Pedestrian Comfort Analysis and Parameterized Optimization Design for Raised Floors
Source abstract
Abstract
Pedestrian comfort is not only related to the health of the human body, but also directly impacts the efficiency and lifespan of building materials. Raised floors have more complex geometric characteristics and structural dynamic properties compared to traditional flooring, which necessitates an analysis of pedestrian comfort. This study explores four different configurations of raised floors in prefab bathroom units to evaluate their pedestrian comfort. Through theoretical and experimental modal analysis, the natural frequencies and potential deformation areas are identified, enabling the calculation of peak acceleration of the raised floors under walking excitation. The study then quantitatively assesses the pedestrian comfort of raised floors based on natural frequency and peak acceleration measurements, proposing an optimization design method using a multi-island genetic algorithm (MIGA). By adjusting parameters such as the support leg distance, beam shape, and support board surface layer thickness, an optimal balance between pedestrian comfort and heat transfer performance is achieved. Through the integration of simulation and experimental techniques, the study presents an efficient and cost-effective optimization design method for raised floors and explores the impact mechanism between design variables and pedestrian comfort performance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Engineering and Vibration Analysis · Railway Engineering and Dynamics · Urban and spatial planning
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Architecture, Tianjin University, Tianjin 300072, China
School of Future Technology, Tianjin University, Tianjin 300072, China
Beijing Weishi Living Technology Co., Ltd., Beijing 100000, China
References (46)
Show source-provided references
1. Comparing Carbon Emissions of Precast and Cast-in-Situ Construction Methods—A Case Study of High-Rise Private Building10.1016/j.conbuildmat.2015.08.145 ↗
2. Structural Behavior and Vibration Characteristics of Geopolymer Composite Lightweight Sandwich Panels for Prefabricated Buildings10.1016/j.jobe.2022.104872 ↗
3. Environmental Life Cycle Evaluation of Prefabricated Residential Construction in China10.1016/j.jobe.2022.104776 ↗
4. Anson, M., Ko, J.M., and Lam, E.S.S. (2002). Raised Floor System: A Paradigm of Future Office Building Fitout?. Advances in Building Technology, Elsevier.
5. Applications and Experimentations of the Prefabricated Infill System in Refurbishing Existing Housing: Design Solutions
6. Vibration Serviceability of Hybrid CLT-Steel Composite Floors Based on Experimental and Numerical Investigations Using Random Walk Models10.1016/j.engstruct.2024.117600 ↗
7. Sensitivity of Human-Induced Vibrations and Comfort Analysis to Partially Rigid STS Joints in Timber-to-Timber Composite Floors10.1016/j.measurement.2024.114396 ↗
8. Human-Induced Vibrations of Floors: A Probabilistic Approach10.1016/j.engstruct.2023.117198 ↗
9. (2018). General Specification for Raised Access Floor for Electrostatic Protection (Standard No. GB/T 36340-2018).
