang, Z., and Zhou, L. (2022). Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback. Micromachines, 13.10.3390/mi13030358 ↗
5. Non-parametric dynamical estimation of blood flow rate, pressure difference and viscosity for a miniaturized blood pump10.1177/03913988211006720 ↗
6. Weiss, W.; Rosenberg, G. Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop10.1097/MAT.0000000000001619 ↗
7. Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model10.1111/aor.13795 ↗
8. Extremum-seeking control of left ventricular assist device to maximize the cardiac output and prevent suction10.1016/j.chaos.2021.111013 ↗
9. Liang, L., Qin, K., El-Baz, A.S., Roussel, T.J., Sethu, P., Giridharan, G.A., and Wang, Y. (2021). A Flow Sensor-Based Suction-Index Control Strategy for Rotary Left Ventricular Assist Devices. Sensors, 21.10.3390/s21206890 ↗
10. Yun, Z., Li, K., Jiang, H., and Tang, X. (2022). A Composite Flexible Sensor for Direct Ventricular Assist Device. Sensors, 22.10.3390/s22072607 ↗
11. Adaptive sensorless control of LVAD using deep convolutional neural network10.1016/j.healun.2021.01.507 ↗
12. Bakouri, M., Alassaf, A., Alshareef, K., Abdelsalam, S., Ismail, H.F., Ganoun, A., and Alomari, A.-H. (2022). An Optimal H-Infinity Controller for Left Ventricular Assist Devices Based on a Starling-like Controller: A Simulation Study. Mathematics, 10.10.3390/math10050731 ↗
13. A physiological control system for ECG-synchronized pulsatile pediatric ventricular assist devices10.1016/j.bspc.2019.101752 ↗
14. Modelling and control of a failing heart managed by a left ventricular assist device10.1016/j.bbe.2020.01.014 ↗
15. Pulse-Pressure–Enhancing Controller for Better Physiologic Perfusion of Rotary Blood Pumps Based on Speed Modulation10.1097/MAT.0000000000000059 ↗
16. A sensorless approach to control of a turbodynamic left ventricular assist system10.1109/87.918900 ↗
17. Sensorless physiologic control, suction prevention, and flow balancing algorithm for rotary biventricular assist devices10.1109/TCST.2017.2773518 ↗
18. Parameter-Optimized Model of Cardiovascular–Rotary Blood Pump Interactions10.1109/TBME.2009.2031629 ↗
19. Numerical optimization studies of cardiovascular–rotary blood pump interaction10.1111/j.1525-1594.2012.01449.x ↗
20. Nonlinear modelling and control of left ventricular assist device10.1049/el.2014.4330 ↗
21. A Sliding Mode-Based Starling-Like Controller for Implantable Rotary Blood Pumps10.1111/aor.12223 ↗
22. Nise, N.S. (2020). Control Systems Engineering, John Wiley & Sons.
23. Jayetileke, H.R., de Mel, W.R., and Mukhopadhyay, S.C. (2022). Real-Time Metaheuristic Algorithm for Dynamic Fuzzification, De-Fuzzification and Fuzzy Reasoning Processes. Appl. Sci., 12.10.3390/app12168242 ↗
24. A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements10.1111/j.1525-1594.2011.01268.x ↗
25. Physiologic outcome of varying speed rotary blood pump support algorithms: A review study. Australas10.1007/s13246-015-0405-y ↗
26. A novel control method for rotary blood pumps as left ventricular assist device utilizing aortic valve state detection
27. A physiological control system for an implantable heart pump that accommodates for interpatient and intrapatient variations10.1109/TBME.2019.2932233 ↗
28. Developments in control systems for rotary left ventricular assist devices for heart failure patients: A review10.1088/0967-3334/34/1/R1 ↗
29. Peng, J., Lu, A., and Wang, Y. (2018, January 19–21). Modeling of a New Sensorless Suction Detection System for the Rotary Left Ventricular Assist Device. Proceedings of the 9th International Conference in Information Technology Medicine Education ITME 2018, Hangzhou, China.10.1109/ITME.2018.00062 ↗
30. Son, J., Du, D., and Du, Y. (2019, January 9–13). Feedback control of rotary blood pump for preventing left ventricular suction. Proceedings of the America Control Conference 2019, Philadelphia, PA, USA.10.23919/ACC.2019.8814818 ↗
31. Bakouri, M., Alassaf, A., Alshareef, K., Smida, A., AlMohimeed, I., Alqahtani, A., Aboamer, M.A., and Alharbi, Y. (2022). A Feasible Method to Control Left Ventricular Assist Devices for Heart Failure Patients: A Numerical Study. Mathematics, 10.10.3390/math10132251 ↗
32. Theoretical foundations of a Starling-like controller for rotary blood pumps10.1111/j.1525-1594.2012.01457.x ↗