Design of a Coplanar Interlayer Gapped Microstrips Arrangement for Multi-Nuclei (1H, 19F, 31P, and 23Na) Applications in 7T MRI
Source abstract
Abstract
Seven Tesla Magnetic Resonance (MR) systems can obtain high quality anatomical images using protons (1H) and can be used for multinuclear imaging and MR spectroscopy. These imaging modes can also obtain images and metabolic information using other nuclei, such as 19F, 31P, and 23Na. Here, we present an RF coil unit using a microstrip capable of resonating at four frequencies: 300 (1H), 280 (19F), 121 (31P), and 78 (23Na) MHz. The RF unit consists of a single feeding port and four lines that resonate and run a current at their respective frequency. We used the gapped microstrip concept to isolate each conducting line and interleaved the dielectric materials used for each line, thereby reducing the coupling between them. We also analyzed this design using electromagnetic (EM) simulations, and found that the quad tuned arrangement produced low coupling between adjacent current lines and achieved a uniform |B1| field in the z-y plane.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications · Lanthanide and Transition Metal Complexes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering, Medical Campus, Gachon University, Incheon 21936, Korea
Funding
National Research Foundation of Korea · Gil Medical Center, Gachon University
References (53)
Show source-provided references
1. 7 Tesla MRI of the ex vivo human brain at 100 micron resolution10.1038/s41597-019-0254-8 ↗
2. Laader, A., Beiderwellen, K., Kraff, O., Maderwald, S., Wrede, K., Ladd, M.E., Lauenstein, T.C., Forsting, M., Quick, H.H., and Nassenstein, K. (2017). 1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study. PLoS ONE, 12.10.1371/journal.pone.0187528 ↗
3. Clinical applications of 7 T MRI in the brain10.1016/j.ejrad.2011.07.007 ↗
4. Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy10.1002/epi4.12041 ↗
5. Nuclear magnetic resonance in high magnetic field: Application to condensed matter physics10.1016/j.crhy.2017.09.009 ↗
6. Signal-to-noise ratio in MRI10.1259/bjr.71.847.9771379 ↗
7. High field MRI in preclinical research10.1016/j.ejrad.2003.08.007 ↗
8. MRI at 7 Tesla and above: Demonstrated and potential capabilities10.1002/jmri.24573 ↗
9. Simultaneous and interleaved acquisition of NMR signals from different nuclei with a clinical MRI scanner10.1002/mrm.26056 ↗
10. (2021, January 21). A Hybrid Sodium/Proton Double-Resonant Transceiver Array for 9.4 T MRI. Available online: https://ieeexplore.ieee.org/abstract/document/6756178.
11. Multinuclear MRI at Ultrahigh Fields10.1097/RMR.0000000000000201 ↗
12. Anisimov, N., Gulyaev, M., Pavlova, O., Volkov, D., Gervits, L., and Pirogov, Y. (2017). Multinuclear magnetic resonance imaging in biomedical experiments. J. Phys. Conf. Ser., 886.10.1088/1742-6596/886/1/012006 ↗
13. X-nuclei imaging: Current state, technical challenges, and future directions10.1002/jmri.26780 ↗
14. Biomedical applications of sodium MRI in vivo10.1002/jmri.24168 ↗
15. The potential of relaxation-weighted sodium magnetic resonance imaging as demonstrated on brain tumors10.1097/RLI.0b013e31821ae918 ↗
16. Tissue sodium concentration in human brain tumors as measured with 23Na MR imaging10.1148/radiol.2272020483 ↗
17. Sodium MRI of multiple sclerosis10.1002/nbm.3289 ↗
18. Sodium imaging intensity increases with time after human ischemic stroke10.1002/ana.21648 ↗
19. Sodium MRI of the human kidney at 3 Tesla10.1002/mrm.21031 ↗
20. In-vivo 31P-MRS of skeletal muscle and liver: A way for non-invasive assessment of their metabolism10.1016/j.ab.2017.01.018 ↗
21. Bakermans, A.J., Bazil, J.N., Nederveen, A.J., Strijkers, G.J., Boekholdt, S.M., Beard, D.A., and Jeneson, J.A. (2017). Human cardiac 31P-MR spectroscopy at 3 Tesla cannot detect failing myocardial energy homeostasis during exercise. Front. Physiol., 8.10.3389/fphys.2017.00939 ↗
22. Human cardiac 31P magnetic resonance spectroscopy at 7 Tesla10.1002/mrm.24922 ↗
