journal article·2024-01-12Open access

The Preliminary Development of a Friction-Based Lateral Screw-Retained Dental Crown—A Comparison between the Prototype Surface Treatment and the Retention Strength

Sugeng Supriadi, Yudan Whulanza, Tri Ardi Mahendra, Ratna Sari Dewi, Lindawati S. Kusdhany, Pelangi Raihan Mathar, Rizki Aldila Umas

Applied Sciences· Volume 14· Issue 2

Abstract

This study aims to develop a novel retention method combining the retrievability of the screw retention method with the ideal occlusal table and the aesthetic capability of cement retention. Coping was developed to have lateral screw access, allowing the screw to lock the coping using lateral forces from screw tightening and friction between the tip of the screw and the sandblasted surface of an abutment. Sandblasting parameters varied based on particle size. The results show a positive correlation to surface roughness and indicate a positive correlation to retention force. The highest surface roughness and retention force result was shown by groups that were sandblasted using 686 μm of aluminum oxide. Experiments on the tightening strength of 48 subjects measured in simulated conditions similar to the assembly conditions of lateral screw retention implants resulted in a mean of 69.75 Nmm with the highest and lowest values of 120.67 Nmm and 34.67 Nmm. This result became the basis of tightening torque variation. Each group’s retention capability is measured and compared to cement-retained dental implants. The results show that the tightening torque correlates positively with retention force, with the highest average retention score showed by lateral screws retained under a tightening torque of 200 Nmm—317.87 N higher than cement-retained screws.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia

Research Center for Biomedical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia

Department of Prosthodontics, Faculty of Dentistry, Universitas Indonesia, Depok 16424, Indonesia

Funding

Directorate of Research and Development, Universitas Indonesia

References (60)

