The use of micro-computed tomography (micro-CT) has become widespread in the examination of dental tissue due to its great precision in small-scale work. Its usefulness in measuring tissue mineral density has been demonstrated; however, it is necessary to develop image acquisition protocols that ensure the reproducibility of observations and offer a detailed step-by-step process. This study proposes a standardised protocol to quantify mineral density using volumetric measurements from micro-CT images, evaluating the reproducibility of density measurements at different points of enamel and dentine. The sample comprised 30 bovine incisors that were scanned using a micro-CT system. Using the MIMICS software v.26, seven reference points in enamel and dentine (crown, cervix, and root) were identified, and mineral density was calculated by using Hounsfield units. The reproducibility of the measurements among the three observers was assessed by calculating Lin’s concordance correlation coefficient (CCC). There was substantial to almost perfect correlation for the enamel (CCC = 0.986–0.995) and dentine (CCC = 0.965–0.997), with the latter showing better results for the cervix (CCC = 0.987–0.997) and crown (CCC = 0.987–0.995) compared with the root (CCC = 0.965–0.985). In the lingual area, the concordance results were broader (CCC = 0.965–0.997) compared with the buccal area (CCC = 0.979–0.995). Despite this difference, the proposed volumetric measurements reached a high level of agreement, which demonstrates the replicability of the present protocol.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Radiography and Imaging · Advanced X-ray and CT Imaging · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Programa de Magíster en Odontología, Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile
Centro de Investigación en Odontología Legal y Forense-CIO, Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile
Independent Researcher, Coyhaique 5950591, Chile
Departamento de Antropología, Facultad de Ciencias Sociales, Universidad de Chile, Santiago 6850331, Chile
Funding
Agencia Nacional de Investigación y Desarrollo (ANID) of Chile · ANID-Subdirección de Capital Humano/Magíster Nacional
References (62)
Show source-provided references
1. Computed Tomography versus Plain Radiography to Screen for Cervical Spine Injury: A Meta-Analysis10.1097/01.TA.0000162138.36519.2A ↗
2. Quantitative High Contrast X-Ray Microtomography for Dental Research10.1016/j.jdent.2013.01.010 ↗
3. What Is the Future of Imaging in Forensic Practice?10.1016/j.radi.2011.03.002 ↗
4. Bibliowicz, J., Khan, A., Agur, A., and Singh, K. (2011). High-Precision Surface Reconstruction of Human Bones from Point-Sampled Data, Autodesk Inc.
5. Quantitative Evaluation of the Accuracy of Micro-Computed Tomography in Tooth Measurement10.1002/ca.20265 ↗
6. Quantification of Periapical Bone Destruction in Mice by Micro-Computed Tomography10.1177/00220345000790010401 ↗
7. Present and Future in the Use of Micro-CT Scanner 3D Analysis for the Study of Dental and Root Canal Morphology
8. Three-Rooted Premolar Analyzed by High-Resolution and Cone Beam CT10.1007/s00784-012-0839-5 ↗
9. Accuracy of Segmentation of Tooth Structures Using 3 Different CBCT Machines10.1016/j.oooo.2016.09.005 ↗
10. Hard-Tissue Debris Accumulation Analysis by High-Resolution Computed Tomography Scans10.1016/j.joen.2009.04.026 ↗
11. State of the Art of Micro-CT Applications in Dental Research10.4248/IJOS09031 ↗