23. Application of 31P MR spectroscopy to the brain tumors10.3348/kjr.2013.14.3.477 ↗
24. Clinical protocols for 31P MRS of the brain and their use in evaluating optic pathway gliomas in children10.1016/j.ejrad.2013.11.009 ↗
25. 31P-MRS of healthy human brain: ATP synthesis, metabolite concentrations, pH, and T1 relaxation times10.1002/nbm.3384 ↗
26. 31P MRSI and 1H MRS at 7 T: Initial results in human breast cancer10.1002/nbm.1696 ↗
27. Liu, Y., Gu, Y., and Yu, X. (2017). Assessing tissue metabolism by phosphorous-31 magnetic resonance spectroscopy and imaging: A methodology review. Quant. Imaging Med. Surg., 7.10.21037/qims.2017.11.03 ↗
28. Lee, D., and Marcinek, D. (2009). Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures. JOVE, 32.10.3791/1592 ↗
29. 19F MRI for quantitative in vivo cell tracking10.1016/j.tibtech.2010.04.002 ↗
30. 19F-MRI of perfluorononane as a novel contrast modality for gastrointestinal imaging10.1002/(SICI)1522-2594(199901)41:1<80::AID-MRM12>3.0.CO;2-6 ↗
31. 19F magnetic resonance imaging of the reticuloendothelial system10.1002/mrm.1910050605 ↗
32. Han, S.D., Heo, P., Kim, H.J., Song, H., Kim, D., Seo, J.H., Ryu, Y., Noh, Y., and Kim, K.N. (2017). Double-layered dual-tuned RF coil using frequency-selectable PIN-diode control at 7-T MRI. Concepts Magn. Reson. B, 47.10.1002/cmr.b.21363 ↗
33. A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI10.1259/bjr.71.841.9534700 ↗
34. (2021, January 21). Effects of Tuning Condition, Head Size and Position on the SAR of MRI Dual-Row Transmit Arrays. EuMC. Available online: https://ieeexplore.ieee.org/document/6686754.
35. Microstrip RF surface coil design for extremely high-field MRI and spectroscopy10.1002/mrm.1212 ↗
36. Mahendra, A., and Rahardjo, E.T. (2019, January 23–25). Numerical Design of Dual Resonant Microstrip Surface RF Coil for MRI Application. Proceedings of the 2019 IEEE Conference on Antenna Measurements & Applications (CAMA), Bali, Indonesia.10.1109/CAMA47423.2019.8959540 ↗
37. Aliane, K., Benahmed, N., Bouhmidi, R., Meriah, S.M., Bendimerad, F.T., and Benabdallah, N. (2012, January 27–30). Analysis and Design of a 12-Element Coupled-Microstrip-Line quasi-TEM Resonator for MRI. Proceedings of the 2012 Spring Congress on Engineering and Technology, Xi’an, China.10.1109/SCET.2012.6342148 ↗
38. A microstrip transmission line volume coil for human head MR imaging at 4 T10.1016/S1090-7807(03)00004-1 ↗
39. RF coils: A practical guide for nonphysicists10.1002/jmri.26187 ↗
40. Equivalent capacitances of coplanar waveguide discontinuities and interdigitated capacitors using a three-dimensional finite difference method10.1109/22.64560 ↗
41. Comparison between theoretical and measured microstrip gap parameters involving anisotropic substrates10.1109/22.660989 ↗
42. Kompa, G. (2005). Practical Microstrip Design and Applications, Artech House.
43. An analysis of gap in microstrip transmission lines10.1109/TMTT.1972.1127768 ↗
44. Kirschning, M. (1984). Entwicklung von Näherungsmodellen für den Rechnergestützten Entwurf von Hybriden und Monolithischen Schaltungen in Mikrostreifenleitungstechnik. [Ph.D. Thesis, Universität Duisburg].
45. Measurement and computer-aided modeling of microstrip discontinuities by an improved resonator method10.1109/MWSYM.1983.1130959 ↗
46. (2020, October 08). Quite Universal Circuit Simulator. Available online: http://qucs.sourceforge.net/index.html.
47. Accurate model for open end effect of microstrip lines10.1049/el:19810088 ↗
48. Coupling between microstrip lines with finite width ground plane embedded in thin-film circuits10.1109/TADVP.2005.846933 ↗
49. Parameters of microstrip transmission lines and of coupled pairs of microstrip lines10.1109/TMTT.1968.1126858 ↗
50. Coupled-mode analysis of line parameters of coupled microstrip lines10.2528/PIER99032902 ↗
51. Planar strip array (PSA) for MRI10.1002/mrm.1090 ↗
52. Efficient calculation of interconnect capacitance and characteristic impedance for coupled pairs of microstrip-like transmission lines
53. (2020, October 06). Sim4Life by ZMT. Available online: www.zurichmedtech.com.