journal article·2024-07-15Open access

Orbital-Rail-Type Automatic Inspection Device for Pipeline Welds Using Radiation Dose Prediction Results from FLUKA Simulation

Du-Song Kim, Sung-Hoe Heo, Seung-Uk Heo, Jaewoong Kim

Applied Sciences· Volume 14· Issue 14

Abstract

Pipeline welds typically do not have secondary reinforcement, rendering welds highly vulnerable to leakage accidents caused by the movement of gases or liquids. Therefore, identifying internal defects in welds through radiographic testing (RT) is critical for a visual and quantitative evaluation of weld defects. In this study, we developed a device that can automatically inspect the circumferential connection between pipes by applying a digital radiography testing (DRT) technique that can convert radiation signals into real-time electrical signals by using a digital detector array (DDA). Gamma rays were used to minimize spatial constraints in the inspection environment and optimization was performed to satisfy quality requirements set by international standards. Furthermore, FLUKA simulation was performed to predict radiation intensity for accurate radiation leakage identification to enable the shielding design to be supplemented with lead rubber. This measure considerably reduces the safe distance for radiation leakage during field testing. The results confirmed the feasibility of a novel automated inspection technique that integrates automatic inspection devices and ensures safety using radiation, the byproduct of which is a hazardous material.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Non-Destructive Testing Techniques · Nuclear Physics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Welding Engineering R&D Department, Hanwha Ocean Co., Ltd., Geoje 53302, Republic of Korea

Department of Emergency and Disaster Management, Graduate School, Inje University, Gimhae 50834, Republic of Korea

Non Destructive Test Team, DSEC T&S Co., Ltd., Geoje 53302, Republic of Korea

Safety for Medical Device and Radiation, Yangsan 50654, Republic of Korea

Automotive Materials & Components R&D Group, Korea Institute of Industrial Technology, Gwangju 61012, Republic of Korea

Funding

Ministry of Trade, Industry and Energy · Korea Institute of Industrial Technology

References (30)

Show source-provided references
1. Analysis of the radiological safety control level versus the exposure of radiation workers in South Korea from 2008–201710.1093/rpd/ncy190 ↗
2. Lee, S., Lim, J., and Yi, C.-G. (2022). The improvement of the regional regulatory governance system for radiation risk management: Spatial analysis on radiation hazards in South Korea. Sustainability, 14.10.3390/su14020966 ↗
3. Evaluation of digital detector arrays systems for industrial radiography
4. Automated defect detection in digital radiography of aerospace welds using deep learning10.1007/s40194-022-01257-w ↗
5. Digital radiography using digital detector arrays fulfills critical applications for offshore pipelines10.1155/2010/894643 ↗
6. Generation of radiographic techniques for digital radiography applications
7. Duliu, O.G. (2021). X- and Gamma Ray Imaging (CT, PET and SPEC, Scintigraphy, and Radiography) Benefits and Risks. Medical Imaging Methods, CRC Press. [1st ed.].10.1201/9781003112068-3 ↗
8. Radiographic evaluation of gas tungsten arc welded joints used in nuclear applications by X- and gamma-rays10.1016/j.ndteint.2018.11.017 ↗
9. (2013). Non-destructive testing—Image quality of radiographs. Part 1: Determination of the image quality value using wire-type image quality indicators (Standard No. ISO 19232-1:2013).
10. (2022). Nondestructive testing of welds—Radiographic testing—Part 2: X- and gamma-ray techniques with digital detectors (Standard No. ISO 17636-2:2022).
11. American Society of Mechanical Engineers (ASME) (2013). Boiler and Pressure Vessel Code, Section V: Nondestructive Examination, Article 2: Radiographic Examination, T-270, ASME.
12. A case report: Cytogenetic dosimetry after accidental radiation exposure during 192Ir industrial radiography testing10.1667/RR14013.1 ↗
13. The effective attenuation in water of the gamma rays of gold 198, iridium 192, cesium 137, radium 226, and cobalt 6010.1148/90.5.953 ↗
14. Non-destructive testing of industrial equipment using muon radiography10.1098/rsta.2018.0054 ↗
15. Review of non-destructive testing (NDT) techniques and their applicability to thick walled composites10.1016/j.procir.2015.07.043 ↗
16. Benchmarking FLUKA Monte Carlo code with international measurement standard for air kerma10.1088/1748-0221/15/12/P12014 ↗
17. Standardizing Monte Carlo simulation parameters for a reproducible dose-averaged linear energy transfer10.1259/bjr.20200122 ↗
18. An analysis of MCNP cross-sections and tally methods for low-energy photon emitters10.1088/0031-9155/47/8/307 ↗
19. The FLUKA code: Description and benchmarking10.1063/1.2720455 ↗
20. Implementation of FLUKA for γ-ray applications in the marine environment10.1016/j.jenvrad.2016.08.008 ↗
21. Inter-comparison of dose distributions calculated by FLUKA, GEANT4, MCNP, and PHITS for proton therapy10.1051/epjconf/201715304011 ↗
22. Shielding design for high-intensity Co-60 and Ir-192 gamma sources used in industrial radiography based on PHITS Monte Carlo simulations10.1140/epjp/s13360-020-00797-8 ↗
23. Monte Carlo simulation of X-ray room shielding in diagnostic radiology using PHITS code
24. Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C10.1088/0031-9155/49/21/004 ↗
25. Simulation of a complete X-ray digital radiographic system for industrial applications10.1016/j.apradiso.2018.05.017 ↗
26. Advances and researches on non destructive testing: A review10.1016/j.matpr.2017.11.620 ↗
27. A Comparison of in vivo Cellular Responses to CS-137 Gamma Rays and 320-KV X Rays10.2203/dose-response.12-050.Scott ↗
28. Concrete density estimation of linac bunker walls using impact-echo testing10.1016/j.ejmp.2020.08.001 ↗
29. Radiation attenuation on labyrinth design bunker using Iridium-192 source10.1063/1.4972945 ↗
30. Evaluation of the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels using particle and heavy ion transport code system: PHITS10.1016/j.apradiso.2017.07.028 ↗