12. Martin-Frances, L., Martinoon-Torres, M., Martínez de Pinillos, M., Garcia-Campos, C., Modesto-Mata, M., Zanolli, C., Rodrguez, L., and De Castro, J.M.B. (2018). Tooth Crown Tissue Proportions and Enamel Thickness in Early Pleistocene Homo Antecessor Molars (Atapuerca, Spain). PLoS ONE, 13.10.1371/journal.pone.0203334 ↗
13. Dimorphism in Dental Tissues: Sex Differences in Archaeological Individuals for Multiple Tooth Types10.1002/ajpa.24174 ↗
14. Contribution of Dental Tissues to Sex Determination in Modern Human Populations10.1002/ajpa.23447 ↗
15. Modern Humans Sex Estimation through Dental Tissue Patterns of Maxillary Canines10.1002/ajpa.23715 ↗
16. High-Biofidelity Biomodel Generated from Three-Dimensional Imaging (Cone-Beam Computed Tomography): A Methodological Proposal
17. An Anatomic Investigation of the Mandibular First Molar Using Micro-Computed Tomography10.1016/j.joen.2013.06.034 ↗
18. A Micro-Computed Tomographic (Micro-CT) Analysis of the Root Canal Morphology of Maxillary Third Molar Teeth10.1016/j.aanat.2017.09.003 ↗
19. A Simple Rocker-Induced Mechanical Stimulus Upregulates Mineralization by Human Osteoprogenitor Cells in Fibrous Scaffolds10.1002/term.2462 ↗
20. Hong, J., Kim, U., and Yeo, I. (2022). Comparison of Three-Dimensional Digital Analyses and Two-Dimensional Histomorphometric Analyses of the Bone-Implant Interface. PLoS ONE, 17.10.1371/journal.pone.0276269 ↗
21. Rawson, S., Maksimcuka, J., Withers, P., and Cartmell, S. (2020). X-Ray Computed Tomography in Life Sciences. BMC Biol., 18.10.1186/s12915-020-0753-2 ↗
22. X-Ray Microtomography: Nondestructive Three-Dimensional Imaging for in Vitro Endodontic Studies10.1016/S1079-2104(97)90155-4 ↗
23. Microcomputerised Tomography Evaluation of 10% Carbamide Peroxide Applied to Enamel10.1016/j.jdent.2004.12.001 ↗
24. Thirty-Five Percent Carbamide Peroxide Application Causes in Vitro Demineralization of Enamel10.1016/j.dental.2006.06.032 ↗
25. A Quantitative Study of the Effect of Pumicing and Etching on the Remineralisation of Enamel Opacities10.1046/j.1365-263X.2001.00267.x ↗
26. Evaluation of Voxel Values in Mandibular Cancellous Bone: Relationship between Cone-Beam Computed Tomography and Multislice Helical Computed Tomography10.1111/j.1600-0501.2008.01672.x ↗
27. Bone Density: Comparative Evaluation of Hounsfield Units in Multislice and Cone-Beam Computed Tomography10.1590/S1806-83242012000600011 ↗
28. A Guide to Accurate Reporting in Digital Image Acquisition—Can Anyone Replicate Your Microscopy Data?10.1242/jcs.254144 ↗
29. Optimization of SPECT/CT Imaging Protocols for Quantitative and Qualitative 99mTc SPECT10.1186/s40658-021-00405-3 ↗
30. Arango-Santander, S., Montoya, C., Pelaez-Vargas, A., and Ossa, E. (2020). Chemical, Structural and Mechanical Characterization of Bovine Enamel. Arch. Oral Biol., 109.10.1016/j.archoralbio.2019.104573 ↗
31. Morphological Analysis of Human and Bovine Dentine by Scanning Electron Microscope Investigation10.1016/j.archoralbio.2007.09.005 ↗
32. Comparative Analysis of Root Dentin Morphology and Structure of Human Versus Bovine Primary Teeth10.1017/S1431927615000434 ↗
33. Bovine Tooth Is a Substitute for Human Tooth on Bond Strength Studies: A Systematic Review and Meta-Analysis of in Vitro Studies10.1016/j.dental.2016.09.019 ↗
34. A Review of the Structure of Human and Bovine Dental Hard Tissues and Their Physicochemical Behaviour in Relation to Erosive Challenge and Remineralisation10.1016/j.jdent.2011.01.008 ↗
35. Structural Differences in Enamel and Dentin in Human, Bovine, Porcine, and Ovine Teeth10.1016/j.aanat.2017.12.012 ↗
36. A Concordance Correlation Coefficient to Evaluate Reproducibility10.2307/2532051 ↗
