journal article·2022-11-02Open access

The Energy Consumption and Robust Case Torque Control of a Rehabilitation Hip Exoskeleton

Rabé Andersson, Niclas Björsell

Applied Sciences· Volume 12· Issue 21

Abstract

Gait disorders, muscle weakness, spinal cord injuries (SCIs) and other work-related disorders have increased the need for rehabilitation exoskeletons—specifically, for the hip because a huge percentage of mechanical power comes from the hip joint. However, realising a lightweight rehabilitation hip exoskeleton for mobility and at-home use with reliable control is challenging. The devices developed are restricted by a joint actuator and energy source design and tend to have various uncertainties. Thus, this study tested the robustness of four optimal controller cases in a simulation-based environment. We sought to determine whether the most robust optimal controller consumed less energy and demonstrated better performance in tracking the desired signal. The robustness of the optimal cases was tested with the hip torque signals of healthy subjects. The number of sit-to-stand (STS) instances and the walking distance at various speeds were calculated. The results showed that the most robust case controller was more energy efficient for STS, but not for walking activity. Furthermore, this study provides compelling evidence that various optimal controllers have different degrees of robustness and effects on energy consumption.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies · Stroke Rehabilitation and Recovery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical Engineering, Mathematics and Science, University of Gävle, 801 76 Gävle, Sweden

References (62)

