journal article·2021-06-29Open access

Minimum Representative Human Body Model Size Determination for Link Budget Calculation in Implanted Medical Devices

Iñaki Ortego-Isasa, Ainhoa Rezola, Yue Gao, Xiaodong Chen, Daniel Valderas

Applied Sciences· Volume 11· Issue 13

Abstract

In this work, the optimum homogeneous phantom size for an equivalent whole-body electromagnetic (EM) modeling is calculated. This will enable the simple characterization of plane wave EM attenuation and far-field link budgets in Active Medical Implant (AMI) applications in the core region of the body for Industrial, Scientific, Medical and MedRadio frequency bands. A computational analysis is done to determine the optimum size in which a minimum phantom size reliably represents a whole-body situation for the corresponding frequency of operation, saving computer and laboratory resources. After the definition of a converge criterion, the computed minimum phantom size for subcutaneous applications, 0–10 mm insertion depth, is 355 × 160 × 255 mm3 for 402 MHz and 868 MHz and a cube with a side of 100 mm and 50 mm for 2.45 GHz and 5.8 GHz, respectively. For deep AMI applications, 10–50 mm insertion depth, the dimensions are 355 × 260 × 255 mm3 for 402 MHz and 868 MHz, and a cube with a side of 200 mm and 150 mm for 2.45 GHz and 5.8 GHz, respectively. A significant reduction in both computational and manufacturing resources for phantom development is thereby achieved. The verification of the model is performed by field measurements in phantoms made by aqueous solutions with sugar.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wireless Body Area Networks · Wireless Power Transfer Systems · Electromagnetic Fields and Biological Effects

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

TECNALIA, Basque Research and Technology Alliance (BRTA), Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastián, Spain

Department of Electrical and Electronic Engineering, TECNUN, University of Navarra, Mikeletegi Pasealekua 48, 20009 Donostia-San Sebastián, Spain

Institute for Communication Systems/5GIC/6GIC, School of Computer Science and Electronic Engineering, University of Surrey, Guildford GU2 7XH, UK

School of Electronic Engineering and Computer Science, Queen Mary University of London, Mile End Rd, Bethnal Green, London E1 4NS, UK

CEIT, Basque Research and Technology Alliance (BRTA), Manuel Lardizabal 13, 20018 Donostia-San Sebastián, Spain

Funding

Eusko Jaurlaritza · Ministerio de Economía y Competitividad

References (35)