37. Overall Concordance Correlation Coefficient for Evaluating Agreement among Multiple Observers10.1111/j.0006-341X.2002.01020.x ↗
38. A Proposal for Strength-of-Agreement Criteria for Lin’s Concordance Correlation Coefficient
39. Inter- and Intraobserver Reproducibility of Buccal Bone Measurements at Dental Implants with Cone Beam Computed Tomography in the Esthetic Region10.1186/s40729-015-0007-1 ↗
40. Guidelines for Reproducing Geometrical Aspects of Intra-Oral Radiographs Images on Cone-Beam Computed Tomography10.1016/j.forsciint.2016.12.015 ↗
41. Kochhar, A., Sidhu, M., Prabhakar, M., Bhasin, R., Kochhar, G., Dadlani, H., Spagnuolo, G., and Mehta, V. (2021). Intra- And Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography. Dent. J., 9.10.3390/dj9020014 ↗
42. Can Gray Values Be Converted to Hounsfield Units? A Systematic Review10.1259/dmfr.20210140 ↗
43. Effects of Image Artifacts on Gray-Value Density in Limited-Volume Cone-Beam Computerized Tomography10.1016/j.tripleo.2006.12.005 ↗
44. Density Estimation Based on the Hounsfield Unit Value of Cone Beam Computed Tomography Imaging of the Jawbone System10.1177/0954411918806333 ↗
45. The Density and Branching of Dentinal Tubules in Human Teeth10.1016/0003-9969(96)00008-8 ↗
46. Dentin Tubule Numerical Density Variations below the CEJ10.1016/j.jdent.2008.08.002 ↗
47. Towle, I., Salem, A., Veneziano, A., and Loch, C. (2023). Variation in Enamel and Dentine Mineral Concentration and Density in Primate Molars. Arch. Oral Biol., 153.10.1016/j.archoralbio.2023.105752 ↗
48. Campioni, I., Pecci, R., and Bedini, R. (2020). Ten Years of Micro-CT in Dentistry and Maxillofacial Surgery: A Literature Overview. Appl. Sci., 10.10.3390/app10124328 ↗
49. Dientes de Bovino Como Sustituto de Dientes Humanos Para Su Uso En La Odontología. Revisión de Literatura
50. Sisson, S., Grossman, J., and Getty, R. (1975). Digestive System of the Ox. The Anatomy of the Domestic Animals, Saunders Co.
51. Bovine Teeth as Possible Substitutes in the Adhesion Test10.1177/00220345830620101501 ↗
52. Comparison of the Number and Diameter of Dentinal Tubules in Human and Bovine Dentine by Scanning Electron Microscopic Investigation10.1016/S0003-9969(00)00006-6 ↗
53. Comparison of the in Vivo Effect of a 0 and 1,500 PpmF MFP Toothpaste on Fluoride Uptake, Acid Resistance and Lesion Remineralization10.1159/000260935 ↗
54. Topographical, Diametral, and Quantitative Analysis of Dentin Tubules in the Root Canals of Human and Bovine Teeth10.1016/j.joen.2006.12.011 ↗
55. The Potential of Deciduous and Permanent Bovine Enamel as Substitute for Deciduous and Permanent Human Enamel: Erosion-Abrasion Experiments10.1016/j.jdent.2007.07.007 ↗
56. Viability of Using Enamel and Dentin from Bovine Origin as a Substitute for Human Counterparts in an Intraoral Erosion Model10.1590/S0103-64402010000400008 ↗
57. Is Bovine Dentine an Appropriate Substitute for Human Dentine in Erosion/Abrasion Tests?10.1111/j.1365-2842.2007.01843.x ↗
58. In Vitro Assessment of the Tooth Staining Potential of Endodontic Materials in a Bovine Tooth Model10.1111/edt.12285 ↗
59. Effect of PH Conditioners on Tooth Bleaching10.1002/cre2.172 ↗
60. Efficacy of Different Whitening Modalities on Bovine Enamel and Dentin10.1007/s00784-004-0291-2 ↗
61. Effect of Thermal Cycling on Bond Strengths of Single-Step Self-Etch Adhesives to Bovine Dentin10.2334/josnusd.48.63 ↗
62. Bond Strength of Adhesive Systems to Dentin and Enamel-Human vs. Bovine Primary Teeth in Vitro10.1016/j.dental.2007.11.003 ↗