Show source-provided references
1. Andersson, R., Björsell, N., and Isaksson, M. (2021, January 26–27). Robots Are a Promising Investment to Fight Pandemics. Proceedings of the 8th International Conference on Signal Processing and Integrated Networks (SPIN), Noida, India.10.1109/SPIN52536.2021.9566116 ↗
2. Buongiorno, D. (2017). Advanced Control Strategies ForNatural Human-Exoskeleton Interaction. [Ph.D. Dissertation, Sant’ Anna School of Advanced Studies].
3. Pons, J.L. (2008). Wearable Robots: Biomechatronic Exoskeletons, John Wiley & Sons.10.1002/9780470987667 ↗
4. Intention to Use Exoskeletons in Geriatric Care Work: Need for Ergonomic and Social Design
5. Cerebral Palsy in Children: A Clinical Overview10.21037/tp.2020.01.01 ↗
6. Volpicelli, G.M. (2022, July 10). Review: Sportsmate 5 Fitness Exoskeleton|WIRED. WIRED.com. Available online: https://www.wired.com/review/sportsmate-5-fitness-exoskeleton/.
7. Yuzbasioglu, N. (2022, July 10). Elderly to Make Up 22% of World Population by 2050. Available online: https://www.aa.com.tr/en/life/elderly-to-make-up-22-of-world-population-by-2050/2379462.
8. Andersson, R., and Björsell, N. The MATLAB Simulation and the Linear Quadratic Regulator Torque Control of a Series Elastic Actuator for a Rehabilitation Hip Exoskeleton. IRCE, 2022. in press.10.1109/IRCE55557.2022.9963074 ↗
9. Design and Control of an Exoskeleton Robot: A Matlab Simscape Application
10. Recent Developments and Challenges of Lower Extremity Exoskeletons
11. Hsu, S.H., Changcheng, C., Lee, H.J., and Chen, C.T. (2021). Design and Implementation of a Robotic Hip Exoskeleton for Gait Rehabilitation. Actuators, 10.10.3390/act10090212 ↗
12. Robotic Assisted Upper Limb Training Post Stroke: A Randomized Control Trial Using Combinatory Approach Toward Reducing Workforce Demands10.3389/fneur.2021.622014 ↗
13. Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art10.1109/JSYST.2014.2351491 ↗
14. Analysis of the Human Interaction with a Wearable Lower-Limb Exoskeleton
15. Development of a Wearable Exoskeleton Rehabilitation System Based on Hybrid Control Mode10.1177/1729881416664847 ↗
16. Modeling and Control of a Novel Design of Series Elastic Actuator for Upper Limb Rehabilitation10.18280/mmep.090111 ↗
17. Human-Robot Interaction Control of Rehabilitation Robots with Series Elastic Actuators10.1109/TRO.2015.2457314 ↗
18. Modeling and Control of a Curved Pneumatic Muscle Actuator for Wearable Elbow Exoskeleton10.1016/j.mechatronics.2008.02.006 ↗
19. Human-in-the-Loop Optimization of Hip Assistance with a Soft Exosuit during Walking10.1126/scirobotics.aar5438 ↗
20. The Effect of Hip Assistance Levels on Human Energetic Cost Using Robotic Hip Exoskeletons10.1109/LRA.2019.2890896 ↗
21. Tu, X., Li, M., Liu, M., Si, J., and Huang, H. (June, January 30). A Data-Driven Reinforcement Learning Solution Framework for Optimal and Adaptive Personalization of a Hip Exoskeleton. Proceedings of the 2021 IEEE International Conference on Robotics and Automation (ICRA), Xi’an, China.10.1109/ICRA48506.2021.9562062 ↗
22. Imposing Healthy Hip Motion Pattern and Range by Exoskeleton Control for Individualized Assistance10.1109/LRA.2022.3196105 ↗
23. He, H., and Kiguchi, K. (2007, January 8–11). A Study on EMG-Based Control of Exoskeleton Robots for Human Lower-Limb Motion Assist. Proceedings of the 2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine, Tokyo, Japan.10.1109/ITAB.2007.4407405 ↗
24. A Robust Control Scheme Based on Sliding Mode Observer to Drive a Knee-Exoskeleton10.1002/asjc.1950 ↗
25. Comparing Optimized Exoskeleton Assistance of the Hip, Knee and Ankle in Single and Multi-Joint Configurations10.1017/wtc.2021.14 ↗
26. Mahdavian, M., Arzanpour, S., and Park, E.J. (2007, January 8–11). Motion Generation of a Wearable Hip Exoskeleton Robot Using Machine Learning-Based Estimation of Ground Reaction Forces and Moments. Proceedings of the 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, Tokyo, Japan.10.1109/AIM.2019.8868759 ↗
27. Ajayi, M.O. (2016). Modelling and Control of Actuated Lower Limb Exoskeletons a Mathematical Application Using Central Pattern Generators and Nonlinear Feedback Control Techniques. [Ph.D. Dissertation, Tshwane University of Technology].
28. Benchmarking Torque Control Strategies for a Torsion-Based Series Elastic Actuator10.1109/MRA.2021.3124154 ↗
29. Pratt, G.A., Williamson, M.M., Dillworth, P., Pratt, J., and Wright, A. (2005). Stiffness Isn’t Everything. Experimental Robotics IV, Springer.
