journal article·2019-03-27Open access

One-Year Results of a Randomized Controlled Clinical Trial of Immediately Loaded Short Implants Placed in the Lower Posterior Single Molar Using a Complete Digital Workflow

Yeon-Wha Baek, Young-Jun Lim, Jungwon Lee, Ki-Tae Koo, Myung-Joo Kim, Ho-Beom Kwon

Applied Sciences· Volume 9· Issue 7

Abstract

The purpose of this randomized clinical trial is to evaluate immediately loaded single implants with varying lengths in the posterior mandible using a fully digital, model-free prosthetic-driven implant planning pathway, and to compare clinical and radiological outcomes of short and long implants. The 52 patients with the single tooth missing in the posterior molar regions of the mandible were randomly assigned to the control (CMI IS-III active® long implant; 5.0 × 10 mm) and experimental (CMI IS-III active® short implant; 5.5 × 6.6, 7.3, 8.5 mm) groups. For each patient, a single implant was placed using the computer aided surgical template and all prostheses were fabricated by means of computer-aided design/computer-aided manufacturing (CAD/CAM) system on the virtual model. The patients received provisional and definitive monolithic zirconia prostheses at 1 week and 12 weeks after implant surgery, respectively. The implant stability quotient (ISQ) measurements and periapical radiographs were taken and peri-implant parameters were evaluated at 1, 3, 4, 8, 12, 24, 36, and 48 weeks after surgery. Nineteen long implants and 27 short implants were finally used for the statistical analysis. There was no significant difference between the groups in terms of insertion torque, ISQ values (except 3 weeks), marginal bone loss, and peri-implant soft tissue parameters (p > 0.05). Both groups exhibited no stability dip during the early phase of healing. The average marginal bone loss from the baseline of implant placement for the control and experimental groups was −0.07 and 0.03 mm after 12 weeks and 0.06 and 0.05 mm after 48 weeks. All of the soft tissue parameters were within normal limits. Within the limits of the short term follow up, immediate loading of short single implants can be considered as one of predictable treatment modality in mandible with reduced bone height when primary stability can be achieved.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, Korea

Department of Periodontics, One-Stop Specialty Center, Seoul National University, Dental Hospital, Seoul 03080, Korea

Department of Periodontology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, Korea

Funding

a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea .

References (59)

