Donning/Doffing and Arm Positioning Influence in Upper Limb Adaptive Prostheses Control
Source abstract
Abstract
New upper limb prostheses controllers are continuously being proposed in the literature. However, most of the prostheses commonly used in the real world are based on very old basic controllers. One reason to explain this reluctance to change is the lack of robustness. Traditional controllers have been validated by many users and years, so the introduction of a new controller paradigm requires a lot of strong evidence of a robust behavior. In this work, we approach the robustness against donning/doffing and arm position for recently proposed linear filter adaptive controllers based on myoelectric signals. The adaptive approach allows to introduce some feedback in a natural way in real time in the human-machine collaboration, so it is not so sensitive to input signals changes due to donning/doffing and arm movements. The average completion rate and path efficiency obtained for eight able-bodied subjects donning/doffing five times in four days is 95.83% and 84.19%, respectively, and for four participants using different arm positions is 93.84% and 88.77%, with no statistically significant difference in the results obtained for the different conditions. All these characteristics make the adaptive linear regression a potential candidate for future real world prostheses controllers.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Muscle activation and electromyography studies · Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Instituto de Telecomunicaciones y Aplicaciones Multimedia (ITEAM), Departamento de Comunicaciones, Universitat Politècnica de València, 46022 Valencia, Spain
Instituto Universitario de Automática e Informática Industrial, Departamento de Ingeniería de Sistemas y Automática, Universitat Politècnica de València, 46022 Valencia, Spain
Funding
Ministerio de Educación y Cultura
References (51)
Show source-provided references
1. Amputation rehabilitation and prosthetic restoration. From surgery to community reintegration10.1080/09638280410001708850 ↗
2. Estimating the Prevalence of Limb Loss in the United States: 2005 to 205010.1016/j.apmr.2007.11.005 ↗
3. Igual, C., Pardo, L.A., Hahne, J.M., and Igual, J.M. (2019). Myoelectric Control for Upper Limb Prostheses. Electronics, 8.10.3390/electronics8111244 ↗
4. Upper-limb prosthetics: Critical factors in device abandonment10.1097/PHM.0b013e3181587f6c ↗
5. Upper limb prosthesis use and abandonment: A survey of the last 25 years10.1080/03093640600994581 ↗
6. A survey of the satisfaction of upper limb amputees with their prostheses, their lifestyles, and their abilities10.1053/hanthe.2002.v15.01562 ↗
7. Functional outcome of patients with proximal upper limb deficiency–acquired and congenital10.1191/0269215504cr716oa ↗
8. New developments in prosthetic arm systems
9. Selective classification for improved robustness of myoelectric control under nonideal conditions10.1109/TBME.2011.2113182 ↗
10. A robust, real-time control scheme for multifunction myoelectric control10.1109/TBME.2003.813539 ↗
11. Myoelectric signal processing for control of powered limb prostheses10.1016/j.jelekin.2006.08.006 ↗
12. Control of upper limb prostheses: Terminology and proportional myoelectric control—A review10.1109/TNSRE.2012.2196711 ↗
13. Evaluation of EMG pattern recognition for upper limb prosthesis control: A case study in comparison with direct myoelectric control10.1186/s12984-018-0361-3 ↗
14. Robust simultaneous myoelectric control of multiple degrees of freedom in wrist-hand prostheses by real-time neuromusculoskeletal modeling10.1088/1741-2552/aae26b ↗
15. Cortical control of a prosthetic arm for self-feeding10.1038/nature06996 ↗
16. Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use10.1109/TNSRE.2015.2454240 ↗
17. A comparison of pattern recognition control and direct control of a multiple degree-of-freedom transradial prosthesis10.1109/JTEHM.2016.2616123 ↗
18. Phinyomark, A.N., Khushaba, R., and Scheme, E. (2018). Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors. Sensors, 18.10.3390/s18051615 ↗
19. Myoelectric control systems—A survey10.1016/j.bspc.2007.07.009 ↗
20. Detection of and compensation for EMG disturbances for powered lower limb prosthesis control10.1109/TNSRE.2015.2413393 ↗
21. Rahimi, A., Benatti, S., Kanerva, P., Benini, L., and Rabaey, J.M. (2016, January 7–9). Hyperdimensional biosignal processing: A case study for EMG-based hand gesture recognition. Proceedings of the 2016 IEEE International Conference on Rebooting Computing (ICRC), Washington, DC, USA.10.1109/ICRC.2016.7738683 ↗