10. Standardization study of the overhead floor system
11. Dynamic Thermal Characterization of Raised Floor Plenum Data Centers: Experiments and CFD10.1016/j.jobe.2019.100783 ↗
12. Airflow Distribution through Perforated Tiles in Raised-Floor Data Centers10.1016/j.buildenv.2005.03.005 ↗
13. Case Study Regarding the Thermal Environment and Energy Efficiency of Raised-Floor and Row-Based Cooling10.1016/j.buildenv.2020.107110 ↗
14. An Experimental Study on the Influences of Air Change Rate and Free Area Ratio of Raised-Floor on Cleanroom Particle Concentrations10.1016/j.buildenv.2011.09.001 ↗
15. Predictive Modeling of Thermal Parameters inside the Raised Floor Plenum Data Center Using Artificial Neural Networks10.1016/j.jobe.2021.102397 ↗
16. Status of Vibration Serviceability Design Methods for Lightweight Timber Floors10.1016/j.jobe.2022.104111 ↗
17. Experimental Study on the Vibration of Poplar LVL Orthogonal Ribbed Box Floor10.1016/j.jobe.2022.105564 ↗
18. Vibration Behavior of Timber-Concrete Composite Floors under Human-Induced Excitation10.1016/j.jobe.2020.101744 ↗
19. Full Scale Testing of Timber-Concrete Composite Floors in an Overhanging Configuration10.1016/j.engstruct.2023.116460 ↗
20. The Effect of Shear Connectors on the Strength, Serviceability and Dynamic Response of Composite Floors Using Cold-Formed Steel Beams and Concrete in Decking10.1016/j.engstruct.2022.114806 ↗
21. Dynamic Testing and Numerical Simulation of Human-Induced Vibration of Cantilevered Floor with Tuned Mass Dampers10.1016/j.istruc.2021.08.079 ↗
22. Vibration Properties of a Timber Floor Assessed in Laboratory and during Construction10.1016/j.engstruct.2014.10.019 ↗
23. Interaction between Walking Humans and Structures in Vertical Direction: A Literature Review
24. A Spectral Load Model for Pedestrian Excitation Including Vertical Human-Structure Interaction10.1016/j.engstruct.2017.11.050 ↗
25. Vertical Ground Reaction Forces on Rigid and Vibrating Surfaces for Vibration Serviceability Assessment of Structures10.1016/j.engstruct.2018.06.059 ↗
26. Pedestrian-Induced Lateral Vibrations of Footbridges: A Literature Review10.1016/j.engstruct.2012.05.038 ↗
27. Measurement and Application of Walking Models for Evaluating Floor Vibration10.1016/j.istruc.2023.02.073 ↗
28. Use of Pressure Insoles to Calculate the Complete Ground Reaction Forces10.1016/j.jbiomech.2003.12.016 ↗
29. Review of Studies on Long-span Floor Serviceability
30. Application of Expanded Polystyrene (EPS) in Buildings and Constructions: A Review10.1002/app.47529 ↗
31. Investigation of the Effects of Different Types of Interlayers on Floor Impact Sound Insulation in Box-Frame Reinforced Concrete Structures10.1016/j.buildenv.2014.03.008 ↗
32. Flexural Behaviors of Concrete/EPS-Foam/Glass-Fiber Composite Sandwich Panel10.1155/2018/5286757 ↗
33. Seo, H.J., Park, J.S., Bae, K.S., and Oh, S.K. Applicability on Water Treatment Structure of Anti-corrosive Sheet Molding Compound Panel. Proceedings of the Korean Institute of Building Construction Conference 2011, Seoul, Republic of Korea.
34. Research on pedestrian vibration comfort of building structure
35. (2010). Code for design of concrete structures. Standard No. GB50010-2010.
36. (2010). Technical specification for concrete structures of tall building. Standard No. JGJ 3-2010.
37. (2015). Technical specification for steel structure of tall building. Standard No. JGJ 99-2015.
38. (2016). Design Guide 11: Vibrations of Steel-Framed Structural Systems Due to Human Activity, American Institute of Steel Construction. [2nd ed.].
39. (2002). Eurocode 2: Design of Concrete Structures—Part 2: General Rules and Rules for Buildings (Standard No. En.1990.2002).
40. Nguyen, H. (2013). Walking Induced Floor Vibration Design and Control. [Ph.D. Thesis, Swinburne University of Technology].
41. Influence of Body Weight Support on Normal Human Gait: Development of a Gait Retraining Strategy10.1093/ptj/71.11.842 ↗
42. Experimental Identification and Analytical Modelling of Human Walking Forces: Literature Review10.1016/j.jsv.2009.04.020 ↗
43. Effects of Obesity and Sex on the Energetic Cost and Preferred Speed of Walking10.1152/japplphysiol.00767.2005 ↗
44. (2016). Code for Thermal Design of Civil Building (Standard No. GB50176-2016).
45. Nonlinear Rotational Inertial Double-Tuned Mass Damper for Reducing Human-Induced Floor Vibration with Frequency Detuning10.1016/j.ymssp.2022.109016 ↗
46. Implementation Considerations for Active Vibration Control in the Design of Floor Structures10.1016/j.engstruct.2012.05.034 ↗