Show source-provided references
1. Complete digital workflow for the production of implant-supported single-unit monolithic crowns10.1111/clr.12270 ↗
2. Digital implant dentistry—A workflow in five steps
3. Digital approach to planning computer-guided surgery and immediate provisionalization in a partially edentulous patient10.1016/j.prosdent.2015.11.023 ↗
4. Flapless surgery and its effect on dental implant outcomes
5. Computer-guided implant therapy and soft- and hard-tissue aspects. The Third EAO Consensus Conference 201210.1111/j.1600-0501.2012.02553.x ↗
6. State of the art of short dental implants: A systematic review of the literature10.1111/j.1708-8208.2010.00303.x ↗
7. Advances in bone augmentation to enable dental implant placement: Consensus Report of the Sixth European Workshop on Periodontology10.1111/j.1600-051X.2008.01268.x ↗
8. Vertical ridge augmentation using guided bone regeneration (GBR) in three clinical scenarios prior to implant placement: A retrospective study of 35 patients 12 to 72 months after loading
9. Treatment of the atrophic edentulous maxilla: Short implants versus bone augmentation for placing longer implants. Five-month post-loading results of a pilot randomised controlled trial
10. Delayed expansion of the atrophic mandible by ultrasonic surgery: A clinical and histologic case series10.11607/jomi.2753 ↗
11. Branemark system implants in the posterior maxilla: Clinical study of 660 implants followed for 5 to 12 years
12. Biologic outcome of implant-supported restorations in the treatment of partial edentulism: Part 1: A longitudinal clinical evaluation10.1034/j.1600-0501.2002.130406.x ↗
13. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures
14. Short (8-mm) locking-taper implants supporting single crowns in posterior region: A prospective clinical study with 1-to 10-years of follow-up10.1111/clr.12181 ↗
15. Use of short implants (6 mm) in a single-tooth replacement: A 5-year follow-up prospective randomized controlled multicenter clinical study10.1111/clr.12564 ↗
16. A 3-year post-loading report of a randomised controlled trial on the rehabilitation of posterior atrophic mandibles: Short implants or longer implants in vertically augmented bone?
17. A systematic review of the prognosis of short (<10 mm) dental implants placed in the partially edentulous patient10.1111/j.1600-051X.2011.01736.x ↗
18. Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants
19. Esposito, M., Grusovin, M.G., Maghaireh, H., and Worthington, H.V. (2013). Interventions for replacing missing teeth: Different times for loading dental implants. Cochrane Database Syst. Rev., CD003878.10.1002/14651858.CD003878.pub5 ↗
20. Clinical efficacy of immediate implant loading protocols compared to conventional loading depending on the type of the restoration: A systematic review10.1111/clr.12428 ↗
21. Loading protocols for single-implant crowns: A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.1 ↗
22. World Medical Association (2013). World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects. JAMA, 310, 2191.10.1001/jama.2013.281053 ↗
23. Schulz, K.F., Altman, D.G., and Moher, D. (2010). CONSORT 2010 statement: Updated guidelines for reporting parallel group randomised trials. BMC Med., 8.10.1186/1741-7015-8-18 ↗
24. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants10.1034/j.1600-0501.1997.080302.x ↗
25. Misch, C.E. (1993). Density of bone: Effect on treatment planning, surgical approach, and healing. Contemporary Implant Dentistry, Mosby-Year Book, Inc.
26. Template-guided vs. non-guided drilling in site preparation of dental implants10.1007/s00784-014-1346-7 ↗
27. Survival of short dental implants≤ 7 mm: A review
28. Impact of implant length and diameter on survival rates10.1111/j.1600-0501.2006.01349.x ↗
29. Five-Year Survival Distributions of Short-Length (10 mm or less) Machined-Surfaced and Osseotite® Implants10.1111/j.1708-8208.2004.tb00023.x ↗
30. Failure rates of short (≤10 mm) dental implants and factors influencing their failure: A systematic review
31. Short implants-an analysis of longitudinal studies
32. A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up
33. Implant survival to 36 months as related to length and diameter10.1902/annals.2000.5.1.22 ↗
34. Interventions for Dental Implant Placement in Atrophic Edentulous Mandibles: Vertical Bone Augmentation and Alternative Treatments. A Meta-Analysis of Randomized Clinical Trials10.1902/jop.2016.160226 ↗
35. Short dental implants: A systematic review10.1177/0022034511425675 ↗
36. Long-term Outcomes of Immediate Loading of Short Implants: A Controlled Retrospective Cohort Study10.11607/jomi.5330 ↗
37. Long-term outcomes of short dental implants supporting single crowns in posterior region: A clinical retrospective study of 5–10 years10.1111/j.1600-0501.2012.02452.x ↗
38. Implant loading protocols for partially edentulous patients with extended edentulous sites—A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.2 ↗
39. Methods used to assess implant stability: Current status
40. Bone quality and the immediate loading of implants-critical aspects based on literature, research, and clinical experience10.1097/ID.0b013e3181991248 ↗
41. Survival and success rates of immediately and early loaded implants: 12-month results from a multicentric randomized clinical study10.1563/AAID-JOI-D-10-00149 ↗
42. Immediate loading of mandibular dental implants in partially edentulous patients: A prospective randomized comparative study
43. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
44. Changes in stability after healing of immediately loaded dental implants
45. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
46. Implant stability measurement of delayed and immediately loaded implants during healing10.1111/j.1600-0501.2004.01042.x ↗
47. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation10.1111/j.1600-0501.2007.01336.x ↗
48. How much bone loss can be prevented by alveolar ridge preservation? Systematic literature review and meta-analysis
49. The proportion of cancellous bone as predictive factor for early marginal bone loss around implants in the posterior part of the mandible10.1111/clr.12398 ↗
50. A 5-year prospective clinical and radiographic study of non-submerged dental implants
51. Immediate versus early loading of 6.5 mm-long flapless-placed single implants: A 4-year after loading report of a split-mouth randomised controlled trial
52. The influence of insertion torque on the survival of immediately placed and restored single-tooth implants
53. Application of finite element analysis in implant dentistry: A review of the literature10.1067/mpr.2001.115251 ↗
54. Primary stability and self-tapping blades: Biomechanical assessment of dental implants in medium-density bone10.1111/j.1600-0501.2010.02089.x ↗
55. Peri-implant crestal bone preservation: Where do we stand?10.5005/JP-Journals-10012-1096 ↗
56. The influence of thread geometry on implant osseointegration under immediate loading: A literature review10.4047/jap.2014.6.6.547 ↗
57. Early loading of splinted implants supporting a two-unit fixed partial denture in the posterior maxilla: 13-month results from a randomized controlled clinical trial of two different implant systems10.1111/clr.12667 ↗
58. The wide fixture: A solution for special bone situations and a rescue for the compromised implant. Part 1
59. Five-mm-diameter implants without a smooth surface collar: Report on 98 consecutive placements