The Dependence of Spontaneous Charge Generation in Water on its Flow Rate in a Flow-Based Analytical System
Source abstract
Abstract
Highly sensitive biosensor systems are particularly sensitive to the charge state of an analyte. This charge state can have either a positive (for instance, in case of increasing the efficiency of fishing of low-abundant proteins) or negative effect (for instance, in case of the appearance of charge jumps upon the injection of analyte solution into a measuring cell, what can cause undesirable parasitic signals). Previously, it was demonstrated that upon the pumping of analyte solution through polymeric communications of biosensors with a peristaltic pump at a low (~1 mL/min) flow rate, an accumulation of charge, transferred by the liquid drops from the feeding system into the measuring cell, is observed. At this point, the time dependence of charge accumulation has a linear-stepwise form. In the present study, the influence of the flow rate of water on the parameters of the time dependence of the accumulation of charge in such a system—including the influence on the stepwise charge accumulation—has been investigated. The measurements have been performed with a highly sensitive electrometer sensor at 38 °C, which corresponds to a pathological state of a human body. It has been found that a linear-stepwise time dependence of charge accumulation is observed in a wide range of water flow rates (V= 0.9 to 7.2 mL/min). At that point, upon increasing the flow rate with the transition from the drop-by-drop mode of water supply (0.9 mL/min) to the jet flow (7.2 mL/min), an increase in the absolute value of accumulated charge is observed, but the magnitude of the charge jumps does not change significantly. Thus, the amount of charge accumulated in the cell ambiguously depends on the water flow rate—i.e., this dependence can be non-linear. Accounting for the discovered phenomenon is important in the development of new, more accurate models describing physicochemical properties of aqueous solutions and hemodynamics. This effect should also be taken into account in the development of highly sensitive diagnostic systems intended for the detection of single biomarkers of pathologies in humans and crops, as well as in other living systems. In low-concentration systems, the occurrence of a charge can become a significant factor affecting the efficiency of detection of biomolecules and the reliability of the data obtained. The detection of biomolecules present in the solution at low concentrations is in high demand in medical diagnostics for the revelation of biomarkers at the early asymptomatic stage of various diseases, including aggressive forms of cancer.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Electrohydrodynamics and Fluid Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Biomedical Chemistry, 10, Pogodinskaya St., 119121 Moscow, Russia
Funding
The present study was performed in the framework of the Program for Basic Research of State Academies of Sciences for 2013-2020.
References (35)
Show source-provided references
1. Combined use of irreversible binding and MRM technology for low- and ultralow copy-number protein detection and quantitation10.1002/pmic.201100460 ↗
2. Highly sensitive protein detection by biospecific AFM-based fishing with pulsed electrical stimulation10.1002/2211-5463.12253 ↗
3. Highly sensitive AFM-fishing of albumin
4. Biospecific irreversible fishing coupled with atomic force microscopy for detection of extremely low-abundant proteins10.1002/pmic.200800598 ↗
5. SOI nanowire for the high-sensitive detection of HBsAg and α-fetoprotein10.1039/c2lc40555e ↗
6. Detection of marker miRNAs in plasma using SOI—NW biosensor10.1016/j.snb.2018.01.153 ↗
7. Böcker, J. (1997). Chromatographie. Instrumentelle Analytik mit Chromatographie und Kapillarelektrophorese, Vogel Industrie Medien GmbH & Co KG.
8. AFM-based protein fishing in the pulsed electric field
9. Numerical study on transient induced-charge electro-osmotic flow in a cavity10.1016/j.colsurfa.2010.10.010 ↗
10. Strain-Induced Reversal of Charge Transfer in Contact Electrification10.1002/anie.201107256 ↗
11. Flow-driven voltage generation in carbon nanotubes10.1007/BF03010445 ↗
12. Enabling the enhancement of electroosmotic flow over superhydrophobic surfaces by induced charges10.1016/j.colsurfa.2010.09.002 ↗
13. Surface Potential at the air-water interface computed using density functional theory10.1021/jz900268s ↗
14. Squeezing out hydrated protons: Low-frictional-energy triboelectric insulator charging on a microscopic scale10.1063/1.3592522 ↗
15. Electrostatic charging due to separation of ions at interfaces: Contact electrification of ionic electrets10.1002/anie.200701812 ↗
16. Surface charge printing for programmed droplet transport10.1038/s41563-019-0440-2 ↗
17. A semi-quantitative tribo-electric series for polymeric materials: The influence of chemical structure and properties10.1016/j.elstat.2004.05.005 ↗
18. Lyklema, J. (2005). Fundamentals of Interface and Colloid Science: Soft Colloids, Elsevier.
19. Harvesting water drop energy by a sequential contact-electrification and electrostatic-induction process10.1002/adma.201400373 ↗
20. Electrical power generation by mechanicallymodulating electrical double layers10.1038/ncomms2485 ↗
21. Investigation of surface charge density on solid–liquid interfaces by modulating the electrical double layer10.1088/0953-8984/27/19/194102 ↗
22. Spontaneous electrification of fluoropolymer–water interfaces probed by electrowetting10.1039/C6FD00245E ↗
23. Water-Through triboelectric nanogenerator based on ti-mesh for harvesting liquid flow10.3938/jkps.72.499 ↗
24. Electrical charges and liquids motion10.1016/j.elstat.2009.01.038 ↗
25. A physicochemical explanation for flow electrification in low-conductivity liquids10.1109/28.536865 ↗
26. Demonstration of the triboelectricity effect by the flow of liquid water in the insulating pipe10.1016/j.elstat.2011.06.004 ↗
27. Spontaneous electrical charging of droplets by conventional pipetting10.1038/srep02037 ↗
28. Highly sensitive protein detection by combination of atomic force microscopy fishing with charge generation and mass spectrometry analysis10.1111/febs.13011 ↗
29. Ultrasensitive protein detection using lithographically defined Si multi-nanowire field effect transistors10.1039/c0lc00605j ↗
30. Ivanov, Y.D., Kozlov, A.F., Galiullin, R.A., Kolesanova, E.F., and Pleshakova, T.O. (2017). Spontaneous charge generation in flowing albumin solutions at 35°C and 38°C. Biosensors, 7.10.3390/bios7040060 ↗
31. Generation and accumulation of charge in a flow system for detecting protein markers of diseases
32. Spontaneous generation of charge in the flow-based AFM fishing system10.1016/j.elstat.2017.11.003 ↗
33. Conversion of ortho-para H2O isomers in water and a jump in erythrocyte fluidity through a microcapillary at a temperature of 36.6±0.3 °C10.3103/S1541308X09040025 ↗
34. Two types of anomalous thermodynamics of water
35. Vorobyova, E.A., Gubar, A.V., and Safyannikova, E.B. (2009). Anatomy and Physiology, Meditsina. [5th ed.].