journal article·2021-12-02Open access

Development of a Proton-Frequency-Transparent Birdcage Radiofrequency Coil for In Vivo 13C MRS/MRSI Study in a 3.0 T MRI System

Jun-Sik Yoon, Jong-Min Kim, Han-Jae Chung, You-Jin Jeong, Gwang-Woo Jeong, Ilwoo Park, Gwang-Won Kim, Chang-Hyun Oh

Applied Sciences· Volume 11· Issue 23

Abstract

A proton-frequency-transparent (PFT) birdcage RF coil that contains carbon-proton switching circuits (CPSCs) is presented to acquire 13C MR signals, which, in turn, enable 1H imaging with existing 1H RF coils without being affected by a transparent 13C birdcage RF coil. CPSCs were installed in the PFT 13C birdcage RF coil to cut the RF coil circuits during 1H MR imaging. Finite-difference time-domain (FDTD) electromagnetic (EM) simulations were performed to verify the performance of the proposed CPSCs. The performance of the PFT 13C birdcage RF coil with CPSCs was verified via phantom and in vivo MR studies. In the phantom MR studies, 1H MR images and 13C MR spectra were acquired and compared with each other using the 13C birdcage RF coil with and without the CPSCs. For the in vivo MR studies, hyperpolarized 13C cardiac MRS and MRSI of swine were performed. The proposed PFT 13C birdcage RF coil with CPSCs led to a percent image uniformity (PIU) reduction of 1.53% in the proton MR images when compared with the case without it. FDTD EM simulations revealed PIU reduction of 0.06% under the same conditions as the phantom MR studies. Furthermore, an SNR reduction of 5.5% was observed at 13C MR spectra of corn-oil phantom using the PFT 13C birdcage RF coil with CPSCs compared with that of the 13C birdcage RF coil without CPSCs. Utilizing the PFT 13C birdcage RF coil, 13C-enriched compounds were successfully acquired via in vivo hyperpolarized 13C MRS/MRSI experiments. In conclusion, the applicability and utility of the proposed 16-leg low-pass PFT 13C birdcage RF coil with CPSCs were verified via 1H MR imaging and hyperpolarized 13C MRS/MRSI studies using a 3.0 T MRI system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications · Atomic and Subatomic Physics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronics and Information Engineering, Korea University, Sejong 30019, Korea

Research Institute for Advanced Industrial Technology, Korea University, Sejong 30019, Korea

Department of Radiology, Chonnam National University Medical School and Hospital, Gwangju 61469, Korea

Department of Artificial Intelligence Convergence, Chonnam National University, Gwangju 61186, Korea

Department of Psychiatry, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA

Funding

Ministry of Trade, Industry and Energy · Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety

References (39)

Show source-provided references
1. Generating highly polarized nuclear spins in solution using dynamic nuclear polarization10.1016/j.nima.2004.03.171 ↗
2. Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR10.1073/pnas.1733835100 ↗
3. MR spectroscopy of the liver: Principles and clinical applications10.1148/rg.296095520 ↗
4. Real-time metabolic imaging10.1073/pnas.0601319103 ↗
5. DNP-Hyperpolarized 13C Magnetic Resonance Metabolic Imaging for Cancer Applications10.1007/s00723-008-0136-2 ↗
6. Dual-frequency, dual-quadrature, birdcage RF coil design with identical b1 pattern for sodium and proton imaging of the human brain at 1.5 T10.1002/mrm.1910380507 ↗
7. A PIN diode controlled dual-tuned MRI RF coil and phased array for multi nuclear imaging10.1088/0031-9155/55/9/011 ↗
8. Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3 T10.1016/j.mri.2011.12.011 ↗
9. Construction and evaluation of a switch-tuned 13C-1H birdcage radiofrequency coil for imaging the metabolism of hyperpolarized 13C-enriched compounds10.1002/jmri.24458 ↗
10. An Improved Trap Design for Decoupling Multinuclear RF Coils10.1002/mrm.24931 ↗
11. In vivo self-gated 23 Na MRI at 7 T using an oval-shaped body resonator10.1002/mrm.27103 ↗
12. Cardiorenal sodium MRI at 7.0 Tesla using a 4/4 channel 1 H/ 23 Na radiofrequency antenna array10.1002/mrm.27880 ↗
13. High performance radiofrequency coils for 23Na MRI: Brain and musculoskeletal applications10.1002/nbm.3379 ↗
14. Dynamic MRS and MRI of skeletal muscle function and biomechanics10.1002/nbm.1095 ↗
15. Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles Using a Dual-Frequency Coil Array10.1038/srep30568 ↗
16. Multiple tuning of birdcage resonators10.1002/mrm.1910370217 ↗
17. A practical double-tuned 1H/31P quadrature birdcage headcoil optimized for 31P operation10.1002/(SICI)1522-2594(199907)42:1<173::AID-MRM23>3.0.CO;2-O ↗
18. Mispelter, J., Lupu, M., and Briguet, A. (2015). NMR Probeheads for Biophysical and Biomedical Experiments: Theoretical Principles and Practical Guidelines, Imperial College Press.
19. Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head10.1006/jmrb.1994.1017 ↗
20. Cardiac metabolism measured noninvasively by hyperpolarized13C MRI10.1002/mrm.21460 ↗
21. Metabolic biomarkers for non-alcoholic fatty liver disease induced by high-fat diet: In vivo magnetic resonance spectroscopy of hyperpolarized [1-13C] pyruvate10.1016/j.bbrc.2016.08.118 ↗
22. Metabolic alterations in a rat model of hepatic ischaemia reperfusion injury: In vivo hyperpolarized 13 C MRS and metabolic imaging10.1111/liv.13695 ↗
23. Methods for the analysis and design of a solid state nuclear magnetic resonance probe10.1063/1.1149104 ↗
24. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
25. Practical aspects of birdcage coils10.1006/jmre.1998.1703 ↗
26. Spatial requirements of animals: Allometry and beyond10.1016/j.jveb.2007.10.001 ↗
27. Comparison of linear and circular polarization for magnetic resonance imaging
28. BirdcageBuilder: Design of specified-geometry birdcage coils with desired current pattern and resonant frequency10.1002/cmr.10030 ↗
29. Common-Mode Differential-Mode (CMDM) Method for Double Nuclear MR Signal Excitation and Reception at Ultrahigh Fields10.1109/TMI.2011.2160192 ↗
30. Analysis and design of lumped-and lumped-distributed-element directional couplers for MIC and MMIC applications10.1109/22.120097 ↗
31. A fast recovery probe and receiver for pulsed nuclear magnetic resonance spectroscopy10.1088/0022-3735/1/3/312 ↗
32. American College of Radiology (ACR) (1998). Phantom Test Guidance for the ACR MRI Accreditation Program, ACR.
33. Clarke, G.D. (2004). Overview of the ACR MRI Accreditation Phantom, University of Texas Southwestern Medical Center.
34. Accurate flip-angle calibration for 13C MRI10.1002/mrm.21252 ↗
35. A fast and simple method for calibrating the flip angle in hyperpolarized13C MRS experiments10.1002/cmr.b.21282 ↗
36. SIVIC: Open-source, standards-based software for DICOM MR spectroscopy workflows10.1155/2013/169526 ↗
37. Hyperpolarized 13C metabolic magnetic resonance spectroscopy and imaging
38. Metabolic cardioprotection by pyruvate: Recent progress10.1177/153537020523000701 ↗
39. Dynamic 2D and 3D mapping of hyperpolarized pyruvate to lactate conversion in vivo with efficient multi-echo balanced steady-state free precession at 3 T10.1002/nbm.4291 ↗