22. Surface EMG in advanced hand prosthetics10.1007/s00422-008-0278-1 ↗
23. Regression convolutional neural network for improved simultaneous EMG control10.1088/1741-2552/ab0e2e ↗
24. Linear and nonlinear regression techniques for simultaneous and proportional myoelectric control10.1109/TNSRE.2014.2305520 ↗
25. Jiang, N., Dosen, S., Muller, K., and Farina, D. (2012). Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus?. IEEE Signal Process. Mag., 29, Available online: https://ieeexplore.ieee.org/document/6279589.10.1109/MSP.2012.2203480 ↗
26. Real-Time, Simultaneous Myoelectric Control Using Force and Position-Based Training Paradigms10.1109/TBME.2013.2281595 ↗
27. Neuronal ensemble control of prosthetic devices by a human with tetraplegia10.1038/nature04970 ↗
28. Interface Prostheses With Classifier-Feedback-Based User Training10.1109/TBME.2016.2641584 ↗
29. Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis10.1186/s12984-019-0545-5 ↗
30. Sensory and motor parameter estimation for elbow myoelectric control with vibrotactile feedback10.1016/j.rehab.2018.05.1090 ↗
31. Myocontrol is closed-loop control: Incidental feedback is sufficient for scaling the prosthesis force in routine grasping10.1186/s12984-018-0422-7 ↗
32. Recent advances in bioelectric prostheses10.1212/CPJ.0000000000000132 ↗
33. Jiang, N., and Farina, D. (2014). Myoelectric control of upper limb prosthesis: Current status, challenges and recent advances. Front. Neuroeng., 4.10.3389/conf.fneng.2014.11.00004 ↗
34. Real-time Classification of Non-Weight Bearing Lower-Limb Movements Using EMG to Facilitate Phantom Motor Execution: Engineering and Case Study Application on Phantom Limb Pain10.3389/fneur.2017.00470 ↗
35. Mastinu, E., Ortiz-Catalan, M., and Håkansson, B. (2015, January 25–29). Analog front-ends comparison in the way of a portable, low-power and low-cost EMG controller based on pattern recognition. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.10.1109/EMBC.2015.7318805 ↗
36. Electrode shift and normalization reduce the innervation zone’s influence on EMG10.1249/MSS.0b013e31816c4822 ↗
37. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand10.1016/j.jneumeth.2014.07.016 ↗
38. Resolving the Limb Position Effect in Myoelectric Pattern Recognition10.1109/TNSRE.2011.2163529 ↗
39. Hwang, H.J., Hahne, J., and Mueller, K.R. (2017). Real-time robustness evaluation of regression based myoelectric control against arm position change and donning/doffing. PLoS ONE, 12.10.1371/journal.pone.0186318 ↗
40. The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift10.1109/TBME.2011.2159216 ↗
41. Counteracting Electrode Shifts in Upper-Limb Prosthesis Control via Transfer Learning10.1109/TNSRE.2019.2907200 ↗
42. Cipriani, C., Sassu, R., Controzzi, M., and Carrozza, M.C. (September, January 30). Influence of the weight actions of the hand prosthesis on the performance of pattern recognition based myoelectric control: Preliminary study. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.10.1109/IEMBS.2011.6090468 ↗
43. Amsuess, S., Paredes, L.P., Rudigkeit, N., Graimann, B., Herrmann, M.J., and Farina, D. (2013, January 3–7). Long term stability of surface EMG pattern classification for prosthetic control. Proceedings of the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, Japan.10.1109/EMBC.2013.6610327 ↗
44. Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use10.1682/JRRD.2010.09.0177 ↗
45. Scheme, E., Fougner, A., Stavdahl, O., Chan, A.D.C., and Englehart, K. (September, January 31). Examining the adverse effects of limb position on pattern recognition based myoelectric control. Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, Buenos Aires, Argentina.10.1109/IEMBS.2010.5627638 ↗
46. Dohnálek, P., Gajdoš, P., and Peterek, T. (2013, January 2–4). Human activity recognition on raw sensor data via sparse approximation. Proceedings of the 2013 36th International Conference on Telecommunications and Signal Processing (TSP), Rome, Italy.10.1109/TSP.2013.6614027 ↗
47. Marasco, P.D., Hebert, J.S., Sensinger, J.W., Shell, C.E., Schofield, J.S., Thumser, Z.C., Nataraj, R., Beckler, D.T., Dawson, M.R., and Blustein, D.H. (2018). Illusory movement perception improves motor control for prosthetic hands. Sci. Transl. Med., 10.10.1126/scitranslmed.aao6990 ↗
48. Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant10.1109/TBCAS.2017.2694710 ↗
49. Adaptive Auto-Regressive Proportional Myoelectric Control10.1109/TNSRE.2019.2894464 ↗
50. A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses10.1109/TBME.2005.856295 ↗
51. Concurrent adaptation of human and machine improves simultaneous and proportional myoelectric control10.1109/TNSRE.2015.2401134 ↗