Show source-provided references
1. Improvements in Implant Dentistry over the Last Decade: Comparison of Survival and Complication Rates in Older and Newer Publications10.11607/jomi.2014suppl.g5.2 ↗
2. Resnik, R. (2019). Misch’s Contemporary Implant Dentistry, Elsevier. [4th ed.].
3. Reda, R., Zanza, A., Cicconetti, A., Bhandi, S., Guarnieri, R., Testarelli, L., and Di Nardo, D. (2022). A Systematic Review of Cementation Techniques to Minimize Cement Excess in Cement-Retained Implant Restorations. Methods Protoc., 5.10.3390/mps5010009 ↗
4. Survey of Screw-Retained versus Cement-Retained Implant Restorations in Saudi Arabia10.1155/2017/5478371 ↗
5. The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis10.1111/cid.12620 ↗
6. Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial10.4047/jap.2019.11.3.147 ↗
7. Common Prosthetic Implant Complications in Fixed Restorations
8. Screw retained vs. cement retained implant-supported fixed dental prosthesis10.1111/prd.12168 ↗
9. Screw- Versus Cement-Retained Implant Prostheses: A Systematic Review of Prosthodontic Maintenance and Complications10.11607/ijp.3947 ↗
10. Application of Semipermanent Cements and Conventional Cement with Modified Cementing Technique in Dental Implantology10.15644/asc55/4/4 ↗
11. Comparison of Oxygen Plasma Treatment and Sandblasting of Titanium Implant-Abutment Surface on Bond Strength and Surface Topography
12. The Effect of Different Surface Treatments on Cement-Retained Implant-Supported Restorations10.1563/AAID-JOI-D-10-00151 ↗
13. The effect of surface texture on the retention of single implant-supported crowns cemented on wide-platform abutments10.15448/1980-6523.2017.4.28739 ↗
14. Effect of axial wall modification on the retention of cement-retained, implant-supported crowns10.1016/S0022-3913(12)60028-6 ↗
15. Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns
16. Effect of abutment modification and cement type on retention of cement-retained implant supported crowns
17. Effects of Abutment and Screw Access Channel Modification on Dislodgement of Cement-Retained Implant-Supported Restorations10.11607/ijp.3069 ↗
18. An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns10.1016/S0022-3913(11)60149-2 ↗
19. Effect of Metal Extension of Crown in the Screw Access Channel of a Posterior Implant Abutment on the Retention of Cement Retained Prosthesis10.1563/AAID-JOI-D-13-00072 ↗
20. Retention of luting agents on implant abutments of different height and taper10.1111/j.1600-0501.2005.01159.x ↗
21. Cement Selection for Cement-Retained Implant-Supported Prostheses: A Literature Review10.1111/jopr.12361 ↗
22. Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis10.1111/j.1600-0501.2012.02570.x ↗
23. Peri-implant disease caused by residual cement around implant-supported restorations: A clinical report
24. Influence of screw access on the retention of cement-retained implant prostheses10.1016/S0022-3913(13)60055-4 ↗
25. Prosthetic failures in dental implant therapy10.1111/prd.12416 ↗
26. A Systematic Review of Screw versus Cement-Retained Fixed Implant Supported Reconstructions10.2147/CCIDE.S231070 ↗
27. A Comparison Between Screw- and Cement-Retained Implant Prostheses. A Literature Review10.1563/AAID-JOI-D-10-00146 ↗
28. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry10.1016/S0022-3913(97)70203-8 ↗
29. Cemented single crowns on osseointegrated implants after 5 years: Results from a prospective study on CeraOne
30. Cross-pinning: The philosophy of retrievability applied practically to fixed, implant-supported prostheses10.1111/j.1834-7819.2007.00013.x ↗
31. Strategies for restoration of single implants and use of cross-pin retained restorations by Australian prosthodontists10.1111/j.1834-7819.2012.01731.x ↗
32. The cross-pin retained implant supported restoration: A study of gasket placement and leakage10.1111/j.1834-7819.2012.01730.x ↗
33. Sánchez Lasheras, F., Rodríguez, J.G., Mauvezín-Quevedo, M., Martín-Fernández, E., Bobes-Bascarán, J., de Llanos-Lanchares, H., and Álvarez-Arenal, Á. (2019). Does the transversal screw design increase the risk of mechanical complications in dental implants? A finite elements analysis. Int. J. Numer. Methods Biomed. Eng., 35.10.1002/cnm.3205 ↗
34. Effect of Various Particle Size of Sand-blast on Roughness and Shear Bond Strength of Ips E.max Press With Ceramic Veneer Materials (An in Vitro Study)
35. Effect of Cerium on Mechanical, Metallurgical and Biomedical Properties of NiCrMoB Dental Alloy
36. Effect of sandblasting on the surface roughness and residual stress of 3Y-TZP (zirconia)10.1007/s42452-020-03492-6 ↗
37. Yuda, A.W., Supriadi, S., and Saragih, A.S. (2019, January 13–14). Surface modification of Ti-alloy based bone implant by sandblasting. Proceedings of the International Symposium of Biomedical Engineering (ISBE), Padang, Indonesia.10.1063/1.5139335 ↗
38. Tightening torque of implant abutment using hand drivers against torque wrench and its effect on the internal surface of implant10.4103/jips.jips_425_19 ↗
39. Elongation and preload stress in dental implant abutment screws
40. Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants10.4047/jap.2016.8.1.62 ↗
41. Retention Forces of Implant-Supported Single Crowns and Fixed Dental Prostheses after Cementation: An In-Vitro Study10.3390/oral2010005 ↗
42. An in vitro study to compare the influence of newer luting cements on retention of cement-retained implant-supported prosthesis10.4103/jips.jips_235_18 ↗
43. Retention of crowns cemented on implant abutments with temporary cements10.4012/dmj.2014-100 ↗
44. The association of normal mouth opening with gender and height
45. A comparative study of retention of cement retained implant prosthesis cemented with different luting cements10.53730/ijhs.v6nS3.8335 ↗
46. A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment10.4047/jap.2013.5.3.234 ↗
47. Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro10.1186/s40729-021-00349-4 ↗
48. Fracture resistance of different metal substructure designs for implant-supported porcelain-fused-to-metal (PFM) crowns10.1016/j.jds.2013.04.007 ↗
49. Osak, P., Maszybrocka, J., Zubko, M., Rak, J., Bogunia, S., and Łosiewicz, B. (2021). Influence of Sandblasting Process on Tribological Properties of Titanium Grade 4 in Artificial Saliva for Dentistry Applications. Materials, 14.10.3390/ma14247536 ↗
50. Effect of surface treatments on implant crown retention10.1016/S1991-7902(10)60019-0 ↗
51. Jemat, A., Ghazali, M.J., Razali, M., and Otsuka, Y. (2015). Surface Modifications and Their Effects on Titanium Dental Implants. BioMed Res. Int., 2015.10.1155/2015/791725 ↗
52. Effect of surface topography of implant abutments on retention of cemented single-tooth crowns
53. Erdem, M.A., Karatasli, B., Kose, O.D., Kose, T.E., Çene, E., Aya, S.A., and Cankaya, A.B. (2017). The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems. BioMed Res. Int., 2017.10.1155/2017/8652720 ↗
54. Accuracy of Implant Torque Wrenches after Clinical Service10.4103/jid.jid_14_17 ↗
55. Shiba, H., Sato, Y., Furuya, J., Osawa, T., Isobe, A., Hayashi, M., and Kitagawa, N. (2021). Experimental study on the factors affecting torque of beam-type implant torque wrenches. BMC Oral Health, 21.10.1186/s12903-021-01703-z ↗
56. Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: An alternative to the conventional Implant prosthetic system10.4047/jap.2016.8.2.150 ↗
57. The Influence of Implant Abutment Surface Roughness and the Type of Cement on Retention of Implant Supported Crowns
58. Effect of Abutment Height and Cement Thickness on the Retention of Cement-Retained Implant-Supported Restorations
59. Comparison of Push-In versus Pull-Out Tests on Bone-Implant Interfaces of Rabbit Tibia Dental Implant Healing Model10.1111/j.1708-8208.2011.00357.x ↗
60. Analysis of Primary Stability of Dental Implants Inserted in Different Substrates Using the Pullout Test and Insertion Torque10.1155/2013/194987 ↗