Show source-provided references
1. Vander Vorst, A., Rosen, A., and Kotsuka, Y. (2006). RF/Microwave Interaction with Biological Tissues, John Wiley & Sons.10.1002/0471752053 ↗
2. Peter, Y.H., and Hall, S. (2006). Antennas and Propagation for Body-Centric Wireless Communications, Artech House.
3. Bakker, J. (2012). Dosimetry of Exposure to Electromagnetic Fields in Daily Life and Medical Applications, Erasmus Universiteit Rotterdam.
4. Evaluation of Wireless Resonant Power Transfer Systems with Human Electromagnetic Exposure Limits
5. Wilén, J. (2002). Radiofrequency Fields—Exposure, Dose and Health. [Ph.D. Thesis, Umeå Universitet]. ISSN 0346-6612.
6. Vecchia, P., Matthes, R., Ziegelberger, G., Lin, J., Saunders, R., and Swerdlow, A. (2009). Exposure to High Frequency Electromagnetic Fields, Biological Effects and Health Consequences (100 kHz–300 GHz), International Commission on Non-Ionizing Radiation Protection.
7. Effects of Exposure to Very High Frequency Radiofrequency Radiation on Six Antenna Engineers in Two Separate Incidents10.1093/occmed/50.1.49 ↗
8. (2018). Implantable Medical Devices Market (Product—Reconstructive Joint Replacement, Spinal Implants, Dental Implants, and Cardiovascular Implants; Material—Titanium, Stainless Steel, Titanium Alloy, CoCr Alloy, and Zirconium)—Global Industry Analysis, Size, Share, Growth, Trends, and Forecast 2019–2027. Transpar. Mark. Res., Available online: https://www.transparencymarketresearch.com/pressrelease/global-implantable-medical-devices-market.htm.
9. SAR Comparison of SAM Phantom and Anatomical Head Models for a Typical Bar-Type Phone Model10.1109/TEMC.2015.2433314 ↗
10. IEEE Standards Coordinating Committee 34 (2013). IEEE Draft Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques, Institute of Electrical and Electronic Engineers.
11. The dependence of electromagnetic energy absorption upon human head tissue composition in the frequency range of 300–3000 MHz10.1109/22.884187 ↗
12. The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz10.1109/TMTT.2006.872789 ↗
13. Merli, F., Bolomey, L., Zürcher, J.-F., Meurville, E., and Skrivervik, A.K. (2011, January 11–15). Versatility and tunability of an implantable antenna for telemedicine. Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP), Rome, Italy.
14. Felicio, J.M., Fernandes, C.A., and Costa, J.R. (July, January 26). Comparing liquid homogeneous and multilayer phantoms for human body implantable antennas. Proceedings of the 2016 IEEE International Symposium on Antennas and Propagation (APSURSI), Fajardo, PR, USA.10.1109/APS.2016.7696232 ↗
15. Accelerated Design of Optimized Implantable Antennas for Medical Telemetry10.1109/LAWP.2013.2238499 ↗
16. Dielectric Properties of Tissue-Equivalent Liquids and Their Effects on Specific Absorption Rate10.1109/TEMC.2004.823624 ↗
17. (2021, April 01). MCL Technology, Available online: http://www.mcluk.gov.org.
18. (2021, May 05). Schmid & Partner Engineering AG. Available online: http://www.speag.com.
19. Limited Warranty on Phantoms (2021, May 05). Schmid & Partner Engineering AG (SPEAG). Available online: https://speag.swiss/assets/downloads/products/dasy/free_downloads/921-Phantoms-DGBE-A.pdf.
20. RF Channel Modeling for Implant-to-Implant Communication and Implant to Subcutaneous Implant Communication for Future Leadless Cardiac Pacemakers10.1109/TBME.2018.2817690 ↗
21. Implanted stimulators for restoration of function in spinal cord injury10.1016/S1350-4533(01)00012-1 ↗
22. Wang, P.-M., Dubrovsky, G., Dunn, J.C., Lo, Y.-K., and Liu, W. (2019). A Wireless Implantable System for Facilitating Gastrointestinal Motility. Micromachines, 10.10.3390/mi10080525 ↗
23. Broadband UHF Implanted 3-D Conformal Antenna Design and Characterization for In-Off Body Wireless Links10.1109/TAP.2013.2295816 ↗
24. Electronic Communications Committee (ECC) (2002). Ultra Low Power Active Medical Implant Systems (ULP-AMI), ECC.
25. The Dielectric Properties of Biological Tissues: I. Literature survey10.1088/0031-9155/41/11/001 ↗
26. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz10.1088/0031-9155/41/11/002 ↗
27. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues10.1088/0031-9155/41/11/003 ↗
28. Balanis, C.A. (2012). Advanced Engineering Electromagnetics, John Willey & Sons, Inc.. [2nd ed.].
29. Keysight Technologies (2021, May 05). Basics of Measuring the Dielectric Properties of Materials (5989-2589EN). Available online: https://www.keysight.com/es/en/assets/7018-01284/application-notes/5989-2589.pdf.
30. KeySight Technologies (2021, May 05). 85070E Dielectric Probe Kit. Available online: http://www.keysight.com/en/pd-304506-pn-85070E/dielectric-probe-kit?cc=ES&lc=eng.
31. KeySight Technologies (2021, May 05). E8362B PNA Network Analyzer, 10 MHz to 20 GHz. Available online: http://www.keysight.com/en/pd-72279-pn-E8362B/pna-series?cc=ES&lc=eng.
32. ETS LINDGREN (2005). Dual Polarized Horns—Model 3164, ESCO Technologies Inc.10.1016/S1365-6937(05)00579-4 ↗
33. Valderas, D., Schmidt, C., and Chen, X. (2010, January 11–17). Broadband implanted UHF RFID antenna. Proceedings of the 2010 IEEE Antennas and Propagation Society International Symposium, Toronto, ON, Canada.10.1109/APS.2010.5561741 ↗
34. An estimation of the number of cells in the human body10.3109/03014460.2013.807878 ↗
35. A new gas dilution method for measuring body volume10.1136/bjsm.29.2.134 ↗