30. A Novel Design of Serial Variable Stiffness Actuator Based on an Archimedean Spiral Relocation Mechanism10.1109/TMECH.2018.2854742 ↗
31. Series Elastic Actuators
32. Compliant Actuator Designs: Review of Actuators with Passive Adjustable Compliance/Controllable Stiffness for Robotic Applications10.1109/MRA.2009.933629 ↗
33. A Tutorial Survey and Comparison of Impedance Control on Robotic Manipulation10.1017/S0263574718001339 ↗
34. Modeling and Control of a Cable-Driven Rotary Series Elastic Actuator for an Upper Limb Rehabilitation Robot10.3389/fnbot.2020.00013 ↗
35. Chen, J., Fan, Y., Sheng, M., and Zhu, M. (2019, January 3–5). Optimized Control for Exoskeleton for Lower Limb Rehabilitation with Uncertainty. Proceedings of the 2019 Chinese Control And Decision Conference, Nanchang, China.10.1109/CCDC.2019.8833418 ↗
36. Design and Development of a Durable Series Elastic Actuator with an Optimized Spring Topology10.1177/09544062211020337 ↗
37. Human-Exoskeleton Control Simulation, Kinetic and Kinematic Modeling and Parameters Extraction10.1016/j.mex.2019.08.014 ↗
38. Problematic Secondary Health Conditions among Adults with Spinal Cord Injury and Its Impact on Social Participation and Daily Life10.1080/10790268.2015.1123845 ↗
39. The Crucial Changes of Sit-to-Stand Phases in Subacute Stroke Survivors Identified by Movement Decomposition Analysis10.3389/fneur.2018.00185 ↗
40. Sit-to-Stand and Stand-to-Sit Assistance for Paraplegic Patients with CUHK-EXO Exoskeleton10.1017/S0263574717000546 ↗
41. Joint Torques during Sit-to-Stand in Healthy Subjects and People with Parkinson’s Disease10.1016/S0268-0033(02)00191-2 ↗
42. Grimmer, M., and Seyfarth, A. (2014). Mimicking Human-Like Leg Function in Prosthetic Limbs. Neuro-Robotics, Springer.10.1007/978-94-017-8932-5_5 ↗
43. Speed Variation and Resultant Joint Torques during Sit-to-Stand10.1016/0003-9993(91)90004-3 ↗
44. Grimmer, M. (2015). Powered Lower Limb Prostheses. [Ph.D. Thesis, Technische Universität].
45. Yildirim, M.C., Kansizoglu, A.T., Sendur, P., Coruk, S., and Ugurlu, B. (2018, January 21–25). Development of a High Torque-to-Mass Ratio Series Elastic Actuator. Proceedings of the 2018 International Conference on Robotics and Automation (ICRA), Brisbane, Australia.
46. Ellis, G., and George, H. (2002). Observers in Control Systems: A Practical Guide, Academic Press.
47. Duriez, T., Brunton, S.L., and Noack, B.R. (2013). Machine Learning Dynamics and Taming Nonlinear Control—Turbulence, Springer International Publishing. Fluid Mechanics and Its Applications.
48. Multivariable Feedback Control—Analisys and Design
49. Ogata, K. (2017). Modern Control Engineering, Pearson. [5th ed.].
50. Doyle, J., Francis, B., and Tannenbaum, A. (1998). Feedback Control Theory, Macmillan Publishing Co.
51. Åström, K.J. (2000). Model Uncertainty and Robust Control, Valencia Polytechnic University.
52. Palomba, I., Wehrle, E., Carabin, G., and Vidoni, R. (2020). Minimization of the Energy Consumption in Industrial Robots through Regenerative Drives and Optimally Designed Compliant Elements. Appl. Sci., 10.10.3390/app10217475 ↗
53. Van Kammen, K., Boonstra, A., Reinders-Messelink, H., and Den Otter, R. (2014). The Combined Effects of Body Weight Support and Gait Speed on Gait Related Muscle Activity: A Comparison between Walking in the Lokomat Exoskeleton and Regular Treadmill Walking. PLoS ONE, 9.10.1371/journal.pone.0107323 ↗
54. Adjustments to Zatsiorsky-Seluyanov’s Segment Inertia Parameters10.1016/0021-9290(95)00178-6 ↗
55. Lee, C., Kwak, S., Kwak, J., and Oh, S. (2017). Generalization of Series Elastic Actuator Configurations and Dynamic Behavior Comparison. Actuators, 6.10.3390/act6030026 ↗
56. The Compliant Joint Toolbox for MATLAB: An Introduction with Examples10.1109/MRA.2019.2896360 ↗
57. High-Precision Robust Force Control of a Series Elastic Actuator10.1109/TMECH.2016.2614503 ↗
58. Design and Simulation of PID Controller for Lower Limb Exoskeleton Robot10.1063/1.5046300 ↗
59. An Introduction to Disk Margins [Lecture Notes]10.1109/MCS.2020.3005277 ↗
60. Glad, T., and Ljung, L. (2000). Control Theory: Multivariable and Nonlinear Methods, Taylor & Francis.
61. Multiloop PI/PID Control System Improvement via Adjusting the Dominant Pole or the Peak Amplitude Ratio10.1016/j.ces.2005.08.044 ↗
62. Zero-Torque Control of an Exoskeleton Joint Actuator Using a Disturbance Observer10.1063/1.5121929 ↗